Dražice OKCE 100 S/2.2 kW Скачать руководство пользователя страница 4

- 4 -

 

 

1

 

TECHNICAL SPECIFICATION OF PRODUCT 

1.1

 

FUNCTION DESCRIPTION 

OKCE  line  water  heaters  use  only  electricity  for  heating.  Their  nominal  performance  provides  sufficient 
amount of hot water for flat units, premises, restaurants, and similar establishments. 

 

1.2

 

PRODUCT DESCRIPTION 

The  heater  tank  is  welded  from  a  steel  sheet;  it  is  entirely  coated  with  hot  water  resistant  enamel.  For 
additional corrosion protection a magnesium anode is mounted in the upper part of the heater to adjust 
the electric potential inside the tank, lowing the risk of corrosion. All types have the outlets of hot and cold 
water and a circulation opening welded to them. The tank is insulated with 65 mm of polyurethane foam. 
The heater shield consists of a steel, powder-paint coated, sheet; the connecting parts are metal coated. 
For  heaters  100  –  125  l  is  a  flange  welded  onto  the  upper  bottom  of  the  receptacle  with  a  flange  lid 
screwed to it. A sealing ring is inserted between the flange lid and the flange.  

Thermo  wells  for  the  safety  thermostat  sensors  and  capillar  thermometer  installation  are  placed  in  the 
flange  lid.  Wiring  is  placed  under  the  plastic  removable  cover.  Under  a  plastic  cover  on  the  side  of  the 
heater,  there  is  a  cleaning  and  revision  opening  ended  with  a  flange;  various  performance  heating  units 
may be mounted into the opening. The heater is to be placed on the ground. 

Tanks between 100 and 250 litres are tested with the pressure of 0.9 MPa; 300 litre tanks are tested with 
1.5 MPa. 

Содержание OKCE 100 S/2.2 kW

Страница 1: ...Pa OKCE 125 S 2 2 kW OKCE 250 S 2 2 kW OKCE 400 S 1 MPa OKCE 160 S 2 2 kW OKCE 250 S 3 6 kW OKCE 500 S 1 MPa OKCE 160 S 3 6 kW OKCE 750 S 1 MPa OKCE 200 S 2 2 kW OKCE 1000 S 1 MPa Dru stevn z vody Dra...

Страница 2: ...00 S 3 6 kW OKCE 250 S 2 2 kW OKCE 250 S 3 6 kW OKCE 300 S 1 MPa OKCE 400 S 1 MPa OKCE 500 S 1 MPa 11 2 2 4 WIRING FOR OKCE 300 S 1MPa OKCE 400 S 1 MPa OKCE 500 S 1MPa OKCE 750 S 1MPa OKCE 1000 S 1MPa...

Страница 3: ...d would like to thank you for your decision to use a product of our brand With this guide we will introduce you to the use construction maintenance and other information on electrical water heaters Th...

Страница 4: ...them The tank is insulated with 65 mm of polyurethane foam The heater shield consists of a steel powder paint coated sheet the connecting parts are metal coated For heaters 100 125 l is a flange weld...

Страница 5: ...KCE 100 S 2 2 kW OKCE 125 S 2 2 kW A 885 1050 B 885 1050 C 126 126 D 524 54 L 520 620 1 3 CONSTRUCTION AND GENERAL HEATER DIMENSIONS OKCE 100 S 2 2 kW OKCE 125 S 2 2 kW Figure 1 3 4 vn j 3 4 vnit n 1...

Страница 6: ...4 vn j 3 4 vnit n 3 4 vn j 3 4 vnit n TYPE OKCE 160 S 2 2 kW OKCE 200 S 2 2 kW OKCE 250 S 2 2 kW A 1047 1357 1537 B 966 1279 1459 C 519 859 1059 D 168 168 168 E 79 79 79 F 242 242 242 TYPE OKCE 160 S...

Страница 7: ...S 1MPa A 304 292 B 79 65 C 514 385 D 650 700 E 1194 1269 F 1289 1414 G 1790 1790 H 1920 1924 I 245 273 OKCE 300 S 1 MPa Figure 4 OKCE 400 S 1 MPa OKCE 500 S 1 MPa Figure 5 A 1578 B 724 C 79 D 650 F 75...

Страница 8: ...W OKCE 160 S 2 2 kW OKCE 200 S 2 2 kW OKCE 250 S 2 2 kW OKCE 160 S 3 6 kW OKCE 200 S 3 6 kW OKCE 250 S 3 6 kW CAPACITY l 100 125 160 220 259 WEIGHT kg 42 49 58 72 80 67 81 89 OPERATING PRESSURE OF ACC...

Страница 9: ...ulations and standards also conditions for connection defined in local electric and water works have to be adhered to as well as the installation and operation manual The temperature at the place of h...

Страница 10: ...ts of the heater is IP 45 Power input of electric element is 2000 W Figure 7 2 2 2 WIRING FOR OKCE 100 S 2 2 KW OKCE 125 S 2 2 KW Wiring scheme is attached to the heater wiring on the cover Connect re...

Страница 11: ...serted all the way in first the thermostat and then the safety fuse The performance of heating unit may be adjusted based on either required heating time or connecting possibilities of electric energy...

Страница 12: ...ostat to the snowflake sign preventing the water from freezing or turn off the inlet of electricity to the heater Connection repairs and wiring inspections may only be implemented by company person au...

Страница 13: ...kW OKCE 300 S 1 MPa OKCE 400 S 1 MPa OKCE 500 S 1 MPa TPK 210 12 5 9 kW TPK 210 12 8 12 kW Mounting 12 x M12 Figure 12 Wiring scheme Notice Factory connection must not be changed Cover of wiring with...

Страница 14: ...rconnect the clips on the 1 10 terminal board in accordance with the following schemes 3 kW 1 PE N AC 230 V 50 Hz 3 kW 2 PE N AC 400 V 50 Hz 4 kW 3 PE N AC 400 V 50 Hz 6 kW 3 PE N AC 400 V 50 Hz OKCE...

Страница 15: ...SE 377 11 SE 378 14 SE 377 16 SE 378 19 Capacity Flanges size Time of heating from 10 C to 60 C hours l Mm 8 6 5 4 3 2 5 2 1 5 300 flange 210 RDU 18 2 5 RDU 18 3 RDU 18 3 8 RDU 18 5 RDU 18 6 RDW 18 7...

Страница 16: ...ominal clearance of safety valves is defined by standard 300 l heaters are not equipped with a safety valve The safety valve must be easily accessible as close to the heater as possible The input pipe...

Страница 17: ...t pipes preventing spontaneous heater draining and hot water penetrating back into the water main We recommend that the hot water distribution from the heater was as short as possible to minimise heat...

Страница 18: ...he operating and then the safety thermostat b Open the hot water valve on the combination faucet c Open the cold water inlet valve to the heater d When the water starts flowing through the hot water v...

Страница 19: ...the company in charge of service affairs clean and exchange the anode When discharging water from the heater the mixing valve of the hot water tap must be open in order to avoid creating underpressur...

Страница 20: ...adjusted against the fixed point on the control panel Figure 19 Figure 19 Adjusting the thermostat selector to the left backstop does not mean permanent shut off of the heating element When the heater...

Страница 21: ...try to repair the failure yourselves Seek either expert or service help It does not take much for an expert to remove the defect When making a repair appointment report the type and serial number you...

Страница 22: ...use 4 2 DISPOSAL OF PACKAGING MATERIAL AND FUNCTIONLESS PRODUCT A service fee for providing return and recovery of packaging in which the water heater was delivered The service fee was paid pursuant...

Страница 23: ...o put the two zip insulation sides together Figure 19 so that the insulation does not draw down and the openings in the insulation fit the boiler inputs and outputs It must be secured that before clos...

Отзывы: