Draper Signature V Series Скачать руководство пользователя страница 2

Case Dimensions & Methods of Installation

SCREEN SIZE 

CASE SIZE

Total Drop <156" or viewing width <144" 

Small

Total drop >156" or viewing width >144" 

Large

Wiring Diagrams

Signature/Series E & V by Draper

Page 2 of 2

NOTE: Viewing surface shown is Series V with tab tensioning. 

Series E, without tab tensioning, is also available.

Tab-Tension Adjustment 

Procedure for Signature/Series V

1

  Determine which side requires adjustment.

2

  Secure dowel with one hand.

Caution: Do not touch or bend surface.

3

  Using Phillips-head screwdriver, depress  

  spring-loaded adjustment screw  

  (see drawing) and slowly turn  

  clockwise to tighten tension, or  

  counterclockwise to loosen tension.  

  The screw adjusts in ¼ turn increments.  

  Adjust only 

one increment

 (¼ turn).

4

  If problem is not corrected, leave screen in  

  position for 24 hours to allow surface  

  material to stretch into position.

5

  If problem still is not corrected, repeat steps 2 and 3.

Dowel

Adjustment

Screw

Tensioning

Cable

Single Station Control 

Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green/Yellow (Ground)

Dashed wiring  
by electrician 

Control 
switch 

Single gang box by others 
Min. 4" x 2

 

1

/

8

" x 1

 

7

/

8

" deep 

Blue 

Black 

Red 

Location of key 
operated on-off  
switch if furnished 

To 110-120V Line 

Multiple Station Control 

Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green/Yellow (Ground)

Dashed wiring  
by electrician 

Red 

Red 

Black 

Blue 

Blue 

Cap off with wire  
nut and tape 

Black 

Red 

Blue 

Black 

Single gang box by others 
Min. 4" x 2

 

1

/

8

" x 1

 

7

/

8

" deep. 

3 shown. More or less equally 
feasible. 

Location of key 
operated on-off  
switch if furnished 

To 110-120V Line 

www.draperinc.com

(765) 987-7999

Two-Way Serial Communication (RS232) with MC1

See separate Serial Communication-RS232 Instruc-
tion sheet for enabling RS232 with the MC1.

3 Button Wall Switch 

DOWN - Black

COM - White

UP - Red

White-Common to screen & 110-120V AC Neutral

Red-to screen (directional)

Brown-to screen (directional)

Yellow-to 110-120V AC-Hot

Black-to 110-120V AC-Hot

Green-Ground

Eye Port

 for IR Eye, RF Receiver or LED

Wall Switch. For more than one of 

these, a splitter is required.

Aux Port 

for connecting additional LVC-III 

modules (up to six total can be linked-

connect from Aux to Eye).

Dashed wiring by electrician

Low voltage wiring by others

White (Common)

Red (Up)

Black (Down)

Green (Ground)

Location of key

operated on-off 

switch if furnished

To

110-120V

Line

Internal Screen Wiring

STOP

Control 

Switches

24v DC

STOP

Low Voltage & Wireless Control

RS232 Data FROM Control System 

RS232 Data TO Control System 

Signal Ground & Manual Switch Common 

Manual Switch Down 

Manual Switch Up 

White-Common to screen & 110-120V AC Neutral 

Red-to Screen (directional) 

Brown-to Screen (directional) 

Black-Hot to 110-120V AC 

Green/Yellow-Ground 

Fuse 

Program LED 

Eye Port for IR Eye. For RF Receiver or LED 

Wall Switch, a Splitter and a Power Supply 

is required. Plug RF Receiver or LED Wall  

Switch and Power Supply into splitter, then  

run cable from Splitter to MC1 Eye Port. 

Low Voltage Wiring by others 

AC Wiring by electrician 

MC1 

White (Common)

Red (Up)

Black (Down)

Green/Yellow (Gnd)

Internal Screen Wiring 

 

Location of key 

operated on-off  

switch if furnished 

To 

110-120V 

Line 

STOP 

Control  

Switches 

24v DC 

STOP 

Case length

1

1

/

2

" Typ

Viewing surface

2

1

/

8

"

A

  Series 

A

 E-small case  3

3

/

16

"

 E-large case  4

1

/

2

"

 

Varies

Ceiling grid 

and tile

(by others)

9

1

/

8

"

6"

9¾"

Audience

Electrical connection

to internal splice box

on left end of case. 

7

/

8

"

knockout for 

1

/

2

" conduit.

J-Box cover located under 

splice box.

Shown with

3

/

8

" threaded

rod (provided

by others).

Ceiling grid and tile

(by others)

9

1

/

8

6" 

11" 

Audience 

Electrical connection 

to internal splice box 

on left end of case. 

7

/

8

knockout for 

1

/

2

" conduit. 

J-Box cover located under  

splice box. 

Shown with

3

/

8

" threaded

rod (provided

by others).

 

Ceiling grid and tile 

(by others) 

Small Signature Case

Large Signature Case

Caution: Do not remove the roller assembly from the case unless 

necessary for repairs. If the roller assembly is removed, be sure mo-

tor is fully re-seated in the bracket, and re-secure it carefully with the 

motor retaining spring and screw (see diagram below).

Please note: Maximum 

torque for tightening 

screw is 5 lb-inches.

Please Note: Do not wire motors in parallel.

Brackets evenly spaced along screen case