Draper Rolleramic Electric Projection Screen Скачать руководство пользователя страница 2

Rolleramic Wiring Diagrams

Cond

u

it 

connection

L = 

W

+24" (thro

u

gh 12

'

 x 12

'

)

L = 

W

+30" (o

v

er 12

'

 x 12

'

)

Thro

u

gh 12

'

 x 12

'

    14¾"

O

v

er 12

'

 x 12

'

    21¼"

Access 

Door

Bottom 

b

oard

Case 

¾" thick

4" - 4

1

/

8

"

Opening for fa

b

ric

Bottom

Front

Fa

b

ric 

w

idth – 

W

Screen
s

u

rface

4

5

/

8

"

9

1

/

8

"

9

1

/

8

"

9

5

/

8

"

9

5

/

8

"

11

1

/

2

"

Page 2 of 2

Case Dimensions 

Rolleramic by Draper

Rolleramics over 12' x 12' 
have a blue wire lead 
instead of a black wire lead 
coming from the motor.

Single Station Control

Junction box at 
left end of screen

Internal Screen Wiring

White (Common)

Red (Down)

Black, or Blue (Up)

Green (Ground)

Dashed wiring 
by electrician

Control
switch

Single gang box by others
Min. 4" x 2 1/8" x 1 7/8" deep

Blue

Black

Red

Location of key
operated on-off 
switch if furnished

To 110-120V Line

Multiple Station Control

Junction box at 
left end of screen

Internal Screen Wiring

White (Common)

Red (Down)

Black, or Blue (Up)

Green (Ground)

Dashed wiring 
by electrician

Red

Red

Black

Blue

Blue

Cap off with wire 
nut and tape

Black

Red

Blue

Black

Single gang box by others
Min. 4" x 2 1/8" x 1 7/8" deep.
3 shown. More or less equally
feasible.

Location of key
operated on-off 
switch if furnished

To 110-120V Line

For s

u

spended mo

u

nt. 

For 

w

all mo

u

nt

6

3

/

8

"

1

3

/

8

"

Rolleramic Mounting Bracket

www.draperinc.com

(765) 987-7999

Two-Way Serial Communication 

(RS232) with MC1

See separate Serial Communication-
RS232 Instruction sheet for enabling 
RS232 with the MC1.

3 Button Wall Switch 
DOWN - Red
COM - White
UP - Black

White-Common to screen & 110-120V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 110-120V AC-Hot
Black-to 110-120V AC-Hot
Green-Ground

Eye Port

 for IR Eye, RF Receiver or LED

Wall Switch. For more than one of 
these, a splitter is required.

Aux Port 

for connecting additional LVC-III 

modules (up to six total can be linked-
connect from Aux to Eye).

Dashed wiring by electrician

Low voltage wiring by others

White (Common)
Red (Down)
Black (Up)
Green (Ground)

Internal Screen Wiring

Location of key
operated on-off 
switch if furnished

To

110-120V

Line

STOP

Control 
Switches
24v DC

STOP

Low Voltage & Wireless Control

RS232 Data FR

OM Control System

RS232 Data T

O

 Control System

Signal Ground & Man

u

al Switch Common

Man

ual Switch Up

Man

ual Switch Do

wn

White-Common to screen & 110-120V A

C

 Neutr

a

l

Red-to Screen (directional)

Bro

wn-to Screen (directional)

Blac

k-Hot to 110-120V A

C

Green/Y

e

llo

w

-Ground

Fuse

Program LED

Ey

e P

o

rt

 f

o

r IR Ey

e

. F

o

r RF Receiv

er or LED

W

a

ll Switch, a Splitter and a P

o

w

e

r Supply

is required.

 Plug RF Receiv

e

r or LED W

all 

Switch and P

o

w

e

r Supply into splitter

, then 

ru

n cab

le from Splitter to MC1 Ey

e P

o

rt

.

Lo

w V

o

ltage Wir

ing b

y others

A

C

 Wir

ing b

y electr

ician

MC1

White (Common)

Red (Do

w

n)

Blac

k (Up)

Green (Ground)

Inter

n

al Screen Wir

ing

Location of k

ey

oper

ated on-off 

sw

itch if fur

nished

To

110-120V

Line

ST

OP

Control 

Switches

24v DC

ST

OP

Please Note: Mount the case using the two end brackets fi rst. If 
a center bracket is provided, mount it last. The center bracket is 
designed to prevent sagging of the case, and must be mounted 
so that it is level with the others and does not force the screen 
case up. Make sure the top of the screen case's bottom board at 
no point touches the roller/viewing surface.

Отзывы: