Draper SLX14 Скачать руководство пользователя страница 3

Scissor Lift SLX by Draper

 

page 3 of 7

Installing Optional Ceiling Closure

  If your Scissor Lift SLX is equipped with optional ceiling closure, it can be used 

as is, or in conjunction with a square of existing ceiling tile (see Fig. 5)

.

1

  If installing with ceiling tile, you may need to cut tile so that its overall  

  dimensions are the same as (or slightly less than) the closure panel. Place tile  

  into trim frame. Lay closure panel on top (back side) of ceiling tile, and tighten  

  screws to hold in place.

2

  Attach provided angle brackets to side of Bottom Panel of Scissor Lift SLX.

3

 Attach 

5

/

16

" threaded rods to angle bracket.

4

  Run unit “up” until bottom pan stops at highest position. Mark position on 

5

/

16

"  

  rods even with ceiling level and cut to length (remove from pan if convenient).

5

  Run unit “down” until bottom pan stops at “show” position.

6

  Attach closure to lower end of 

5

/

16

" rods by slipping into four corner slots and  

  secure with nuts above and below slots.

Caution: Make sure nuts are completely tightened.

7

  Run unit “up” again to highest position. Measure distance by which panel fails to  

  reach required “closed” height for surrounding ceiling.

8

  Run unit “down” then re-adjust mounting of 

5

/

16

" rods in traveling grid to raise  

  panel required distance.

9

  Test unit operation to confirm that panel will stop in closed position just before  

  touching ceiling.

Caution: DO NOT hang from, "ride" or pull down on the unit. This could 

create a failure and cause damage and/or injury.

PLEASE NOTE: Immediately upon completion of the surrounding ceiling, 

unit should be operated to confirm that optional ceiling closure panel by 

Draper or by others stops 

1

/

8

" short of touching ceiling in closed position. 

If closure panel touches, the motor may continue operating after the lift is 

closed. If it continues to cycle once the lift is closed, a motor failure may 

occur.

www.draperinc.com

(765) 987-7999

Installing Optional Ceiling Trim Kit

  The Scissor Lift SLX is available with a ceiling trim kit, which consists of 

the lower section of the Environmental Air Space Housing and the optional 

closure panel 

(see Fig. 6).

 Install Scissor Lift SLX as previously described in these instructions.

 Install bottom section of Environmental Air Space housing and Trim Ring in  

  opening. This can be accomplished by suspending with wire, or by mounting  

  directly to the ceiling joists (if space permits).

 Install projector and attach optional ceiling closure to Scissor Lift SLX,  

  according to the instructions included in this document.

Ceiling tile

(by others)

Lower section of

Environmental Air

Space Housing

Trim Ring

1

2

3

8

9

7

4

7

5

6

  Item  Qty 

Part Number 

Description

 

1

 

C028.546 

Frame, SLX Closure Trim

 

2

 

C044.181.07SA 

Panel, SLX Assembled Closure

 

3

 

C002.845.07SA 

Bracket, SLX Closure

 

4

 4  C077.035.49  Rod 

3

/

8

"-16 x 17

7

/

8

" L Threaded , Zinc

 

5

 

C013.050 

Washer .375 I.D. x .875" O.D.

   

 

 

x .064" TK GRD 2 Zinc Flat

 

6

 

C020.082 

Screw, 10-16 X ½" 6 Lobe

   

 

 

Truss Head AB E-White

 

7

 16  C018.027 

Nut, 

3

/

8

"-16 Hex GRD 2 NSF

 

8

 4  C020.322  Screw, 

5

/

16

"-18 x ¾" Long Grade 5 HH Zinc

 

9

 4  C018.045 

Nut, 

5

/

16

"-18 Zinc Hex KEPS

Installing Projector Using Universal Projector Mount

  The universal projector mount includes:

  -2 x long arms

  -4 x short arms

  -4 x M3, 4 x M4, 4 x M5 and 4 x M6 mounting bolts (30mm in length)

  -4 spacers (½" [13 mm], 

5

/

8

" [16 mm], ¾" [19 mm], 

7

/

8

" [22 mm])

1

 Determine which size mounting bolts suit your projector, and set others  

  aside. They are no longer required. If your projector has only three  

  mounting holes, set aside one of the mounting arms (see Fig. 3).

2

 Attach the appropriate mounting arms to the rectangular plate via center  

  bolt. Spread out the arms so each end is over one of the mounting holes.

3

 Connect projector mounting arms.

4

 Tighten the mounting bolts.

5

 Use the ¼" (6.35 mm)-20 bolts and springs which hold the rectangular  

  plate to the bottom pan to adjust roll and tilt (the springs will ensure that the  

  projector is held still during motion). The center 

5

/

16

" (8 mm) bolt provides  

  Yaw adjustment (see Fig. 4).

Detail: ¼" (6.35 mm)-20
Bolts and Spring 

¼" (6.35 mm)-20

Bolt and Washer

Spring

Figure 4

Figure 5

Figure 6

For Additional Safety:

1

  Be sure the nuts that attach the threaded  

  rods to the closure panel are tight.

2

  Wrap a plastic wire tie around the mounting  

  tab and the threaded rod at all four corners  

  of the closure panel (see drawing).

Please Note: Do NOT use a  

paper-covered or similar wire tie— 

use only plastic wire ties for  

maximum safety.

Scissor Lift SLX Inspection and Maintenance

  Draper recommends inspecting the Scissor Lift SLX at least annually or 

every 300 cycles—whichever comes first.

  A recommended maintenance schedule includes:

  -Cables: Check for fraying.

  -Drive Chain: Check for rust, breaks, secure attachment.

  -Fasteners along scissor arm assemblies: Make sure they are not loose. If  

   any are loose, hand tighten the nuts. 

(Please Note: there is no need to  

    tighten nut in the top scissor which slides back and forth in the side slot in  

   the lift. Tightening this fasteners assembly will cause the unit to lock up  

   and lead to damage to the unit.)

  -Closure: Make sure threaded rod remains seated firmly in the closure  

   panel corners, and that nuts remain tight. If they are loose, tighten them.

Содержание SLX14

Страница 1: ... to the Scissor Lift SLX for Electrical Connections Unit operates on 110 120V AC 60 Hz current Opening the electrical box exposes terminals for field connections Unit is shipped with internal wiring complete Wire to connect unit to power supply should be furnished by installer Connections should be made in accordance with wiring diagram and wiring should comply with national and local electrical c...

Страница 2: ... the mount pre installed you will need to install a new Projector Pan which includes the Universal Projector Mount s rectangular plate 1 Lower unit until the Bottom Pan is resting on a tabletop or other stable and sturdy surface 2 Remove Lifting Cable Bar from Bottom Pan see Fig 2 3 Remove bolts holding Projector Pan to Bottom Pan see Fig 2 4 Remove Projector Pan and set aside 5 Place new Projecto...

Страница 3: ...tions included in this document Ceiling tile by others Lower section of Environmental Air Space Housing Trim Ring 1 2 3 8 9 7 4 7 5 6 Item Qty Part Number Description 1 1 C028 546 Frame SLX Closure Trim 2 1 C044 181 07SA Panel SLX Assembled Closure 3 2 C002 845 07SA Bracket SLX Closure 4 4 C077 035 49 Rod 3 8 16 x 177 8 L Threaded Zinc 5 8 C013 050 Washer 375 I D x 875 O D x 064 TK GRD 2 Zinc Flat...

Страница 4: ... Position has been set See the operation above where Show Position is not yet set Remember that clearing and setting the Show Position does not affect the closed position limits Adjustments CAUTION Be sure all switches are in Off position before adjusting limit switch Always be prepared to shut lift off manually when new adjustment is being tested Please refer to wiring diagram Caution The mainten...

Страница 5: ... Switch BK RD BL Motor BL WH WH WH 125V 10A Outlet BK BK WH GN N 110 120 Vac Supply Dashed wiring by electrician RD WH BK RD WH WH RD BK WH RD Encoder Low voltage wiring by others Low Voltage Trigger 6 24 VDC Wall Switch Key Switch RP RQ Bus Ports for remote controls such as Eye Port for IR Eye RF Receiver LED Wall Switch and RS232 ...

Страница 6: ...ble A 357 16 371 16 42 36 3911 16 42 35 19 16 1 8 Top View Front View Side View Scissor Lift SLX Dimensions Table A Closed Extended Model Height Height SLX10 141 16 10 7 SLX14 165 16 14 2 SLX17 189 16 17 8 SLX21 2013 16 21 3 SLX24 231 16 24 9 SLX28 255 16 28 5 5 20 41 48 22 19 41 Front Back View Side View ...

Страница 7: ...ber Description 1 1 C028 544 02SA Frame SLX Plenum 2 1 C028 545 07SA Frame SLX Trim Ring 3 4 C044 178SA Panel SLX Plenum Side 4 4 C044 180SA Panel SLX Plenum End 5 2 C044 179SA Panel SLX Middle End 6 2 C044 177SA Panel SLX Plenum Middle Side 7 1 C095 123SA Cover SLX Plenum 8 28 C020 325 Screw 8 32 x 3 8 Type 1 HWH 9 40 C018 051 Nut 8 32 Zinc Hex KEPS 10 12 C013 070 Washer 188 I D x 5 O D x 07 TK N...