CESAR 1312 (E)
Communication Interfaces
4-55
CESAR™ 1312 Generator
In the packet, bytes 1, 2, and 3 comprise the “data field” and contain
information defined by the command. Note that when the information extends
over more than one byte, the packet sends the least significant byte (LSB)
before the most significant byte (MSB).
PROFIBUS Upload Packet
During every PROFIBUS data exchange, the CESAR generator supplies a 14-
byte response to a download (“outbytes”) packet.
lists the
response or “upload packet.” These bytes are also known as “inbytes.”
Table 4-10. Configuration of upload packet (inbytes)
Byte
Description
0
Status flags—first byte
1
Status flags—second
byte
2
Delivered power low
3
Delivered power high
4
Forward power low
5
Forward power high
6
Reflected power low
7
Reflected power high
8
Data byte (LSB)
9
Data byte
10
Data byte
11
Data byte
12
Data byte (MSB)
13
Data field definition
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...