background image

-

 

 

Type

1

2

3

4

5

Ex changer 1m 2

7

24

51

86

130

Ex changer 1.45m 2

9

32

68

115

174

Pressure l oss m bar

tHV = 60 °C

Am ount of heati ng w ater m 3/h

1

1,5

2

3

5

10

20

50

100

200

Výměník s teplosměnou
plochou 1 m2 

Výměník s teplosměnou 
plochou 1,45 m2 

Průtok topné vody  m3/h

O

d

p

o

to

p

n

é

 v

o

d

y

m

b

a

r

4

 

Tanks must be provided with discharge valve 

mounted on the cold sanitary water inlet to the tank 
for potential disassembly or repair.

  

When  assembling  the  security  equipment,  follow 
the standard.

 

SAFETY VALVE 

START-UP 

PRESSURE 

[MPa]

 

ALLOWABLE 

OPERATING 

OVERPRESSUR

E OF WATER 

HEATER [MPa]

 

MAXIMUM 

PRESSURE IN 

COLD WATER 

PIPES [MPa]

 

0,6

 

0,6

 

up to 0.48 

0,7

 

0,7

 

up to 0.56 

1

 

1

 

up to 0.8 

Table 2 

  

2.4

 

PRESSURE LOSSES 

 

 

 

 

 

 

 

 

 

 

2.5

 

CONNECTION OF INDIRECT TANK TO HOT WATER SYSTEM 

a)

 

Water heating by electric energy

 

When the tank

 

is connected to power supply, the heating element heats water.

 

The element is turned on 

and off by a thermostat.

 

After reaching the temperature set, the thermostat switches off the electric circuit 

and thus discontinues water heating.

 

The control light signals if the element is in operation (light is on) or if 

it is off (the light goes out).

 

In case of longer operation without using the heated volume, the thermostat 

has to be set to position 5°C to 8°C (set the “snowflake” symbol on the thermostat selector) to avoid its 
freezing, or electricity supply to the heater has to be switched off.

 

In combined tanks, the stop valve on the 

inlet to the exchanger has to be closed at the inlet to the heat exchanger which prevents heating the water 
in the hot water heating system.

 

 

Exchanger 

with 

heat 

transfer surface 1.45 m

2

 

 

Exchanger 

with 

heat 

transfer surface 1 m

2

 

Heating water flow m

3

/ho

ur 

He

at

in

w

at

er 

re

sist

an

ce

 

m

ba

r

 

Содержание Okce 100

Страница 1: ...MANUAL STATIONARY ELECTRICAL HOT WATER TANKS OKCE 100 NTR 2 2 kW OKCE 125 NTR 2 2 kW Dru stevn z vody Dra ice stroj rna s r o Dra ice 69 294 71 Ben tky nad Jizerou Phone 420 326 370 990 Fax 420 326 37...

Страница 2: ...kW 7 2 3 PLUMBING FIXTURE 8 2 4 PRESSURE LOSSES 9 2 5 CONNECTION OF INDIRECT TANK TO HOT WATER SYSTEM 9 2 6 EXAMPLES OF tankS CONNECTION 10 2 7 FIRST COMMISSIONING 12 2 8 CLEANING OF TANK AND EXCHANG...

Страница 3: ...would like to thank you for your decision to use a product of our brand With this guide we will introduce you to the use construction maintenance and other information on electrical water heaters The...

Страница 4: ...tube and as a unit it is entirely coated with hot water resistant enamel A flange is welded onto the upper bottom of the receptacle with a flange lid screwed to it A sealing ring is inserted between t...

Страница 5: ...524 E 195 195 F 635 765 L 535 635 Typ OKCE 100 NTR 2 2 kW OKCE 125 NTR 2 2 kW 1 3 DESIGN AND BASIC DIMENSIONS OF TANK OKCE 100 NTR 2 2 kW OKCE 125 NTR 2 2 kW Figure 1 1 outer 3 4 inner 3 4 outer 1 2...

Страница 6: ...RE OF HOT WATER C 80 Heating surface of bottom heat exchanger m2 1 1 45 BOTTOM HEAT EXCHANGER POWER AT HEATING WATER TEMPERATURE OF 80 AND FLOW OF 720 l h kW 24 32 PERMANENT HOT WATER POWER l h 610 99...

Страница 7: ...f the common decalcifying devices was installed with the appliance or that the thermostat was set to the minimum operating temperature of 60o C setting to position ECO For proper operation drinkable w...

Страница 8: ...ed between the tank and the safety valve During assembly follow the guide provided by the safety equipment manufacturer It is necessary to check the safety valve each time before putting it into opera...

Страница 9: ...heating by electric energy When the tank is connected to power supply the heating element heats water The element is turned on and off by a thermostat After reaching the temperature set the thermosta...

Страница 10: ...n the floor next to the heating source or in its proximity The heating circuit shall be connected to marked tank exchanger inputs and outputs and bleeder valve installed at the highest point It is nec...

Страница 11: ...ample of group connection of tanks by Tichellman method for equal HSW withdrawal of from all tanks OV Heating water TUV Hot service water SV Cold water 1 Return valve C Circulation 2 Pump Figure 3 Fig...

Страница 12: ...heating system turn off electricity an open the valves on the heating water inlet and outlet possibly de aerate the exchanger i once the operation restarts keep flushing the tank until the cloud disap...

Страница 13: ...for the thermostat control lights with wires temperature indicator set of M12 or M10 bolts heating element When ordering spare parts give part name type and type number from the heater label 3 OPERAT...

Страница 14: ...er is cold Light off Thermostat failure The safety thermostat shut off the power supply Electric supply outside the heater interrupted Temperature of water is not corresponding with the temperature se...

Страница 15: ...s of the flange joint of the tank It is not allowed to handle the thermostat aside from temperature resetting with a control button All electric installation handling setting and regulation feature ex...

Страница 16: ...livered The service fee was paid pursuant to Act No 477 2001 Coll as amended at EKO KOM a s The client number of the company is F06020274 Take the water boiler packages to a waste disposal place deter...