Dresser Model 10C25 Series K Installation, Operation, and Maintenance Manual
© 2018 Natural Gas Solutions North America, LLC
Page 37 of 74
12.4.2
Digital Index Removal
Perform the following steps to remove the digital index from the meter:
1.
Remove tamper evident devices, as needed.
2.
Remove screws that attach the digital index to
the meter.
Figure 36: Remove the screws that attach the
digital index to the meter
3.
Gently pull the digital index forward to remove
it from the meter.
Figure 37: Remove the digital index
4.
If needed, remove and unplug the temperature probe from the connector on the digital index.
Note:
Unplugging the temperature probe generates a temperature fault (T FLT).
For information about clearing faults, refer to Section 11.5.