20
- VCA (2) OUT to a monitor
- LFO OUT to VCA (2) CV
- LFO RATE at 50%
- LFO LVL at max
- VCA (2) INIT at 50%
Observe the signal's opening and closing to the LFO rate.
- Remove the LFO OUT from VCA(2) CV and set INIT at max.
Observe a constant signal .
-Follow the exact above process for VCA(3)
12.
Remove all patch cables and now connect:
- OSCILLATOR SQU to a monitor
- LFO OUT to MULTI IN
- MULTI OUT (any channel) to OSCILLATOR CV IN and observe the change of the pitch.
- Check all MULTI OUT channels
The Check is now complete!