N

L

1

2

3

4

COM    OFF     ON

MAINS

FUSED 3A

LINK FOR

230V OUTPUT

W

A

LL

P

LA

T

E

C

LO

C

K

A

B

C

D

Installation instructions

MAKE SURE MAINS INPUT HAS
A

3 AMP

FUSE FITTED.

Installation should be carried
out by a qualified electrician or
heating engineer.

Position the wallplate with 

70 mm clearance to its right, 
25 mm above and 150mm below.
Ensure that the supporting
surface will fully cover the back
of the timeswitch.

Fix the wallplate, terminals at

the top, either direct to a flat
wall using wall plugs and 1" x
No.6 woodscrews or on a flush
mounting single conduit box
type UA1 (BS4662) using M3.5 x
14 mm screws. DO NOT use a
surface mounting box.

Make wiring connections as

shown in the wiring diagram.

Tempus 1 electronic timeswitch

User instructions

Tempus 1 has volt-free switching
so a link from L to 1 is required
for 230V output. For surface
wiring, snap out the cable entry
strip on the bottom edge of the
wallplate. Tempus 1 is double
insulated and needs no earth con-
nection but an earth continuity
terminal is provided if required.

Select 5/2 day or 24HR mode

referring to the jumper position
diagram. 

There are two positions marked

C/D. The jumpers should be
removed if necessary and placed
across the pins which correspond
to the desired option. A/B are
not used. 

Fit the Tempus 1 onto the

wallplate and tighten the
securing screws. Check that the
fuse is rated correctly (3A) and
switch on the mains supply.

Never fit the
programmer to a live
wallplate

Jumper position

A = Not used
B = Not used
C = 5/2 day mode
D = 24 hour mode
Place the jumper 
across the two pins

Wiring connections

Conforms to the essential requirements 
of the following directives:

89/336/EEC – Electromagnetic compatibility
73/23/EEC

– Low voltage directive

Drayton

Advance

Boost

Select

Day

Time

Slider

switch

The Tempus 1 electronic time-
switch will automatically switch
ON and OFF up to three times a
day. You can select one set of
times for weekdays and different
times for weekends (5/2 day), or
programme each day of the
week the same (24 hour).  

The BOOST feature gives an

extra one or two hours ON time
when selected. The display will
show the next switching time as
well as the actual time of day. In
the event of a power failure, the
battery back-up will hold the
programme times in memory.

All changes to clock and

programme times are made
using the slider switch, together
with the TIME and DAY buttons.
Follow the step-by-step
instructions overleaf to set your
desired programme.

Important note: 
If you are replacing an old
style Tempus, move the wire
connected to terminal 2 on the
wall-plate to terminal 3 (ON).

Please read the following
notes before programming
your Tempus

You cannot set the first ON

before midnight (i.e. the
previous day).

If you try to set an ON time

after

it's matching OFF time,

both will ‘lock’ and the ON and
OFF symbols in the display will
flash alternately.

Press SELECT and TIME 

+

at

the same time to return all
settings to factory pre-sets.

The slider switch must be in

the RUN position before the
cover will close.

To select 5/2 day or 24 hour
modes see installation
instructions on back page.

Customer Service Tel: 0845 130 5522
Customer Service Facsimile: 0845 130 0622
Technical Helpline Tel: 0845 130 7722
Website: www.draytoncontrols.co.uk
Email: [email protected]

Invensys continuously seek to improve products and reserve the right to make
changes without notice

090-807 Issue C

Technical data

Voltage

230V AC +15% -10% 50 Hz

Rating

2 (1) A 230V AC

Wiring

Designed for Fixed Wiring only
to comply with current I.E.E. regulations

Battery Backup

Display:

Typically 1 hour

Timekeeping: 7 to 8 hours
Programme:

Minimum 1

1

2

years

Programme 
Resolution

10 minutes

Ambient 

Operating:

0°C to 50°C     

Temperature

Storage:

-20°C to 50°C

Maintenance

No user maintenance should be attempted.

Factory pre-set
programme

24 hour   

Sat & Sun

or Mon-Fri

1st ON 6.30am

7.00am

1st OFF 8.30am

9.00am

2nd ON 12.00 noon 12.00 noon
2nd OFF 12.00 noon 12.00 noon
3rd ON 4.30pm

4.00pm

3rd OFF 10.30pm

11.00pm

Invensys Controls Europe

Tempus 1 user inst 090-807 IssC  5/5/06  00:15  Page 1

Отзывы: