background image

 

 

iii 

 

 

 

Declaration of Conformity 

We DrayTek Corp. , office at No.26, Fushing Rd., Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan, declare under our sole 
responsibility that the product 

 

Product name: 

VDSL2 Security Router 

 

Model number:   

Vigor2765/Vigor2766 Series 

 

Manufacturer:   

DrayTek Corp. 

 

Address:   

 

No.26, Fushing Rd., Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan                                     

 

Importer: 

 

SEG, 11 Capital Business Park, Borehamwood, Herts, WD6 1GW 

is in conformity with the relevant UK Statutory Instruments: 

The Electromagnetic Compatibility Regulations 2016 (SI 2016 No.1091), The Electrical Equipment (Safety) Regulations 2016 (SI 
2016 No.1101), The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019 (SI 
2019 No.539) and The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 
2012 (SI 2012 No. 3032) with reference to the following standards: 
 

Standard 

Version / Issue date 

EN 55032 

2015+A1:2016 class B 

EN 61000-3-2 

2014 

EN 61000-3-3 

2013 

EN 55024 

2010+A1:2015 

EN 62368-1 

2014/A11:2017 

EN IEC 63000:2018 

2018 

SI 2019 No.539 

2019 

 
 
 
 

Hsinchu                                       

 

 

     2nd September, 2019                                              Calvin Ma / President   

(place)                                                             

 

    (date) 

 

                                                (Legal Signature) 

 

 

 

EU Declaration of Conformity 

We DrayTek Corp. , office at No.26, 

Fushing Rd., Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan, declare under our sole 

responsibility that the product 

     

 

Product name:       

VDSL2 Security Router

 

 

Model number:   

Vigor2765

/Vigor2766 Series

 

 

Manufacturer:   

DrayTek Corp. 

 

Address:   

 

No.26, Fushing Rd., Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan   

 

Importer: 

 

SEG, 11 Capital Business Park, Borehamwood, Herts, WD6 1GW 

 

is in conformity with the relevant Union harmonisation legislation:   
EMC Directive 2014/30/EU , Low Voltage Directive 2014/35/EU , ErP 2009/125/EC and RoHS 
2011/65/EU with reference to the following standards 

Standard 

Version / Issue date 

EN 55032 

2012+AC:2013 class B 

EN 61000-3-2 

2014 Class A 

EN 61000-3-3 

2013 

EN 55024 

2010+A1:2015 

EN 62368-1 

2014/A11:2017 

EN IEC 63000:2018 

2018 

EC No. 1275/2008 

2008 

 

 

Hsinchu

                                               

 

 

  1st Oct., 2019   

                   

 

           

Calvin Ma / President

   

(place)                            

 

 

    (date)   

                          (Legal Signature)

 

Содержание 2ABB012F EU

Страница 1: ...ity For all models please check that you have been supplied with a device intended for your geographic region and networks Hardware and software varies by region as well as local support and warranty...

Страница 2: ...nual and online documentation and to make changes from time to time in the contents hereof without obligation to notify any person of such revision or changes External Power Supply Power Adapter Infor...

Страница 3: ...ssue date EN 55032 2015 A1 2016 class B EN 61000 3 2 2014 EN 61000 3 3 2013 EN 55024 2010 A1 2015 EN 62368 1 2014 A11 2017 EN IEC 63000 2018 2018 SI 2019 No 539 2019 Hsinchu 2nd September 2019 Calvin...

Страница 4: ...ion Setup 8 4 2 1 PPPoE connection with FTTC VDSL2 8 4 2 2 DHCP Static IP connection with FTTC VDSL2 11 4 2 3 PPPoA connection with ADSL ADSL2 14 4 3 WAN2 Ethernet Connection Setup 16 4 3 1 Enabling t...

Страница 5: ...ck Start Guide This document RJ 45 Cable Ethernet Connects to your PC or Switch RJ 11 to RJ 11 Cable Connects to your DSL line UK Power Adapter The maximum power consumption is 15 Watts Important Note...

Страница 6: ...d On USB device is connected and ready for use USB Blinking Data is being transmitted over USB Interface Description Factory Reset Restore the default settings Usage Turn on the router ACT LED is blin...

Страница 7: ...e router to your computer or switch 3 Power Supply Connect the power adapter to the Vigor 2765 s PWR socket on the rear and plug the power adapter into a suitable mains socket Turn the Vigor 2765 on u...

Страница 8: ...ing slots on the underside to hang the router on using screws attached to a wall or other surface 1 Drill two holes on the wall The distance between the holes shall be 168mm 2 Fit screws into the wall...

Страница 9: ...nge For details on how to change this please refer to the Trouble Shooting section in the User Guide 4 4 1 1 A Ac cc ce es ss si in ng g t th he e R Ro ou ut te er r W We eb b I In nt te er rf fa ac c...

Страница 10: ...ter s default certificate is self signed rather than issued to you by a certificate authority who has verified your identity A self signed certificate means that you cannot verify the identity of the...

Страница 11: ...ccessful login the router will display the Dashboard which shows a summary of the router model WAN status front panel port status and other information Note We recommend configuring a secure password...

Страница 12: ...your ISP has supplied you with a Username and Password to connect to the Internet go to section 4 2 3 PPPoA connection with ADSL ADSL2 4 4 2 2 1 1 P PP PP Po oE E c co on nn ne ec ct ti io on n w wi...

Страница 13: ...ettings tab Select the Enable radio button at the top of the page to ensure that the PPPoE interface is enabled In the ISP Access Setup section input the ISP username into the Username field and passw...

Страница 14: ...t to restart Click the OK button to restart the router 5 Once the router has restarted the Online Status Physical Connection page will display the VDSL information and PPP connection status if the WAN...

Страница 15: ...DS SL L2 2 1 Go to WAN General Setup and click on the WAN1 link 2 On the settings page Set the Enable option to Yes to activate the WAN1 connection Set the Active Mode to Always On Enable the Service...

Страница 16: ...ck the Details Page button to proceed 4 In the MPoA Static or Dynamic IP settings Select the Enable option and select Obtain an IP address automatically which will obtain an IP from the ISP using DHCP...

Страница 17: ...t to restart Click the OK button to restart the router 5 Once the router has restarted the Online Status Physical Connection page will display the VDSL information and DHCP connection status if the WA...

Страница 18: ...sage with 0 and 38 being the defaults In most cases it will not be necessary to change these The Modulation setting can be left on its default of Multimode which will auto detect the correct ADSL type...

Страница 19: ...ill display the ADSL information and PPP connection status if the WAN1 section shows an IP address it has connected to the internet successfully Note If the WAN 1 IP address displayed begins with 172...

Страница 20: ...ed to a modem and the ISP does not supply or require a Username and Password to connect to the Internet or you are connecting to another router or network see section 4 3 3 Static or Dynamic IP 4 4 3...

Страница 21: ...change and the router will prompt to restart Click OK to restart the router Once the router has restarted the WAN2 Ethernet WAN interface can be configured on the router as shown in the following two...

Страница 22: ...name field and password in the Password field as required The Service Name does not need to be specified If your ISP has provided a static IP address that can be specified by setting the Fixed IP sett...

Страница 23: ...the ISP with DHCP If your ISP has provided a static IP range with a Network address and a Subnet Mask specify that with the Specify an IP address option Click OK on this page to apply the changes and...

Страница 24: ...used where the modem operates as a virtual network adapter router and will usually have diagnostics and usage information shown in a web interface When configuring the 3G 4G modem the router will req...

Страница 25: ...nitial String to indicate that it has been saved Click OK to save and apply the changes If the modem is detected successfully the WAN interface should be able to connect Status information can be view...

Страница 26: ...ill use whichever mode the base station recommends Setting this to a specific mode will force that connection type for instance 4G Only will connect using 4G specifically The APN Name will typically n...

Страница 27: ...nhanced services see www draytek co uk vigorcare You should keep your proof of purchase original invoice safely in case warranty or other service is ever required 5 5 1 1 A Ad dd di it ti io on na al...

Страница 28: ...ur ri it ty y R Ro ou ut te er r B Be es st t P Pr ra ac ct ti ic ce e Your router is the gateway to an entire business network and data Even the best security equipment requires correct usage in orde...

Отзывы: