Case Dimensions
Tab-Tension Adjustment Procedure
for Premier
Determine which side requires adjustment.
Secure dowel with one hand.
Caution: Do not touch or bend surface.
Using Phillips-head screwdriver,
depress spring-loaded adjustment screw
(see drawing) and slowly turn clockwise to
tighten tension, or counterclockwise to
loosen tension. The screw adjusts in
¼ turn increments. Adjust only
one
increment
(¼ turn).
If problem is not corrected, leave screen in
position for 24 hours to allow surface
material to stretch into position.
If problem still is not corrected, repeat steps 2 and 3.
Dowel
Adjustment
Screw
Tensioning
Cable
5
1
/
4
"
1
13
/
16
"
5
7
/
8
"
1"
15
/
16
"
7
/
8
" dia.
electrical
connection
hole
Mounting
hole
2
1
/
8
"
Types of Installation
Appropriate hardware
provided by installer.
Suspended
Wall
Appropriate hardware
provided by installer.
If using "S"
Hooks )by
others), be
sure to crimp
both ends
of the "S"
Hooks.
Premier by Draper
Page 3 of 4
www.draperinc.com
(765) 987-7999
the +5
V
UP 5V COM DWN
U
P
D
O
W
N
C
O
M
M
O
N
5V
Motor Data Cable
plugged in here
Built-in Low Voltage Motor: Switch-to-Motor—Dry Contacts or Data Cable connection
Please Note:
This Splitter/Jack
is located inside the motor-end
endcap of your screen. To ac-
cess, remove access panel from
endcap.
Back of wall switch.
Please Note:
Although both Dry
Contact and Data Cable connections
are shown, you should only use one
connection type per motor.
Data Cables to switches or
to additional motors can be
plugged into any of the three
open jacks.
Please Note: 5V DC must be
connected to be able to set
limits using the wall switch.
Optional Ceiling Opening Trim Kit
(Dims-Side View)
2
1
/
8
"
2
1
/
16
"
4"
6
3
/
4
"
1
1
/
16
"
8"