![Draper 40218 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/draper/40218/40218_manual_2528866017.webp)
No power
Pump running but
not delivering water
Pump stops running,
due to thermal
overload coming into
operation
1. Fuse
2. Other
1. Insufficient water lever
2. Inlet clogged.
3. Hose crimped.
1. Solid jammed in pump.
2. Excessive water temp.
3. Pump ran dry
1. Reset/replace time delay fuse or
circuit breaker.
2. Return to service agent
1. Raise water level (where
applicable).
2. Clean.
3. Straighten host.
1. Remove obstruction
2. Water temp must not exceed 35°C.
3. Adjust float switch
12.1 TROUBLESHOOTING CHECKLIST
WARNING:
For your own safety, always turn the main switch on the machine "Off" and remove the plug from
the power supply before carrying out any servicing or maintenance.
12. TROUBLESHOOTING
- 17 -
Problem
Cause
Remedy