DRAWMER

CONTROL DESCRIPTION

The DS101 noise gate incorporates many
impressive features, many pioneered by
Drawmer, which are invaluable to the sound
engineer and not found on conventional noise
gates:

 Variable high-pass and low-pass filters for

‘frequency conscious’ gating, with ‘Key listen’
facility.
 

 Comprehensive envelope control, attack, hold,

decay and range.
 

 Ultra-fast response time.

 

 ‘Traffic light’ display giving clear indication of

gate status as well as Threshold Metering.
 

 Key input for external triggering.

 

 Linking. Each DS101 can be linked to another

whilst still retaining independent envelopes.
 

 Can be used for "Gating" or "Ducking".

 

 High audio specification.

These features are based on the industry
standard, DS201 Noise Gate manufactured by
Drawmer since 1981.

The Gate Controls

Threshold

Infinite to -62.0dB

Sets the level below which gating starts to take
place. For normal noise removal applications,
it is usual to set the Threshold as low as is
possible without spurious triggering occurring,
so that none of the desired signal is lost. The
meter above clearly shows the threshold level
in response to the actual signal.

Attack

10uS to 1S

Controls the speed that the gate opens. The
fastest Attack time ensures that the gate does
not clip the leading edge of extremely fast
signals.

Hold

2mS to 2 Seconds

Determines the amount of time the gate is held
open after the signal falls below the Threshold.
This helps to prevent spurious re-triggering
when using fast Release times, but is also
instrumental in creating the classic gated reverb
sound which is often applied to drums.

CHAPTER 2

Содержание DS101

Страница 1: ...tion Typical Connection Guide Chapter 2 Control Description The Gate Controls The Key Filters Quick Start Guide Noise Gate Operation Chapter 3 General Information If a fault develops Contacting Drawme...

Страница 2: ...GES Some states and specific countries do not allow the exclusion of impliedwarrantiesorlimitationsonhowlonganimpliedwarrantymay last sotheabovelimitationsmaynotapplytoyou Thiswarrantygives youspecifi...

Страница 3: ...r more gates can be linked using the new infra red triggering mechanism employed on the DS101 This means that any number of gates can be linked with each having their own envelope shaping whilst the t...

Страница 4: ...connectors provided by an API 500 series compatible rack frame not included Installing the DS101 into a 500 Series compatible rack 1 Before you install anything be sure to turn off the 500 series rac...

Страница 5: ...5 DS101 Noise Gate for 500 Series Systems TYPICAL CONNECTION GUIDE...

Страница 6: ...ustry standard DS201 Noise Gate manufactured by Drawmer since 1981 The Gate Controls Threshold Infinite to 62 0dB Sets the level below which gating starts to take place For normal noise removal applic...

Страница 7: ...will be reduced when open triggered Traffic Light Meter A three led meter is used to show the operation of the gate When red the gate is closed when green the gate is open and when yellow the gate is...

Страница 8: ...Bypass switches remain indepentent In this way the triggers are the same but differing envelopes can be used for each channel Using External Keys An external audio source may be used to control the G...

Страница 9: ...the following suggestions 1 Select the Key trigger source using the Key section 2 Initially the LF filter should be set fully anticlockwise with HF fully clockwise This will allow the full audio spect...

Страница 10: ...from its zero level point as this wave climbs towards its peak the level will suddenly exceed the threshold setting at this point a very fast attack rate will switch the signal through the noise gate...

Страница 11: ...al where the peaks are too loud and require attenuating In this application Duck and Internal i e source switch not selected modes should be selected and the Range control adjusted to give the desired...

Страница 12: ...e acoustic guitar even a bright sounding steel strung model and the filters can be used to reduce the effect of string squeak or the player s breathing When recording drum kits most engineers encounte...

Страница 13: ...ely that the Threshold will have to be re adjusted as the level may have to be quite high and you will have to be careful not to miss the quieter hits but the hi hat should be gated completely with no...

Страница 14: ...ey input is making particular parts start and finish at the same time Regarding vocals and brass sections performers may start a fraction early some end a fraction late Link the channels and use the b...

Страница 15: ...mber will be issued Write this RA number in large letters in a prominent position on the shipping box Enclose your name address telephone number copy of the original sales invoice and a detailed descr...

Страница 16: ...16 DRAWMER Ref 1v01 B 24 01 13 BLOCK DIAGRAM...

Страница 17: ...17 DS101 Noise Gate for 500 Series Systems...

Отзывы: