Draper 220V Envoy Скачать руководство пользователя страница 2

220V Envoy by Draper

Case Dimensions and Wiring Diagrams

Page 2 of 2

Standard

Construction

Offset

Construction

Fa

b

ric 

W

idth + 381 mm

V

ie

w

ing

s

u

rface

16
mm

57

mm

191

mm

Cond

u

it connection 

51mm 

u

p on this end

32

mm

Ceiling grid and
tile (

b

y others)

Ceiling

clos

u

re door

83 mm

192
mm

51

mm

51

mm

198 mm
192 mm

3 mm

192
mm

Mo

u

nting 

b

rackets

S

u

pport rods 

b

y others

Incl. mtg. 

b

rackets

S

u

rro

u

nding 

ceiling

103

mm

www.draperinc.com

(765) 987-7999

MC1

See separate Serial Communication-
RS232 Instruction sheet for enabling 
RS232 with the MC1.

Low Voltage and Remote Control

Wiring Diagrams

Please Note: Do not wire motors in parallel.

Neutral

L1

220v, 
50 Hz.

Dashed wiring 
by installer

Control
switch

Single Station Control

CE Approved

Junction box at 
left end of screen

Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)

Dashed wiring 
by installer

Neutral

Hot

Multiple Station Control

Not CE Approved

Cap off with wire
nut & tape

Red

Red

Red

Blue

Blue

Blue

Black

Black

220v, 50 Hz.

Black

Junction box at 
left end of screen

Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)

Green/Yellow (Motor Ground)

Green/Yellow (Motor Ground)

3 Button Wall Switch  
DOWN - Black 
COM - White 
UP - Red 

White or Blue-Common to screen & 110/220V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 110/220V AC-Hot
Black-to 110/220V AC-Hot

Green(Ground)

Eye Port

 for IR Eye, RF Receiver or LED 

Wall Switch. For more than one of  
these, a splitter is required. 

Aux Port 

for connecting additional LVC-III  

modules (up to six total can be linked- 
connect from Aux to Eye). 

 

Dashed wiring by electrician 

Low voltage wiring by others 

White/Blue (Common)
Red 110/Black 220 (Up)
Black 110/Brown 220 (Down)

Location of key 
operated on-off  
switch if furnished 

To

110/220V

Line

Internal Screen Wiring 
 

STOP 

Control  
Switches 
24v DC 

STOP 

Green 110V/
Green/Yellow 220V
(Motor Ground)

RS232 Data FR

OM Control System 

RS232 Data 

T

O

 Control System 

Signal Ground & Man

ual Switch Common 

Man

ual Switch Do

wn 

Man

ual Switch Up 

White or Blue-Common

Red-to Screen (directional)

Blac

k-to Screen (directional)

Bro

wn-Hot to A

C

Green/Y

ello

w

-Ground

Fuse 

Program LED 

Ey

e P

o

rt

 f

or IR Ey

e

. F

or RF Receiv

er or LED 

W

a

ll Switch, a Splitter and a P

o

w

er Supply 

is required.

 Plug RF Receiv

er or LED 

W

a

ll  

Switch and P

o

w

er Supply into splitter

, then  

run cab

le from Splitter to MC1 Ey

e P

o

rt

Lo

V

oltage 

Wir

ing b

y others 

A

C

 Wir

ing b

y electr

ician 

MC1 

Location of k

ey 

oper

ated on-off  

sw

itch if fur

nished 

To

 A

C

 Line 

White/Blue (Common)

Red 110/Blac

k 220 (Up)

Blac

k 110/Bro

wn 220 (Do

wn)

Inter

nal 

S

creen Wir

ing 

 

Green 110V/

Green/Y

ello

w 220V

(Motor Ground)

Отзывы: