Draper Access Fit Скачать руководство пользователя страница 1

Remove Screws 
from both ends 
of Screen Housing

Access 
Panel Door 
pivot on Hinges

OPEN 

ACCESS 

PANEL

CLOSED 

ACCESS P

ANEL

SCREEN

HOUSING

A

TTACHING

 

BRACKETS

Insert pin in top 

slot and push up

Rotate bracket

clockwise to lock 

bracket in place

1

2

E

NGAGEMENT

 B

RACKET

WITH

 B

ALL

 D

ETENT

will snap into Access 

Panel Support Bracket.

A

CCESS

 P

ANEL

 

S

UPPORT

 B

RACKET

CENTER of CASE

CENTER of CASE

Bottom Access Panel Installation/Removal

Bottom access panel is secured to the screen housing by two screws (one on 

each end), and is held in the closed position by engagement brackets with ball 

detents that snap into case support brackets.  

To remove the Access Panel:

1

 Remove screws from both ends of screen housing (Fig. 4). 

2

 Pull down on the access panel until the ball detents on the engagement 

  bracket have disengaged from the support bracket. 

3

 Repeat Step 

2

 for all brackets along the length of the screen housing.

4

 The access panel will be free to pivot downward. It will remain attached to  

  the lower inside edge of the screen housing by several steel hinges.  

Caution: For larger sizes Step 

5

 requires two people to perform safely.

5

 Press up on access panel and pull toward the front of the screen housing to  

  disengage hinges and remove access panel. 

To Remove/Install Support Brackets:

Installation/Operating Instructions

Access Fit 220V Electric Projection Screen by Draper

Copyright © 2015 Draper Inc. 

Form AccessFit220V_Inst15     Printed in U.S.A

Hanging Screen 

When locating viewing surface and checking clearance for screen operation, 

remember surface is centered in the length of the case. Regardless of 

mounting method used, the following points apply: 

1

 Mounting brackets are shipped attached to the case. Engage each bracket  

  with top of housing as shown below and tighten set screws. 

2

 Screen should be positively and securely supported so that vibration or  

  even abusive pulling on viewing surface will not weaken installation.

Please Note: A Hoisting Bracket is included on each end of the case to 

aid in overhead installation of the Access Fit case.

3

 Installer must insure that fasteners used are of adequate strength and  

  suitable for the mounting surface chosen. Supporting hardware (chains,  

  cables, 9.5mm rods, etc.) must be essentially vertical.

4

 Entire bottom of case must be readily accessible  

  after installation is complete.

5

 Front, back and top of case must be straight— 

  not forced to warp or bow. 

6

 If case is painted on location, removal of 

  roller/fabric assembly is recommended 

  prior to painting. If not removed, slot 

  on bottom of case should be shielded  

  to protect viewing surface from paint  

 splatters/overspray.

7

 Do not seal unit in ceiling until  

  electrical connections have been made  

  and screen has been operated successfully.

Electrical Connections

Screen operates on 220V, 50 hz., 1.1 amp current draw.  

Duty Cycle: ON 28 seconds /OFF 4 minutes.

Junction box is located just above the bottom access panel at left end of 

screen (standard, right end may be specified). 

Remove the bottom access panel for access to the junction box cover. (See 

Bottom Access Panel Removal instructions below). Remove two (2) hex head 

screws that secure the cover to the junction box to expose the red, black, and 

white pigtail leads and the green ground wire per wiring diagram on page 4.

If optional low voltage control is specified and factory installed, please refer to 

wiring diagrams on page 4.

Screen is shipped with internal wiring complete and control switch(es) fully 

boxed. Wire to connect screen to switch(es) and switch(es) to power supply 

should be furnished by installer. Connections should be made in accordance 

with attached wiring diagram, and wiring should comply with national and 

local electrical codes.

All operating switches should be “off” before power is connected.

Caution

1

 Read instructions through completely before proceeding; keep them  

  for future reference. Follow instructions carefully. Installation contrary to  

  instructions invalidates warranty. Care in mounting and correct operation  

  will mean long and satisfactory service from your Draper screen.

2

 Before removing screen from crate, check for damage and to make sure  

  all parts are included.

3

 Allow enough access to remove front cover should fabric become  

  damaged or should other service be required.

4

 Screen should be installed level (using a carpenter’s level).

5

 Nothing should be fastened to screen dowel or viewing surface.

6

 Operating switch(es) is packed separately in screen carton. Do not  

  discard with packing material.

7

 Screen operates on 220V, 50 Hz. 1.1 amp current draw.

NOTE

: Screen has been thoroughly inspected and tested at factory and  

found to be operating properly prior to shipment.

 

 

 

 

If you encounter any difficulties installing or servicing your Access Fit screen, call  

your dealer or Draper, Inc., in Spiceland, Indiana, 765/987-7999 or fax 765/987-7142.

Suitable for use in environmental air space in accordance with Section 

300-22(c) of the National Electrical Code, and Sections 2-128, 12-010(3) and 

12-100 of the Canadian Electrical Code, Part 1, CSA C22.1.

Dowel

Shipping

Bracket

Remove 

shipping 

brackets before 

operating screen.

Access Fit 

case as seen 

from below

Bottom flange of 
Access housing

Bottom Access Panel Door

Caution: Beware of pinch points at ends of closure

US Patent Nos. 

6,137,629; 6,421,175; 

6,532,109; 6,816,308; 

7,559,707

These instructions are meant as a guide only. They do not imply any responsibility on the 

part of the manufacturer for improper installation or faulty workmanship at the jobsite.

1

With typical installation, brackets may be angled to meet installation requirements. 

Typical 

Installation

1

22mm

ELECTRICAL

CUTOUT

Alternate  

Installation  

(additional set of  

brackets required  

but not included)

7

/

8

"

 

ELECTRICAL

CUTOUT

Figure

Figure

Figure

Figure

Figure

Отзывы: