Dream Catcher ME3100 Скачать руководство пользователя страница 20

         http://dreamcatcher.asia/cw 

 

 

 

 

 

 

 

 

 

 

              [email protected] 

 
ME3100 Analog Circuit Design 
 

 

Quick Start Guide - 20/25 

      

                     

                                                        

 

Keysight Measurement Manager Soft Front Panel (Oscilloscope)

 

 

 

Figure D-86 

– Soft Front Panel of the Oscilloscope 

 

Figure 

D-86

D-8  shows  the  graphic  user  interface  of  Keysight  Modular  Oscilloscope  under  Keysight 

Measurement  Manager  together  with  the  label  of  each  panel.  Table 

D-

D-4  shows  the  features  of  each 

panel of the interface. 

Table D-4 

– Features of the AMM Oscilloscope Interface 

 

No. 

Panel 

Description 

Oscilloscope toolbar 

Consists of oscilloscope tools 

Waveform Acquisition tab 

Displays the time-domain waveform for the oscilloscope 

FFT Analysis tab 

Displays the FFT spectrum of the signal 

Configuration summary 

Displays the configured functions and settings 

Waveform graph display 

Displays the output of the data acquired 

Scope control tabs 

Consists of all the sub functions of the oscilloscope 

Measurement Results panel 

Displays the measurement results of the scope operations 

Status tab 

Displays the status panel, which shows the history of operations 

Refresh rate 

Displays the graph update rate in frame/sec. 

10 

Video Sampling Rate 

Displays the video sampling rate (in number of samples per second taken from a 
continuous signal) 

11 

Calibration Delta Temp. indicator 

Displays the calibration delta temperature of the connected device 

 

Analog Controls 

 
The  analog  control  panel  of  the  interface  consists  of  a  vertical  control  and  a  horizontal  control  that  are 
used  to  control  and  set  the  waveform  of  the  graph  display.  The  vertical  control  is  used  to  change  the 

Содержание ME3100

Страница 1: ...ME3100 Analog Circuit Design Ready to Teach Package for Electronic Instrumentation and Measurement Quick Start Guide revision 2 00 Printed on 29 June 2016...

Страница 2: ...the requirements of the Low Voltage Directive 73 23 EEC and EMC Directive 89 336 EEC and carries the CE marking CAUTION ESD THIS PRODUCT CONTAINS ELECTRONIC COMPONENTS SENSITIVE TO ELECTROSTATIC DISCH...

Страница 3: ...Design Quick Start Guide 3 25 Table of Contents Table of Contents 3 1 Quick Setup and Verification 4 2 Support and Warranty 9 Appendix A ME3100 Analog Circuit Design Kit 10 Appendix B Specifications...

Страница 4: ...erted into the Embedded Audio Sound Module M1 that is located at the left corner of the ME3100 Analog Circuit Design kit 3 Turn on the power supply unit Set one of the dual channel output voltages to...

Страница 5: ...iding a constant voltage supply to the ME3100 Analog Circuit Design kit 10 If the CC annunciator is on disable the power supply output Check if this is due to a current limit setting or a faulty conne...

Страница 6: ...o the appendix for the pin layout of the op amp LM158 Figure 4 Single Band Equalizer with VU Meter 2 Table 1 shows the value of the electronics components in the schematic Table 1 Value of Components...

Страница 7: ...ith VU Meter 3 Table 2 shows the value of the electronics components of the schematic Table 2 Value of Components Label Value R1 1 5 k RF 120 k RL 330 CF1 560 nF CF2 2 2 F CF3 150 nF CL1 1 2 nF CL2 4...

Страница 8: ...n the microSD memory card The LED D1 will be turned on when the module is playing the audio file 8 The LEDs D2 D9 of the UV meter will visualize the output of the equalizer when the audio file is play...

Страница 9: ...hipment be free from defects in material and workmanship and will conform to Acehub Vista Sdn Bhd s applicable specifications If Acehub Vista Sdn Bhd receives notice of a defect or non conformance dur...

Страница 10: ...E3100 Analog Circuit Design Kit As shown in Figure A 1 the ME3100 Analog Circuit Design kit consists of the following Audio Speaker Embedded Audio Player LED Audio UV Meter Analog Potentiometer Seven...

Страница 11: ...ETY This product is rated for indoor use only EMC IEC 61326 1 2005 EN 61326 1 2006 Canada ICES NMB 001 Issue 4 June 2006 Australia New Zealand AS NZS CISPR 11 2004 DIMENSIONS W x H x D 230 mm x 65 mm...

Страница 12: ...http dreamcatcher asia cw cw enquiry dreamcatcher asia ME3100 Analog Circuit Design Quick Start Guide 12 25 Appendix C Pin Layout of LM158 Figure C 1 Pin Layout of LM158...

Страница 13: ...the U2741A there are two LED indicators The power indicator lights up once the U2741A is powered on There is a system error if the indicator blinks after the U2741A is powered on The USB indicator wil...

Страница 14: ...ltage measurement Measuring DC Current 1 The DC current measurement function of the U2741A has the following features three ranges to select 10 mA 100 mA 1 A and 2 A or auto range input impedance is 1...

Страница 15: ...function generator after the desired parameters are set 14 The U2761A is able to output five standard waveforms that are Sine Square Ramp Triangle Pulse and DC 15 You can select one of the three built...

Страница 16: ...the interface Table D 2 Features of the AMM Function Generator Interface No Panel Features 1 Waveform Pattern Selection Select various types of output function by clicking the buttons 2 Waveform Para...

Страница 17: ...e in Vrms Duty Cycle Limitations For Square waveforms the U2761A may not be able to use the full range of duty cycle values at higher frequencies as shown below 20 to 80 frequency 10 MHz 40 to 60 freq...

Страница 18: ...specify the output amplitude in dBm if the output termination is currently set to high impedance The units are automatically converted to Vpp You may configure the output termination by clicking Tool...

Страница 19: ...the PC using a USB cable 2 Power on the oscilloscope 3 Launch the Keysight IO Control and the Keysight Measurement Manager AMM 4 The Select USB Device dialog box will appear displaying the connected U...

Страница 20: ...the signal 4 Configuration summary Displays the configured functions and settings 5 Waveform graph display Displays the output of the data acquired 6 Scope control tabs Consists of all the sub functio...

Страница 21: ...below Figure D 107 Channel On Off Mode 3 The channel options provide four types of adjustment to the channel waveform these options are AC Coupling Invert BW Limit and Attenuation 1X 10X 100X You may...

Страница 22: ...ase Delay and Mode for the horizontal scale adjustment This is shown in Figure D 13813 Figure D 138 Soft Front Panel of the Horizontal System Controls 9 Time base allows you to control how often the v...

Страница 23: ...n the toolbar of the soft front panel 2 Click to activate the automated measurement and cursor system This will display the window as shown below Figure D 16 Soft Front Panel of the Measurement and Cu...

Страница 24: ...Stop 1 AutoScale automatically configures the oscilloscope to best display the input signal by analyzing any waveforms connected to the channel and external trigger inputs If AutoScale fails your curr...

Страница 25: ...tronic mechanical photocopying recording or otherwise without prior written permission of Acehub Vista Sdn Bhd Every effort has been made to ensure that the information in this manual is accurate Aceh...

Отзывы: