Draper 220V Envoy Скачать руководство пользователя страница 1

Installation/Operating Instructions

220V Envoy Electric Projection Screen by Draper 

Copyright © 2010 Draper Inc. 

Form Envoy220v_Inst10 

Printed in U.S.A.

Operation

When screen is fi rst operated, be cautious! If automatic trap door does not 
drop open im me di ate ly when switch is fl ipped “down”, re turn switch to “off ” 
and free trap door and/or recheck elec tri cal con nec tions before proceeding. 
Cycle unit down and up several times to confi rm sat is fac to ry operation.

220V Single Station Control—

3-position up-off-down switch per mits op er a-

 tion to be stopped at any point. Factory adjusted limit switch es au to mat i cal ly 
stop screen when fully down or fully up.

220V Multiple Station Control 

(Not CE approved)—Switches are similar 

in ap pear ance to 220V Single Station Control. Screen stops when switch 
is re leased and may be re start ed in either direction. Factory adjusted limit 
switches stop screen automatically when fully up or fully down.

24V Control—

Three-button up-stop-down switch es stop at any point de sired, 

operate in any sequence. Factory adjusted limit switches au to mat i cal ly stop 
screen when fully up or fully down. Installer should incorporate an all-pole 
disconnect in the fi xed wiring.

Key Operated Switching 

(Not CE approved)

Two kinds of key-operated 

switches are op tion al ly available with this unit. 

 The key-op er at ed power 

sup ply switch controls power to the screen and switches. When it is “off ”, 
the switches will not operate screen. Key may be re moved from the switch in 
either “on” or “off” position. 

 A three-po si tion key switch per mits the screen 

to be operated directly by key. In this case, the screen’s operator must always 
have a key.

RS232/Ethernet—

Serial communication and network communication 

optionally available with wall switches, RF or IR remote.

Adjustments 

Screen has been factory set and should not nor mal ly require further ad just-
 ment. However, if you desire to change the “up” and “down” stop ping positions, 
proceed as follows:

CAUTION:

 Be sure all switches are in “off ” position before ad just ing limit 

switches. Always be pre pared to shut screen off man u al ly when new ad just-
 ment is being tested. Screen may be se vere ly dam aged if viewing surface is 
al lowed to run too far up or too far down.

Adjusting “fully up” position —

 “Up” limit switch, located im me di ate ly 

above left end of automatic trap door, is tripped as door closes. If door does 
not close fully, limit switch should be raised slightly. If door closes too tightly, 
switch should be lowered slightly.
Remove steel plate attached to threaded neck of “up” limit switch by removing 
hex nut securing it. Removing plate exposes three Phillips head ma chine 
screws which hold limit switch bracket in place. Turn ing these screws clock-
wise will raise limit switch; turning them coun ter clock wise will lower it.
Raise switch only in quarter-turn increments. When operating prop er ly auto-
matic trap door should close gently and rest against but not press on rubber 
bumpers above it. Adjusting automatic door so that it closes too tightly will 
damage screen.

Adjusting “fully down” position —

 “Down” stopping position may be ad-

justed by turning the white limit switch adjustment socket. The white socket is 
located on the left end of screen roller and is accessible to a screw driv er/Allen 
wrench (4mm or 

5

/

32

") when automatic trap door is open. Access is easier 

when bottom board is also open. (Do not adjust the yellow socket which is 
next to and in back of the white socket). Turning the white socket coun ter-
 clock wise will allow the viewing surface to run farther down. Turning it clock-
 wise will shorten the viewing surface, causing it to stop in a less extended 
position. At no time should viewing surface be unrolled enough to expose any 
part of screen roller.

 

 

 

®

If you encounter any diffi culties installing or ser vic ing your Envoy screen, call your 
dealer or Draper, Inc. Spiceland, Indiana, USA, 765/987-7999 or fax 765/987-1689.

Caution

  Read instructions through completely before proceeding.

  Follow instructions carefully. Installation con trary to instructions invali-

 dates 

warranty.

  Do not lift case in center. Lift the ends simultaneously to avoid damage 

 

to case and surface.

  Entire bottom of screen case should be un ob struct ed to permit prop er 

 

operation of automatic trap door, and access to bottom panel for mak ing 

 

electrical connections or servicing.

  Screen should be installed level (using a carpenter’s level).

  Nothing should be fastened to screen dowel, viewing surface or 

 auto 

matic trap door.

  Operating switch(es) packed separately in screen carton. Do not dis card 

 

with packing material.

  Screen operates on 220V AC, 50 Hz., 1 ph. current.

 

These Installation/Operating Instructions are available in the offi cial 

lan guage of the country where you purchase the product. Please contact your 
distributor to request a copy.
 

Vous pourriez demander les instructions d’installation et d’opération 

tra dui ses dans la langue offi cielle du pays ou vous achetez le produit. Veuillez 
de man der à votre distributeur.
 

Die Gebrauchsanweisung für Installation und Konstruktion sind in der 

offi ziellen Sprache des Landes, indem Sie das Produkt gekauft haben, 
vorhanden. Fragen Sie die jeweilige Verkaufs-Abteilung.

Hanging Screen 

General:

When locating viewing surface and checking clear ance for screen’s op er a tion, 
remember surface is centered in case. Screen is normally recessed above 
ceil ing and may be installed in a varie ty of ways. See typical in stal la tion 
detailed on back of this sheet. Re gard less of mounting method used, the 
following points apply:

  Screen should be lifted into position 

only by the mounting brackets. 

 

Keep case level by lifting both ends simultaneously to prevent 

 

surface damage. Never attempt to lift screen along its length.

  Screen should be positively and securely sup port ed so that vibration or

 

even abusive pulling on viewing surface will not weaken in stal la tion.

  Installer must insure that fasteners used are of adequate strength and 

 

suitable for the mounting surface chosen.

  Entire bottom of case must be readily accessible after installation is 

 complete.

  Hinge on bottom board and particularly hinge on automatic trap door of 

 

screen must be per mit ted to operate freely. Front and back of case must 

 

be straight—not forced to warp or bow. Hinges must be free from mas tic 

 

or paint buildup, and doors must be un ob struct ed by ceiling tiles.

  Do not use screen case to support adjacent sections of ceiling.

  If trim pieces must be attached to case, do not permit screws to pro trude 

 

through 19 mm (¾") wall of case. Do not attach trim with nails.

  If case is painted, slots around doors should be shielded to protect 

 

viewing surface from paint splatters or overspray.

  Do not seal unit in ceiling until electrical connections have been made 

 

and screen has been operated successfully.

Electrical Connections

Screen operates on 220V AC, 50 Hz., 1 ph. current.
Junction box is located just above bottom board near left end of screen. 
Bot tom board is held closed with fl athead screws and may be opened with a 
Phillips screwdriver/Allen wrench (4mm or 

5

/

32

"). (Automatic trap door is held 

shut by viewing surface and must not be forced open.) Junc tion box con tains 
brown, black and blue pigtail leads and green internal ground wire, per wiring 
di a gram on reverse.

NOTE

: Screen has been thoroughly inspected and tested at factory and 

found to be operating properly prior to shipment.

Screen is shipped with internal wiring complete and control switch(es) fully 
boxed. Wire connecting screen to switch(es) and switch(es) to power supply 
should be furnished by installer. Connections should be made in accordance 
with attached wiring diagram, and wiring should comply with National and 
local electrical codes.

A

LL

 

OPERATING

 

SWITCHES

 

SHOULD

 

BE

 “

OFF

” 

BEFORE

 

POWER

 

IS

 

CON

 

NECT

 

ED

.