VigorSwitch P2280 User’s Guide
197
Parameter
value/LAN
10Base 100Base
1000Base
Max. collision
domain DTE to
DTE
100 meters
100 meters for
UTP
412 meters for
fiber
100 meters for
UTP
316 meters for
fiber
Max. collision
domain with
repeater
2500 meters
205 meters
200 meters
Slot time
512 bit times
512 bit times
512 bit times
Interframe Gap
9.6us 0.96us
0.096us
AttemptLimit
16 16 16
BackoffLimit
10 10 10
JamSize
32 bits
32 bits
32 bits
MaxFrameSize
1518 1518 1518
MinFrameSize
64 64 64
BurstLimit
Not applicable
Not applicable
65536 bits
In full-duplex operation mode, both transmitting and receiving frames are processed
simultaneously. This doubles the total bandwidth. Full duplex is much easier than half duplex
because it does not involve media contention, collision, retransmission schedule, padding bits
for short frame. The rest functions follow the specification of IEEE802.3. For example, it must
meet the requirement of minimum inter-frame gap between successive frames and frame
format the same as that in the half-duplex operation.
Because no collision will happen in full-duplex operation, for sure, there is no mechanism to
tell all the involved devices. What will it be if receiving device is busy and a frame is coming
at the same time? Can it use “backpressure” to tell the source device? A function flow control
is introduced in the full-duplex operation.
Содержание VigorSwitch P2280
Страница 1: ......
Страница 9: ...VigorSwitch P2280 User s Guide 1 P Pa ar rt t I I I In nt tr ro od du uc ct ti io on n ...
Страница 26: ...VigorSwitch P2280 User s Guide 18 This page is left blank ...
Страница 27: ...VigorSwitch P2280 User s Guide 19 P Pa ar rt t I II I S Sw wi it tc ch h L LA AN N ...
Страница 68: ...VigorSwitch P2280 User s Guide 60 ...
Страница 82: ...VigorSwitch P2280 User s Guide 74 ...
Страница 97: ...VigorSwitch P2280 User s Guide 89 P Pa ar rt t I II II I S Se ec cu ur ri it ty y ...
Страница 105: ...VigorSwitch P2280 User s Guide 97 click it to remove the selected entry ...
Страница 113: ...VigorSwitch P2280 User s Guide 105 ...
Страница 132: ...VigorSwitch P2280 User s Guide 124 This page is left blank ...
Страница 133: ...VigorSwitch P2280 User s Guide 125 P Pa ar rt t I IV V A AC CL L C Co on nf fi ig gu ur ra at ti io on n ...
Страница 143: ...VigorSwitch P2280 User s Guide 135 P Pa ar rt t V V Q Qo oS S C Co on nf fi ig gu ur ra at ti io on n ...
Страница 154: ...VigorSwitch P2280 User s Guide 146 This page is left blank ...
Страница 155: ...VigorSwitch P2280 User s Guide 147 P Pa ar rt t V VI I P Po oE E C Co on nf fi ig gu ur ra at ti io on n ...
Страница 161: ...VigorSwitch P2280 User s Guide 153 P Pa ar rt t V VI II I S Sy ys st te em m M Ma ai in nt te en na an nc ce e ...
Страница 174: ...VigorSwitch P2280 User s Guide 166 ...
Страница 187: ...VigorSwitch P2280 User s Guide 179 ...
Страница 190: ...VigorSwitch P2280 User s Guide 182 This page is left blank ...
Страница 191: ...VigorSwitch P2280 User s Guide 183 P Pa ar rt t V VI II II I D Di ia ag gn no os st ti ic cs s ...
Страница 198: ...VigorSwitch P2280 User s Guide 190 This page is left blank ...