DRI-AIR
INDUSTRIES, INC.
OPERATING MANUAL - ARID-X , HP4-X 18-100 FM DRYERS
Revision 10/8/02
Page 10
For all Dri-Air models except ARID-X 10, AHM-1, & PDII
Electrical Connection:
Open electrical access door on the front of the machine by
turning the disconnect off and turning the lower clamping
screw 1/2 turn counterclockwise. Locate the disconnect by
following the operating handle down to the electrical panel.
Insert the incoming power cable or conduit through the hole
provided on the side of the machine.
«
use approved wire and fastening means
«
Wire incoming power to the top of the disconnect as shown in
the diagrams below.
NOTE:
When 3 wire supplies are used in place of 4 wire supplies,
a control transformer is required.
3 PHASE DRYER INSTALLATION
CHECK FOR CORRECT MOTOR ROTATION
BEFORE RUNNING DRYER
To check motor rotation.......
Leave the electrical cabinet door open so the blower can be
observed. Turn on the power to the dryer and press the ON/
START touch pad and then immediately press the OFF/STOP
touch pad. Observe the cooling fan on the top of the blower
motor and verify the fan is turning clockwise. If the motor is
not turning clockwise, switch any two adjacent supply wires.
The unit is now ready for operation.
INSTALLATION
PROCEDURE
XX
Содержание ARID-X
Страница 18: ...DRI AIRINDUSTRIES INC OPERATING MANUAL ARID X HP4 X 18 100 FM DRYERS Revision 10 8 02 Page 18 NOTES...
Страница 19: ...DRI AIRINDUSTRIES INC OPERATING MANUAL ARID X HP4 X 18 100 FM DRYERS Revision 10 8 02 Page 19 NOTES...
Страница 20: ...DRI AIRINDUSTRIES INC OPERATING MANUAL ARID X HP4 X 18 100 FM DRYERS Revision 10 8 02 Page 20 NOTES...