MiStat

 

INSTALLATION

 Guide

Applications

The electronic room thermostat MiStat P can be used 
for temperature control together with:

•  Boilers
•  Oil and gas warm water heating
•  Actuators of fl oor heating systems or radiators
•  Circulating pumps
•  Heat pumps

   A MiStat R receiver is required for operation.

Note:

 To ensure a properly working heating 

system, the menu items in the Installer settings 
have to be set according to the needs of the 
heating system, see step 5.

Caution! 

The radio receiver may be installed only by a competent
electrician in compliance with the circuit diagram 
enclosed in the top housing cover or in compliance 
with these instructions. The current safety regulations 
must be observed.

In order to achieve protection class II, adequate 
installation measures must be taken.

This radio receiver, which can be installed separately, 
is designed exclusively for temperature control in dry 
and closed rooms and standard environments. This 
electronic device was created according EN60730-1, it 
operates according working principle 1C.

Step 1:

 Mounting the Wall-plate

IMPORTANT:

Installation must only be carried out by a 
qualifi ed electrician or heating engineer.

Make sure mains input has a 3 amp fuse.

CAUTION! Before installation, make sure the 

mains supply is switched off!

Option 2: Using an existing wall-plate

Loosen the securing screws on the old receiver 
and unplug it.  Check that there’s 20mm 
clearance to the right of the wall-plate and 25mm 
above it.  Check the wiring diagram for your 
product model to compare terminals and, if 
necessary, change the wiring of the wall-plate to 
suit.  Now plug the MiStat R unit into the 
wall-plate and tighten the securing screws.

Check the 3A fuse, and switch on the mains.

Option 1: Fitting a new wall-plate

The ideal location is close to the boiler or central 
heating system.  For the best performance install 
in an open space, at least 30cm distance from any 
metal objects including wall boxes and the boiler 
housing.  It is recommended that the MiStat R is 
mounted on the wall nearest the fi nal location of 
the MiStat P room unit and not less than 30cm 
from the boiler side panel. 

Loosen the securing screws, remove the wallplate 
and, if surface wiring is to be used, snap out 
the cable entry strip on the bottom edge of the 
wallplate with a pair of pliers.  Fix the wallplate, 
terminals at the top, either direct onto the fl at 
wall using wall plugs and no 6 x1” wood screws 
or on a plastic fl ush mounting single conduit box 
using M3.5 x 14 screws. Check that there’s 20mm 
clearance to the right of the wall-plate and 25mm 
above it.  Complete the wiring to the MiStat R 
wallplate in accordance with the wiring diagram 
in step 2, to comply with current IEE regulations.  
Place the MiStat R onto the wallplate and tighten 
the securing screws. 

Check the 3A fuse, and switch on the mains.

Warning:

 Installing the MiStat R too close to the 

metal side panel or mains cables may interfere 
with the radio signal.

DO NOT 

use a surface 
mounting box

Step 2:

 Wiring

This product is double insulated and does not 
require an earth connection. The MiStat R should 
be wired to the boiler or central heating wiring 
using the correct type of cable or fl ex. The MiStat 
R should be wired to replace hard wired room 
or programmable thermostats, as shown on the 
system or boiler wiring diagrams. 

Always check other manufacturers instructions for 
compatibility.

N

L

     2

3

230V AC 50Hz
Fused 3A

Common

heating 

satisfied 

or call for 

cooling

Call for 

heat

Volt free contacts

Combi boiler basic wiring layout

Zone control basic wiring layout

N     L     1     2      3

L

MiStat R

MiStat R

Switched live 

from wiring 

centre

Motorised valve 

To boiler 

and/or 

pump 

Radio signals 

to MiStat R - no wiring

230V AC 

fused 3A

N     L     1     2      3

          

 L  - 
 N - 

Radio signals 

to MiStat R - no wiring

Switched  

230V AC 

fused 3A, 

Internal 

boiler 

electronics 

External 

controls 

connections 

N     L     1     2      3

          

L

 

MiStat R

MiStat R

Switched live 

from wiring 

centre

Motorised valve 

To boiler 

and/or 

pump 

Radio signals 

to MiStat R - no wiring

  

230V AC 

fused 3A 

N     L     1     2      3

 L  - 
 N - 

Radio signals 

to MiStat R - no wiring

Switched 

230V AC 

fused 3A, 

Internal

boiler

electronics 

External 

controls 

connections

Step 3:

 Signal Strength

The MiStat Programmable Room thermostat is pre-
bound to the MiStat receiver in the factory so they just 
need to be positioned in the best place for wireless 
communication. 

To help with this there is a built in Signal strength 
indicator as shown below (see also Step 5 Installer 
settings).

It is recommended that the signal strength is ‘Good’
or ‘Very Good’ to ensure ongoing communication 
is maintained.

If ‘Poor’ is displayed, look for a better location.
If ‘No Signal’ is displayed, try connecting again with 
the room unit in a different position.

Note:

 If not bound, the bind screen will be visible.

For commissioning see Step 6