Drawmer THREE-SUM Скачать руководство пользователя страница 6

6

DRAWMER

 T

HREE

-

SUM

 O

PERATOR’S 

M

ANUAL

CONTROL DESCRIPTION

Input Level Trim:

-10dB - +10dB

Typically, the Input Trim level control is used to match the output of the preceding
device to the input needs of the three compressors that the signal will pass
through. Alter the “Meter Input/Output Switch” to "input" to see the effect of the
input trim on the signal level to the three compressors.
On an optimal signal the 0dB provides optimum headroom and signal-to-noise
ratio. If the input trim is set too low little compression will occur (and, raising the
overall output level of the signal will amplify the noise floor). Alternatively, increasing
the input trim control pushes more level into the compressors and therefore more
compression occurs.

Low Split Frequency:

18Hz - 1.6kHz

Sets the frequency point at which the split between low and mid bands occurs.

High Split Frequency:

530Hz - 42kHz

Sets the frequency point at which the split between mid and high bands occurs.

THREE BAND

Switches:
Low: is the signal below that set by the Low Split Frequency;
Mid: is the signal between that set by the two Split Frequency controls;
High:  is the signal above that set by the High Split Frequency control.

Across all three bands

Mute:

In the “MUTE” position the signal for that particular band is effectively turned off.
Any combination of mute is available - to hear only the signal of the low band
mute the mid and high bands etc.

Bypass:

In the “BYPASS” position the signal for the low, mid, or high band is allowed to
pass through to the summing stage without being output to a compressor.

Using a combination of mute and bypass switches for the various bands allows
the operator to hear and monitor only the frequencies that are required and so
tune the low and high frequency settings.

Output Gain:

-10dB - +10dB

After the three bands have returned to the Three-Sum the signal is summed back
to a single stereo band. If at this point the signal is too low or so high that
eccessive limiting occurs then it would be difficult to adjusts all three gain controls
of each compressor whilst maintaining the low/mid/high balance, for this reason
a single OUTPUT GAIN control has been incorporated.
Adjust so that the limiter works only on signal peaks.

CHAPTER 2

Содержание THREE-SUM

Страница 1: ...ion Chapter 1 Introduction Introduction Installation Audio Connections Power Connection Chapter 2 Control Description Control Description Chapter 3 Operation Operation Chapter 4 General Information If...

Страница 2: ...THIS WARRANTY SHALL BE REPAIR OR REPLACEMENTAS SPECIFIED HEREIN IN NO EVENT WILL DRAWMER ELECTRONICS LTD BE LIABLE FORANYDIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY...

Страница 3: ...threshold brick wall limiter section with bypass facility To ensure transparency the limiter design is two stage applying different processing to the H F content of the material In applications where...

Страница 4: ...e operating level is nominally 4dBu Balanced use is recommended Interference If the unit is to be used where it maybe exposed to high levels of disturbance such as found close to a TV or radio transmi...

Страница 5: ...used with a mains input operating voltage different to that for which the unit is supplied the following procedure must be carried out by a technically competent person see following diagrams fig 2 T...

Страница 6: ...by the Low Split Frequency Mid is the signal between that set by the two Split Frequency controls High is the signal above that set by the High Split Frequency control Across all three bands Mute In t...

Страница 7: ...eliberately driven into limiting to produce creative effects G R Meter 1 3 6 10dB VU Meter A moving coil VU meter monitors either the level of the output or input signal Because the meter has VU chara...

Страница 8: ...band compressor using more compression in the mid band can often help lift out the vocals Likewise compress the top end a little harder to give it more brightness or enhancement If the gain reduction...

Страница 9: ...e Sum has primarily been designed for use as a three band compressor however the fact that it uses external compressors after splitting the signal into its three bands opens up endless other uses The...

Страница 10: ...rial capable of withstanding the handling for the transit CONTACTING DRAWMER Drawmer Electronics Ltd will be pleased to answer all application questions to enhance your usage of this equipment Please...

Страница 11: ...11 DRAWMER THREE SUM OPERATOR S MANUAL BLOCK DIAGRAM Three Sum ver 01 B 15 06 06...