NOTE: Test shade operation
If shade direction does not
correspond with the switch
orientation, turn power back
off and switch the
red
and
black
wires from the motor to the switch.
Do not wire motors in parallel without
written permission from Draper.
Controls & System Overview
Sonesse
®
120VAC Motors
W
B
R
G
B
Control
Switch
Single Gang
Box (by others)
120V
MOTOR
110-120V Line
Dashed Wiring
by Electrician
M12 Connector
for 3-Wire Motors
2 - WHITE
1 - BLACK
4 - GREEN
3 - NOT USED
2 - WHITE
2 - WHITE
1 - BLACK
3 - NOT USED
4 - GREEN
2 - WHITE
To Switch
& 120VAC
To
Motor
60"
1.5 m
Standard
12"
30.5 cm
Standard
W B G
Ø
0.61"
15.5 mm
2 - WHITE
1 - BLACK
3 - RED
4 - GREEN
2 - WHITE
2 - WHITE
1 - BLACK
3 - RED
4 - GREEN
2 - WHITE
W B R G
To Switch
& 120VAC
To
Motor
60"
1.5 m
Standard
12"
30.5 cm
Standard
M12 Connector
for 4-Wire Motors
Ø
0.61"
15.5 mm
Dashed Wiring
by Electrician
Controls & System Overview
Sonesse
®
RTS 120VAC Motors
M12 Connector
B W G
RTS
MOTOR
120V
110-120V Line
Decora RTS
Wireless Keypad
Telis 1
RF Remote
STOP
Data Cable Pin-Out - RJ45 Connector
MOTOR Pin-Out - RJ9 Connector
4 - GROUND - (BROWN)
3 - POWER + (BLUE)
2 - DATA - (ORANGE)
1 - DATA + (ORANGE/WHITE)
1 - DATA + (ORANGE/WHITE)
2 - DATA - (ORANGE)
3 - N/A (GREEN/WHITE)
4 - POWER + (BLUE)
5 - POWER + (BLUE/WHITE)
6 - N/A (GREEN)
7 - GROUND - (BROWN/WHITE)
8 - GROUND - (BROWN)
Data Hub
Bus Power
Supply
Controls & System Overview
Sonesse
®
RS485 120VAC Motors
BUS OUT
to next
DATA HUB
BUS IN
STOP
Wall Switch
110V
Outlet
LAN
Data Cable
with RJ45
Connector
M12
Connectors
RS485
120VAC
Motor
RS485
120VAC
Motor
B W G
110-120V Line
B W G
110-120V Line
DATA
CABLES
Dashed Wiring
by Electrician
Sonesse
®
is a registered trademark of Somfy
®
Systems, Inc.
page 10 of 12
Motorized FlexShade
®
(Coupled)