background image

15

LETDOWN and EXPRESSION MODE:

Letdown Mode

 is used to stimulate the release of milk from the breast. This mode mimics 

baby’s way of rapidly sucking at the beginning of a breastfeeding session, prompting the reflex 

that releases breast milk.

Expression Mode

 is used once the breast milk has been released and is now expressing from 

the nipple. This mode mimics baby’s more relaxed feeding that happens once milk is flowing 

and draws milk more deeply from the breast.

Using Letdown Mode

:

1. Press the POWER BUTTON to turn the unit on.  
2. The pump will automatically display Letdown Mode at the last vacuum level used. 
3. Position the assembled milk collection kit on breast as directed on page 16.
4. Press the START/PAUSE BUTTON to begin pumping. The timer will begin. Press the button again at any 

time you wish to pause pumping. 
5. If needed, adjust vacuum level to your preferred starting level using the VACUUM UP and VACUUM DOWN 

BUTTONS. There are five user-selectable vacuum levels in the Letdown Mode: L1, L2, L3, L4, L5.

Adjustments to vacuum level may be made at any time while pumping - adjustments cannot be made to 

the cycle level in Letdown Mode. It may take several pumping sessions to discover your most comfortable 

and productive vacuum level.

Using Expression Mode:

1. Once letdown has begun (milk is visibly expressing from nipples), switch to Expression Mode.
2. Press the MODE SELECTOR BUTTON. The LETDOWN MODE INDICATOR symbol will disappear when in 

Expression Mode.
3. The pump will automatically display Expression Mode at the last vacuum level used. 
4. If needed, adjust cycle level (speed) to your preferred level using the CYCLE UP and CYCLE DOWN BUTTONS. 

There are five user-selectable cycle levels in the Expression Mode: 36, 40, 43, 46, 49.
5. If needed, adjust vacuum level to your preferred level using the VACUUM UP and VACUUM DOWN BUTTONS. 

There are twelve user-selectable vacuum levels in the Expression Mode: L1 through L12.
6. Once pumping is complete (breast milk is no longer expressing), simply press the POWER BUTTON to turn 

off the pump.

Adjustments to vacuum & cycle levels may be made at any time while pumping in Expression Mode. It may 

take several pumping sessions to discover your most comfortable and productive cycle and vacuum levels.

        Using the Pump

Содержание Customflow BF100

Страница 1: ...Customflow Double Electric Breast Pump with SoftShape Silicone Shields Model Number BF100 E506451...

Страница 2: ...elds tubing bottle vessel duckbill valve and other related accessories The materials used are silicone SoftShape Silicone Shields nipples membranes duckbill valves polypropylene pump body and bottle v...

Страница 3: ...s Safety Information 3 Breast Pump Components 6 Cleaning 8 Assembly 10 Using the Pump 14 Pump Help 17 Storing Feeding Breast Milk 18 Technical Data 20 Troubleshooting 21 Important Symbols 22 Disposal...

Страница 4: ...ays unplug electrical product immediately after use Do not use while bathing Do not place or store product where it can fall or be pulled into a tub or sink Do not place or drop into water or other li...

Страница 5: ...apter supplied with the breast pump Make sure the voltage of the power adapter is compatible with the power source CAUTION To avoid risk of minor injury Wash hands thoroughly with soap and water befor...

Страница 6: ...nsultant Contact your healthcare professional or lactation consultant if you can express only minimal or no milk or if expression is painful Do not try to express with vacuum that is too high and unco...

Страница 7: ...Brown s Options Bottles Narrow toWide Neck Adapter provided for use with Dr Brown sWide Neck bottles bottles not included 2 x NarrowTravel Storage Cap 1x Slowest Flow Preemie Flow Nipple 2x Narrow toW...

Страница 8: ...7 1x Customflow Double Electric Breast Pump Storage Area Bottle Holder Bottle Holder Ports Port Cover Handle 1x Silicone StretchWall Power Adapter Plug In 1x 6V Power Adapter Breast Pump Components...

Страница 9: ...unning water until all soap has been removed 6 Alternately wash all parts in the top rack of the dishwasher 7 Rest parts on a clean towel or rack to air dry 8 Sanitize sterilize before each use Microw...

Страница 10: ...3 Wash with warm soapy water and rinse clean with clear water 4 Allow water to drain from tubing completely after washing 5 Shake out any remaining water droplets and hang to dry 6 Do not use tubes u...

Страница 11: ...bled All milk contact components must be disassembled washed and sterilized prior to first use Twist membrane cap a turn and lift to remove Lift membrane from edge to remove from pump connector Pull t...

Страница 12: ...membrane and press down edges to secure Twist bottle to thread on to pump connector Wash hands before touching assembling milk collection kit All milk contact components must be disassembled washed an...

Страница 13: ...ng connects to the membrane cap Female end of tubing connects to port on front of pump TUBING To use for single sided pumping remove the tube that is no longer needed and place the port cover in the e...

Страница 14: ...de each wall column into its holder from above Foldthecord donotwrap Wrappingthecordcan breakthewires Topreventdamagetoyour poweradaptercord alwaysgraspthebodyof theadapterasshownabove Neverpullbythec...

Страница 15: ...t replacement parts Outside of the US and Canada contact your local distributor Do not try to express milk if the level of vacuum is painful this may lead to nipple and or breast trauma and cause diff...

Страница 16: ...de L1 L2 L3 L4 L5 Adjustmentstovacuumlevelmaybemadeatanytimewhilepumping adjustmentscannotbemadeto thecyclelevelinLetdownMode Itmaytakeseveralpumpingsessionstodiscoveryourmostcomfortable andproductive...

Страница 17: ...the nipple in the neck of the shield Your nipple should not touch or rub on the side walls of the shield Check nipple positioning again once the pump is operating to ensure that it remains away from t...

Страница 18: ...n Cycle levels represent the speed of the on off suction cycle How do I find my preferred cycle and vacuum levels Every mom reacts differently to cycle and vacuum levels Start low and work your way up...

Страница 19: ...an be stored safely Breast Milk Storage Guidelines Center for Disease Control and Prevention CDC https www cdc gov breastfeeding recommendations handling_breastmilk htm Adapted from ABM Clinical Proto...

Страница 20: ...refrigerator overnight or in breast milk warming machine Never thaw milk in the microwave Microwaving destroys nutrients baby needs and hot spots created in the microwave can burn baby s mouth Use mil...

Страница 21: ...ursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate...

Страница 22: ...collectionkitcomponents Checkfordamage Softshape SiliconeShieldis completelyonthebreast Checkfordamage Checkthevacuumlevel Replaceifdamaged Pressmorefirmlyagainst thebreast Replacemembraneifdamaged Ch...

Страница 23: ...type from your wall outlet This symbol indicates direct current The type required to power the pump device This symbol indicates that this device should be kept dry This symbol indicates the need for...

Страница 24: ...recycled This includes the following parts as outlined on page 6 SoftShape Silicone Shields Membrane Tubing DuckbillValve Disposal of Dr Brown s Options Bottle and Accessories The hard plastic accesso...

Страница 25: ...givesyouspecificlegalrights aswellasotherrightswhichvaryfromstatetostate WarrantyavailabletoUSandCanadianresidentsonly CustomerService Ifyouexperienceunsatisfactoryoperationorhaveanyquestions comments...

Отзывы:

Похожие инструкции для Customflow BF100