 Screen limits are factory set. Instructions below for  

minor adjustments only. Please check with Draper prior to resetting 

screen limits.

Please Note:

 If Access Fit E/V is “Right Hand Motor” or “Waterfall,” the 

WHITE/DOWN 

(I)

 and YELLOW/UP 

(II)

 limit screws are reversed 

(Fig. 9)

.

Section 8 -

 Limit Adjustments

Section 8.1 - Limit Adjustments 

Section 8.1.1 - "Down" Limit Adjustment  

(requires a 

5

/

32

" (4 mm) Allen wrench)

To Reduce Screen Drop:
1. 

Raise screen surface approximately 

1' 

(30 cm)

 above desired setting and 

turn off.

2. 

Turn DOWN 

(I)

 limit screw clockwise 

(3 screw turns = 

1

/

2

 roller revolution)

.

3. 

Test by lowering screen. Repeat 

steps 1 & 2 until desired position is 

reached.

To Increase Screen Drop:
1. 

Lower screen to down limit.

2. 

With down switch on, turn DOWN 

(I)

 limit  

screw counterclockwise

 (3 screw turns =  

1

/

2

 roller revolution) 

to increase drop. 

3. 

Test by raising screen approximately  

1' 

(30 cm)

 then down to new down limit.

4. 

Repeat steps 2 and 3 until desired  

position reached.

  Caution: 

 

-  Be sure all switches are in “off” position before adjusting limit switches. 

 

-  Be prepared to shut off manually while testing.

 

-  Screen may be damaged by lowering it too far and exposing roller.

 

-  Motor must be installed so limit switches are pointed down.

Please Note:

 For Quiet Motor with alternate limit screws, WHITE screw = UP and  

RED screw = DOWN. 

However

, limits are reversed if surface is waterfall rolled.

Section 8.1.2 - "Up" Limit Adjustment

Section 8.2 - ILT Motors with Internal Low Voltage Control Limit Adjustments 

Please Note:

 Hold STOP button for 3-5 seconds while in programming 

mode to reverse motor direction.

Please Note:

 When ordering a motor with internal Low Voltage 

Controller, if case ships separately from contents, case  

includes 25' cable and special low voltage switch.

1. 

Connect ILT switch to motor via terminal blocks, or via modular port 

using four conductor modular cable. When using modular cable, 

cable connectors MUST NOT be crimped in reverse, as with standard 

telephone cable. 

(For Dry Contacts Wiring Diagram, see Section 12.)

2. 

Set slide switch to lower position. Hold DOWN button to move viewing 

surface to desired lower limit. If screen moves in opposite direction, 

release DOWN button and hold STOP button for 4 seconds. This 

reverses operation of UP and DOWN switches.

3. 

Move slider switch into center position. Wait several seconds.

Please Note:

 Move slider switch from down to up in one motion to set 

limits in same position.

4. 

Set slide switch to higher position. Move viewing surface to desired 

upper limit by holding UP button on wall switch. 

5. 

Return slide switch to center position to return to normal operation.

6. 

To set viewing surface to alternate format position, move viewing 

surface to desired position and press STOP button. Hold STOP button 

for at least 3 seconds to record position.

Please Note:

 Press and release UP button on switch to move screen to upper 

limit. Press and release DOWN button to move screen to lower limit.
•  While motor is in motion, press STOP button for less than 2 seconds to 

stop viewing surface at present position.

•  Once motor is stopped, press STOP button to move viewing surface to 

alternate format position.

•  Hold STOP button, when motor is at rest or in motion, for 3-5 seconds to 

record new alternate format position. 

•  Hold STOP button for 3-5 seconds while in programming mode to reverse 

motor direction.

If Screen Raises Too High:

1. 

Lower screen surface approx.  

1' below desired setting and  

turn off.

2. 

Turn UP 

(II)

 limit screw clockwise  

(3 screw turns = 

1

/

2

 roller 

revolution).

3. 

Test by advancing screen up.

4. 

Repeat steps 1 through 3 until 

desired position is reached.

If Screen Needs to Raise Higher:

1. 

Lower screen surface 

approx. 1' below 

desired setting and 

turn off.

2. 

With Up switch on, 

turn UP 

(II)

 limit screw 

counterclockwise 

(3 screw turns = 

1

/

2

 

roller revolution)

.

3. 

Repeat steps 1 and 2 

until desired position 

is reached. 

 Caution:

 DO NOT allow dowel to wrap over roller when operating screen! This could damage screen.

POSITION

FUNCTION

DOWN

Set LOWER limit

UP

Set UPPER limit

CENTER

Normal Operation

Please Note:

 5V DC must 

be connected to be able 

to set limits using wall 

switch.

POSITION

FUNCTION

DOWN

UP

CENTER

Set LOWER limit

Set UPPER limit

Normal Operation

To Motor

with

Internal

Low Voltage

Slide

Switch

Back View of Wall Switch

U

p

D

o

w

n

C

o

m

m

o

n

+

5V

DC

To Motor

with

Internal

Low Voltage

Figure 9

Left hand motor:

   White Socket—Down

   Yellow Socket—Up

Right hand motor:

   White Socket—Up

   Yellow Socket—Down

Left hand motor:

   White Socket—Up

   Yellow Socket—Down

Right hand motor:

   White Socket—Down

   Yellow Socket—Up

Left hand motor:

  White Socket—Down

  Yellow Socket—Up

Right hand motor:

  White Socket—Up

  Yellow Socket—Down

Waterfall Roll

Standard Roll

Motor

End

Audience

Side

Motor

End

Audience

Side

Reverse Roll

Motor

End

Back

Side

Access FIT E and V 220V

Electric projection screen

page 5 of 7

Содержание Access Fit Series

Страница 1: ...nt splatters overspray If you have any difficulties installing or servicing your Access Fit Screen call your dealer or Draper Inc Electrical Cutout Tab Tensioning V Dowel E Dowel Mounting Bracket Moun...

Страница 2: ...only by authorized and qualified personnel who have been trained in its safe and effective operation and understand its safety features 13 The safety features of the unit should never be disabled bypa...

Страница 3: ...visible from bottom of screen housing Please Note If snap ring is provided make sure it engages with motor If retaining clip is provided instead install to lock motor end in place 7 Support idler end...

Страница 4: ...usted limit switches stop screen automatically when fully up or fully down 24V CONTROL 3 button UP STOP DOWN switches stop at any point desired operate in any sequence Factory adjusted limit switches...

Страница 5: ...l seconds Please Note Move slider switch from down to up in one motion to set limits in same position 4 Set slide switch to higher position Move viewing surface to desired upper limit by holding UP bu...

Страница 6: ...There are several knock outs in the screen housing to allow the Leveling Bracket to be adjusted laterally up to 16 40 6cm in either direction Series E Viewing Surface Series V Viewing Surface Standard...

Страница 7: ...en Wiring Diagram Back of Wall Switch Back of Wall Switch Please Note 5V DC must be connected to set limits using the wall switch Dry Contacts Back of Wall Switch Back of Wall Switch MOTOR DATA CABLE...

Отзывы: