3.  Place a shop rag beneath the fuel pump to catch any

spilled fuel oil, and then remove the fuel pump cover.
To do this, use a 4-mm Allen wrench to remove the 
four bolts that secure the cover to the fuel 
pump/blower assembly. 

Remove the fuel pump cover 

4.  Remove the fuel pump screen.

Remove the fuel pump screen 

5.  Inspect the screen for damage. If the screen is not 

damaged, proceed to step 6. If the screen is bent,
torn, cracked, or damaged in any way, discard it and 
skip to step 7 with a new fuel pump screen.

6.  Rinse the screen in the 1/4 cup of clean fuel oil. If 

necessary, gently scrub the screen with the nylon-
bristled brush (a toothbrush works well) to remove
any debris or buildup.

7.  Replace the screen and fuel pump cover. Tighten the

bolts snugly. Wipe up any spilled fuel oil from the 
housing or fuel pump. 

8.  Reopen the fuel line shut-off valve by turning the red 

knob counter-clockwise.

9.  Before replacing the housing cover, check for leaks

around the pump cover during operation. To do this, 
set up the Dragon outside and allow to run in HEAT 
mode for several minutes. If the fuel pump cover does
not leak, proceed to step 9.

If the fuel pump cover leaks, turn off and unplug unit 
before attempting to tighten or reseal the cover. If the 
cover will not stop leaking, have the unit inspected at 
a qualified service center.

10. Reattach the housing cover and guard plate. 

Cleaning the Dragon 

The heat exchanger and combustion chamber should
be cleaned at least once a year to remove soot 
buildup.
The cleaning should be performed by a qualified
HVAC technician at a local service center. Contact
your local distributor or the Dri-Eaz Service
Department at 1-888-867-3235 for the location of a 
service center near you. 

To clean the Dragon housing, use a cleaner with a 
degreasing agent similar to Simple Green

®

.

07-00407F  02/2008

12

Copyright 2006 Dri-Eaz Products, Inc. 

Содержание Dragon K85 Mobile

Страница 1: ...damage to the unit It may also void the Dri Eaz warranty Altitude Adjustment NOTICE The Dragon is factory set for use at elevations up to 2000 feet above sea level For use above 2000 feet or for any...

Страница 2: ...n mind there are some general principles to keep in mind when using the Dragon You should try to stabilize the temperature of the affected area near the ideal operating temperature of your drying equi...

Страница 3: ...ace the unit on a level stable surface Choose an inconspicuous location away from high traffic areas for children and or pets Ensure there is no obstruction in the air intake during the use of the Dra...

Страница 4: ...be approximately 90 degrees apart Drill two 1 8 inch holes in the flue 3 Drive a sheet metal screw 8x1 through each hole to secure the flue to the Dragon Secure the flue to the Dragon with sheet meta...

Страница 5: ...lable at most hardware stores into the hole in the plywood Secure the duct adapter to the plywood 4 Slip a hose clamp not included over the free end of one of the 30 foot lengths of 8 inch diameter al...

Страница 6: ...hole will do 3 Place a TurboDryer Vortex Axial Fan or other airmover so that it forces air out of the affected area to the outdoors through the selected opening The airmover should remove at least 800...

Страница 7: ...example with a setpoint of 85 F the Dragon will stop heating when the temperature exceeds 85 F Use the arrows to choose a setpoint Use the arrows to choose a setpoint 3 Press the SET key again to acc...

Страница 8: ...ed airflow To help prevent thermal overload you should x Make ducting runs as straight as possible x Keep the ducting free of debris and unobstructed x Keep the air intake grill unobstructed Restartin...

Страница 9: ...event moisture or contaminants from getting into fuel Connecting an external fuel tank WARNING Diesel fuel is flammable and potentially explosive Always turn off and unplug the Dragon before switching...

Страница 10: ...f you are ventilating spaces adjacent to living areas you must still create a negative pressure in the affected area This will help prevent contaminants from being forced into clean areas See the sect...

Страница 11: ...voir during operation To do this set the Dragon up outside and allow to run in HEAT mode for several minutes If the reservoir does not leak proceed to step 9 If the reservoir leaks turn off and unplug...

Страница 12: ...ne shut off valve by turning the red knob counter clockwise 9 Before replacing the housing cover check for leaks around the pump cover during operation To do this set up the Dragon outside and allow t...

Страница 13: ...em Flame Safety Control Button will illuminate FS Wait one minute and then press the illuminated Flame Safety Control Button Air bubbles in fuel oil line especially on first start up FS Press the Flam...

Страница 14: ...ervice center or HVAC specialist Black white exhaust Air intake vents are dirty or obstructed AST Avoid setting up unit where the intake could be blocked or restricted i e tall grass deep snow etc Blo...

Отзывы: