background image

3

8.8.8.8.8.8.

Battery Voltage U=
Maximum capacity
------------

Finally the balance stays in a standby state of showing 0g, 0.0g in the display

Notice

: the lasting time of --------- will be decided by the stability of the loadcell, thus, the

balance must not be located in an unstable surface or in the wind blow. If O flashes in the
display, it means the balance is not in a stable condition, calibration and counting operations
is not allowed.

CALIBRATION

The purpose for this operation is to calibrate the balance so as to achieve the best
performance in case there is obvious tolerance error in weighing or the balance is
located in different gravity due to different latitude.

It is suggested to warm up the balance over half an hour before calibration.

Remove all loads from the platter, press function key

TARE

to clear the readings to

0g ,0.0g.
Press and hold function key

CAL

for 3 seconds, release function key

CAL

when

“---CAL---“ is shown in the display, a figure of standard weight will flash in the display,
put a standard weight on the platter accordingly, standby state “------“ will be shown in
the display for a few seconds before the standard weight figure is shown in the
display, remove the weight, “------“ standby state will remain for a few seconds before
the balance enter stable weighing mode, showing 0g ,0.0g.
It is recommended to make the operations twice to

achieve the best calibration

result.

WEIGHING

When the balance is warmed up and calibrated, 0g,0.0g is shown in the display

indicating weighing mode, put the object on the platter, when stable, the weight of the object
is shown in the display.

TARING

When a loader is put over the platter, its weight is shown in the display, press function key

TARE

, 0g, 0.0g will be shown in the display, indicating the weight of the loader is deducted,

put the object into the loader, when stable, the figure shown in the display is the weight of
the object.

PIECE COUNTING

Remove all loads from the platter, press function key

TARE

to clear the readings in the

display, press function key

COU

to enter counting mode, figure

10(default

sampling

quantity)

will

be

shown

in

the

display,

weighing

unit

Содержание YP Series

Страница 1: ...YP Series Industrial Precision Balance INSTRUCTION MANUAL Thank you for choosing our electronic balance...

Страница 2: ...nearity g 0 2g 0 2g 0 2g Corner Error g 0 2g 0 2g 0 2g Pan Size mm 337 237mm Dimensions LxWxH 370 370 125mm Power supply AC110V 220V Rechargeable battery 4V 4AH Model No YP15K YP10000D YP20000D YP3000...

Страница 3: ...for counting TARE to tare UNIT for unit conversion g lb kg CAL for calibration MENU for priting ASSEMBLING Unpack the package put the platter on the top of the loader Put the balance on a steady flat...

Страница 4: ...weight will flash in the display put a standard weight on the platter accordingly standby state will be shown in the display for a few seconds before the standard weight figure is shown in the display...

Страница 5: ...tive immediately from the platter so as to prevent damages to the balance INTERFACE RS232 Connection Balance 9 pins Printer PC 9 pins RXD Input 2 3 TXD Output 3 2 GND Ground 5 5 Boardrate Default Boar...

Страница 6: ...ely before take it off the balance Maintenance Trouble shooting and solutions Phenomenon Possible Reason Solution Upper Line Over Load Re calibrate the Balance Under Line_ _ _ _ Overload or loadcell b...

Страница 7: ...echnology Limited Shanghai Drawell Scientific Instrument Co Ltd Add Suite 1506 Lane581 XiuChuan Rd PuDong New Area Shanghai China Tel 0086 21 50966080 Fax 0086 21 50966080 Web www drawell com cn Email...

Отзывы: