Installation Instructions
Panel Track FlexShade by Draper
Copyright © 2015 Draper Inc. Form PanelTrackFlexShade_Inst15
Printed in U.S.A.
If you encounter any difficulties installing or servicing your Panel Track FlexShade, call your
dealer or Draper, Inc. in Spiceland, Indiana, 765-987-7999, or fax 765-987-7142.
Warning
1
Inspect all boxes to make sure you have received the proper parts.
2
Open cartons lengthwise.
3
All brackets, fascia, and other hardware must be installed level. Panel
Track must be level.
4
Please read the following installation guidelines thoroughly and
follow them carefully. Failure to do so may cause product to fall or
otherwise fail, and invalidates warranty.
Continued on reverse side
Wall Mounting
1
Mark mounting surface for placement of mounting brackets. If two brackets
are provided, they should be attached to the mounting surface about 4" in
from each end of the track. If there are three or more brackets, one should
be attached to the mounting surface about 4" from each end of the track,
and the remaining brackets should be spaced evenly between them.
Caution: Before mounting, verify measurements, and ensure the
brackets are installed at the correct locations, and high enough to allow
1" of clearance between the fabric panels and the floor.
2
Drill small starter hole (if necessary) in mounting surface.
3
Mount brackets using appropriate fasteners for surface.
Please Note: The installer is responsible for selecting mounting hard-
ware appropriate for site conditions and product weight.
4
Attach track to the mounting brackets. Place the mounting locking mecha-
nisms into the extrusions along the top of the track, and rotate until they
lock in place (see Fig. 2).
Caution: Be careful not to pinch your fingers when closing or opening
the locking mechanism (see Fig. 3).
Figure 3
Ceiling Mounting
1
Mark mounting surface for placement of ceiling brackets. If two brackets
are provided, they should be attached to the mounting surface about 4" in
from each end of the track. If there are three or more brackets, one should
be attached to the ceiling about 4" from each end of the track, and the
remaining brackets should be spaced evenly between them.
Caution: Before mounting, verify measurements, and ensure the
ceiling brackets are installed at the correct locations. 1" of clearance is
required between the fabric panels and the floor.
2
Drill small starter hole (if necessary) in mounting surface.
3
Mount brackets using appropriate fasteners for surface (see Fig. 4).
Fabric Panel Attachment
1
Attach fabric panels to slliding Fabric Panel Attachemnt Arms using the
affixed Hook & Loop attachment strip along the top of each panel
(see Fig. 7).
Figure 4
4
Attach track to the mounting brackets. Place the mounting locking mecha-
nisms into the extrusions along the top of the track, and rotate until they
lock in place (see Fig. 5).
Please Note: The installer is responsible for selecting mounting hard-
ware appropriate for site conditions and product weight.
Figure 5
Please note: Shown from above with ceiling removed from view for clarity
Caution: Be careful not to pinch your fingers when closing or opening
the locking mechanism (see Fig. 6).
Figure 6
VELCRO® Strips
Figure 7
Caution: Beware
of pinch points.
Caution: Beware
of pinch points.
Figure 1
Tighten to lock
in position.
Please Note: Hook &
Loop attachment strips
on sliding Fabric Panel
Attachment Arms must
be facing into the room.
Figure 2
Please Note: Hook & Loop attach-
ment strips on sliding Fabric Panel
Attachment Arms must be facing
into the room.