accumulate inside the heater depending on the quality, amount and temperature of the water consumed, will be removed 
as needed. During the inspection of the heating element, the service technician will advise of the date of the next 
inspection, taking into consideration the found condition of the appliance.

 

 

WARNING: Prior to any intervention in the inside of the heating element, the appliance has to be disconnected 

from power supply!

 

Do not attempt to repair the heater by yourselves, call the nearest authorised service centre to do so.

 

 

14.  INSTALLATION REGULATIONS 

 

Regulations and instructions that must be obeyed connect the heater  

a)

 

to the electrical network 

ČSN 33 2180 - Connecting of electric devices and appliances 
ČSN 33 2000-4-41 - Low voltage electric installations Protective measures to ensure safety – Protection against 
electric  shock

 

ČSN 33 2000-5-51 - Electric installations of buildings  
ČSN 33 2000-7-701 - Low voltage electric installations Single-purpose devices and devices in special premises - 
Premises with tub or shower 

 

b)

 

to the hot water heating system  

ČSN 06 0320 - Thermal systems in buildings - Hot water preparation – Design and Project Engineering

 

ČSN 06 0830 – Thermal systems in buildings – Protecting devices

 

 

ČSN 73 6660 – Internal water conduits 
ČSN 07 7401 - Water and steam for thermal energy equipments with working steam pressure up to 8 MPa 

 

ČSN 06 1010 - Tank water heaters with water and steam heating; and combined with electric heating Technical 
requirements. Testing. 

 

Both electric and water installation must follow and meet requirements and regulations relevant in the 
country of use.

 

 

 

Fig. 1 
 
Heater dimensions 

        The “above-supply-point” version  

           The “below-supply-point” version   

 

 

 

 

 
 
 

A

B

C

D

E

TO 5 UP

400

280

-

260

265

TO 5 IN

400

-

155

260

265

TO 10 UP

500

398

-

350

265

TO 10 IN

500

-

122

350

265

TO 15 UP

500

398

-

350

310

TO 15 IN

500

-

122

350

310

Содержание TO 10 IN

Страница 1: ...ELECTRIC WATER HEATER TO 5 IN UP TO 10 IN UP TO 15 IN UP Dru stevn z vody Dra ice stroj rna s r o Works Cooperative Dra ice Machine Plant Ltd Dra ice 69 29471 Ben tky nad Jizerou Tel 326 370 911 fax...

Страница 2: ...es the right for engineering modification of the product The product is designed for permanent contact with drinkable water Guide Contents 1 PRODUCT ACCESSORIES 3 2 MESSAGE FOR CUSTOMERS 3 3 TECHNICAL...

Страница 3: ...ween 5 C and 75 C using the symbols on the thermostat selector button read more in chapter 13 Cold water inflow is indicated with a blue ring hot water outflow is indicated with a red ring 4 GENERAL T...

Страница 4: ...t water Safety valve is mounted on the cold water inlet identified with a blue ring Each hot service water pressure heater must have a safety valve with a membrane spring Nominal clearance of safety v...

Страница 5: ...er and water main installation b open the hot water valve on the combination faucet c open the cold water inlet valve to the heater d As soon as the water starts running through the hot water valve th...

Страница 6: ...t is on until the water in the heater heats up to the selected temperature or until switched off as scheduled Due to heating the volume of water increases which causes water dripping from the combinat...

Страница 7: ...gainst electric shock SN 33 2000 5 51 Electric installations of buildings SN 33 2000 7 701 Low voltage electric installations Single purpose devices and devices in special premises Premises with tub o...

Страница 8: ...8 Fig 2 Wiring scheme Explanation 1 Thermostat 2 Thermal fuse non reversible 3 Heating element 4 Operation indicator 5 Terminal board L Phase conductor N Null conductor Earth conductor 04 2012...

Отзывы: