V

. Precautions

When no lighting is needed in the chamber, please turn off the light so as not to affect

the temperature of the upper layer. Turn off the power supply before changing the light

tube.

Handle with care. The angle between the instrument and the ground shall not be less

than 45°.

There is a water outlet pipe behind the equipment. When the inside temperature is

low, a small amount of water will be discharged. Please use a pipe to connect to the

container or sewer.

Do not use acid or alkali and other corrosive articles to wipe the surface. The inside

chamber can be cleaned regularly with dry cloth.

When the set temperature is lower than the room temperature, the over temperature

alarm will be generated if the door opening time is too long, which is not a fault.

When change the fuse tube, please cut off the power sup

ply and replace the one

with the same model and specification.

Fans are installed in the operation room. Don’t put fingers or any objects into the

cover. Please cut off the power supply before maintenance.

Please turn off the power switch when stop using.

Please do not put inflammable, explosive or toxic, strong acid and strong alkali

Addr

0

32

Local communication
address

——

SPL

LRV

SPH

Low limit of temperature
setting

——

SPH

SPL

URV

High limit of temperature
setting

——

Содержание DW-LBI- 80

Страница 1: ...International Technology Limited Chongqing Drawell Instrument Co Ltd Shanghai Drawell Scientific Instrument Co Ltd Chongqing Center Suite 2705 Building No 12 Shiyou Road No 1 Yuzhong District Chongqi...

Страница 2: ...3 63268643 Email sales05 drawell com cn Contents I Application 3 II Technical Specifications 3 III Installation requirements 3 IV Operation Method 4 V Precautions 6 VI Failure handling methods 7 VII T...

Страница 3: ...in a constant temperature environment and the recommended temperature difference is 23 5 Model DW LBI 80 DW LBI 150 DW LBI 200 DW LBI 250 DW LBI 300 DW LBI 400 Chamber Volume 80L 150L 200L 250L 300L...

Страница 4: ...finished running it will continue to run at the breakpoint of the last program In the normal state the upper row will display the measured temperature and the lower row will display the temperature s...

Страница 5: ...ill display the prompt and the lower row will display the parameter values see the attached table for details of each parameter After setting the parameter long press OK key for 5 seconds to exit the...

Страница 6: ...d or alkali and other corrosive articles to wipe the surface The inside chamber can be cleaned regularly with dry cloth When the set temperature is lower than the room temperature the over temperature...

Страница 7: ...st setting temperature The temperature controller is broken Change the temperature controller The cable is loose Tighten the cable Timing setting is incorrect Reset or cancel timing Big deviation of t...

Страница 8: ...t work normally during warranty period our company is responsible for free repair or replacement of product parts Beyond the warranty we try our best to provide convenience for users IX Packing List W...

Страница 9: ...tional Technology Limited Chongqing Drawell Instrument CO Ltd Add Suite 2705 Building No 12 Shiyou Road No 1 Yuzhong District Chongqing China Tel 0086 023 63268643 Shanghai Drawell Scientific Instrume...

Отзывы: