CONNECTING YOUR PUMP TO THE POWER SUPPLY: (230V ONLY)

To eliminate the possibility of an electric shock, your pump has been fitted with a BS
approved, non-rewirable moulded plug and cable which incorporates a fuse, the value
of which is 3 amps. Should the fuse need to be replaced, an 

approved BS1362 fuse

must be used of the same rating, marked thus        . The fuse cover is detachable, never
use the plug with the cover omitted. If a replacement fuse cover is required, ensure it is
of the same colour as that visible on the pin face of the plug (i.e. red). Fuse covers are
available from your Draper Tools stockist.
If the fitted plug is not suitable, it should be cut off and destroyed. *The end of the
cable should now be suitably prepared and the correct type of plug fitted. See below.

WARNING:

A plug with bare flexible wires exposed is hazardous if engaged in a live power socket
outlet.

WARNING: THIS APPLIANCE MUST BE EARTHED.

Green and Yellow - Earth, Blue - Neutral, Brown - Live.
As these colours may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured green and yellow must be connected to the terminal in the
plug which is marked with the letter ‘E’ or by the earth symbol 

or coloured green

or green and yellow.
The wire which is coloured blue must be connected to the terminal which is marked
with the letter ‘N’ or coloured black or blue.
The wire which is coloured brown must be connected to the terminal which is marked
with the letter ‘L’ or coloured red or brown.

EXTENSION LEAD CHART:
Extension lead sizes shown assure a voltage drop of not more than 5% at rated
load of tool.

POWER SUPPLY

- 5 -

Ampere rating

3

6

10

13

(on name plate)

Extension cable length

7.5

0.75

0.75

1.0

1.25

15m

0.75

0.75

1.0

1.5

22.5m

0.75

0.75

1.0

1.5

30m

0.75

0.75

1.25

1.5

45m

0.75

1.25

1.5

2.5

Wire size mm

2

IMPORTANT: A residual current circuit breaker (RCD) must be used when pumping from
ponds or swimming pools and is recommended for all applications.

Содержание 54876

Страница 1: ...POND FILTRATION PUMP STOCK No 54876 PART No PFP3500 INSTRUCTIONS IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PRODUCT 11 2000 ...

Страница 2: ...ARATION OF CONFORMITY We Draper Tools Ltd Hursley Road Chandler s Ford Eastleigh Hampshire S053 1YF England Declare under our sole responsibility that the product Part No PFP3500 Stock No 54876 Description Pond Filtration Pump To which this declaration relates is in conformity with the following directive s 73 23 CEE 89 336 CEE and 93 68 CEE with reference to EN60335 2 41 JOHN DRAPER Managing Dire...

Страница 3: ...ir agent or contact Draper Tools Limited Hursley Road Chandler s Ford Eastleigh Hampshire SO53 1YF England Telephone 023 8026 6355 If upon inspection it is found that the fault occurring is due to defective materials or workmanship repairs will be carried out free of charge This guarantee does not apply to normal wear and tear nor does it cover any damage caused by misuse careless or unsafe handli...

Страница 4: ...electrician 4 Close supervision is necessary when any pump is used by or near children 5 To avoid injury do not contact moving parts or hot parts such as heaters reflectors lamp bulbs and the like 6 Always unplug a pump from an outlet when not in use before putting on or taking off parts and before cleaning Never yank cord to pull plug from outlet Grasp the plug and pull to disconnect 7 Do not use...

Страница 5: ...IANCE MUST BE EARTHED Green and Yellow Earth Blue Neutral Brown Live As these colours may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured green or green and yellow The wire which is coloure...

Страница 6: ...GETTING TO KNOWYOUR FILTRATION PUMP 6 1 Motor 2 Filter cover 3 Filter 4 Moulded plug and cable 5 Telescopic extension tube 6 Spray head 7 Waterfall flow control ...

Страница 7: ...tube The spray head must always be above the water level Place the pump on a solid and level platform FIG 1 WATER FLOW A waterfall or other water effect can be produced by connecting a hose to the tee joint on the telescopic tube The flow of water on the waterfall can be regulated by turning the teejoint FIG 2 Fig2 Fig1 ...

Страница 8: ...move the support base FIG 3 by pressing the four clamps located in the area of the feet take out the two sponges housed in the pump and wash them in fast running water 3 To clean the rotor you must first remove the pre chamber Take the pre chamber in the area of the two fins and pull it out vertically freed in this way the rotor can be removed and washed in water using a soft brush to remove the m...

Страница 9: ...Head Dome 2 YPFP R8308 55408 Telescopic Extension Tube 3 YPFP R50067 55409 Spray Head Three Tier 4 YPFP R3801 55410 Filter 2 5 YPFP R52500 BKA 55411 Rotor 6 YPFP R1444 55412 Rotor Cover SPARE PARTS LISTING STOCK No 54876 PART No PFP3500 PARTS LISTING DRAWING 06 2000 ...

Страница 10: ...NOTES 10 ...

Страница 11: ...NOTES 11 ...

Страница 12: ...26 6355 Fax 023 8026 0784 www draper co uk e mail sales draper co uk Published by Draper Tools Ltd No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior permission in writing from Draper Tools Ltd YOUR DRAPER STOCKIST ...

Отзывы: