background image

 

 

and shower inserts pursuant to ČSN 332000-7-701, the appliance is provided with a grounding terminal for connecting 
with a yellow-green protective conductor on minimum section 4 mm

2

.

 

 

Access  to  the  electric  part  of  the  heater  is  enabled  only  upon  disconnecting  the  heater  from  power  supply  and 

unscrewing the guard of the heater. 
 

The degree of protection of electric parts of the heater is IP 45.  

 

Respect rules of protection against electrical injuries in accordance with ČSN 33 2000-4-41. 

 

 

10.

 

 PUTTING THE HEATER INTO OPERATION 

  

Once connected to the water and power supply, the heater can be put in service. 
Procedure: 
a)

 

check the wiring and water supply; 

check correct position of the thermostat sensors, they have to be inserted all the way.

 

The sensors must be inserted all the 

way in; first the operating and then the safety thermostat. 
b)

 

open the hot water valve on the combination faucet; 

c)

 

open the cold water inlet valve to the heater. 

d)

 

As soon as the water starts running through the hot water valve, the heater is filled and the valve closes. 

e)

 

Prior  to  putting  the  heater  into  operation,  screw  on  the  front  heater  guard  which  closes  the  access  to  the  electric 
compartment of the heater.  

f)

 

Turn on electricity using the front-end main switch which will activate the heater. 

 

11.

 

 IMPORTANT NOTICES 

 

-

 

Without a confirmation of performed electrical and plumbing fixture issued by an authorised company the 
warranty certificate shall be void. 

-

 

You have to apply for approval of a local power supplier to connect the heater. 

-

 

All hot water outlets must be provided with a combination faucet. 

-

 

It is not allowed to handle the thermostat in any manner whatsoever, aside from temperature resetting with a 
control button. 

-

 

All electric installation handling, setting, and regulation feature exchange, may only be implemented by an 
authorised service company. 

The thermal fuse must not be turned off. In case of thermostat defect, the thermal fuse interrupts electric power 
input to the heating element if the water temperature in the heater exceeds 99°C.

 

 

Disposal of packaging material and functionless product

 

A service fee for providing return and recovery of packaging material 
has  been  paid  for  the  packaging  in  which  the  water  heater  was 
delivered 
was  paid  pursuant  to  Act  No.  477/2001  Coll.,  as  amended,  at  EKO-
KOM a.s. The client number of the company is F06020274. Take the 
water  boiler  packages  to  a  waste  disposal  place  determined  by  the 
town.  When  the  operation  terminates,  disassemble  and  transport  the 
discarded  and  unserviceable  heater  to  a  waste  recycling  centre 
(collecting yard), or contact the manufacturer. 

 

  

Отзывы: