220V Access by Draper
page 3 of 4
www.draperinc.com
(765) 987-7999
Mount ing
hard ware
supplied by
others
Case Dimensions
120mm
54mm
30mm
Engagement
b
racket (one on each end
of the
b
ottom access panel) clicks into
place
w
ith the
b
all detent on each endcap
22.9
cm
20.3 cm
17.8
cm
16.8
cm
L
Access L
Series E 17.8 cm
Series V Varies
Mounting brackets slide
left and right as needed.
Series E or M
Series V
2.6
cm
2.3
cm
2.3
cm
5.4
slot
*These wiring diagrams are for Access screens with motor on audience
left (standard), and fabric unrolling from the back of the roller (standard).
Limit Adjustments (Built-in Low Voltage Motors)
Please note: When ordering a motor with built-in Low Voltage Control-
ler, if the case ships separate from the "guts," the case includes the 25'
cable and special low voltage switch.
①
Connect the ILT switch to the
motor via the terminal blocks,
or via the modular port using
four conductor modular cable.
When using modular cable,
the cable connectors MUST
NOT be crimped in reverse, as
with standard telephone
cable. (For Dry Contacts Wir-
ing Diagram, see page 4.)
②
Set the slide switch to the
lower position. Press and hold
the DOWN button on the
switch to move the viewing
surface to the desired lower
limit. If the screen moves in
the opposite direction, release
the DOWN button and press and hold
down the STOP button for four seconds.
This will reverse the operation of the UP
and DOWN switches.
③
Move slider switch into center position.
Wait a couple of seconds.
Please Note: If you move the slider switch from down to up in one mo-
tion it sets the two limits in the same postion.
④
Set the slide switch to the higher position. Move the viewing surface to the
desired upper limit by pressing and holding the UP button on the wall
switch.
⑤
Return the slide switch to the center position to return to normal operation.
⑥
To set the viewing surface to an alternate format position, move the viewing
surface to the desired position and press the STOP button. Press and hold
the STOP button for at least three seconds to record the position.
Please
Note:
Pressing and releasing the UP button on the switch will move
the screen to its upper limit. Pressing and releasing the DOWN button will
move the screen to its lower limit.
While the motor is in motion, pressing the STOP button for less than two
seconds will stop the viewing surface at its present position.
Once the motor is stopped, pressing the STOP button will move the view-
ing surface to its alternate format position.
Pressing and holding the STOP button, when the motor is at rest or in mo-
tion, for at least three seconds will record a new alternate format position.
Wiring Diagrams—220V Standard and Quiet Motor
Please Note: Do not wire motors in parallel.
Neutral
L1
220v,
50 Hz.
Dashed wiring
by installer
Control
switch
Single Station Control
CE Approved
Junction box at
left end of screen
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Dashed wiring
by installer
Neutral
Hot
Multiple Station Control
Not CE Approved
Cap off with wire
nut & tape
Red
Red
Red
Blue
Blue
Blue
Black
Black
220v, 50 Hz.
Black
Junction box at
left end of screen
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Green/Yellow (Motor Ground)
Green/Yellow (Motor Ground)
Wiring Diagrams—220V Motor
with Built-in Low Voltage Controller
Single Low Voltage Control
Dashed wiring
by electrician
To 220V Line
Multiple Low Voltage Controls
Dashed wiring
by electrician
To 220V Line
Wall Switch,
RF or IR
Receiver,
or integrated
control system
Wall Switches,
RF or IR
Receivers,
or integrated
control systems
Data Cable
Data
Cables
POSITION
FUNCTION
DOWN
UP
CENTER
Set LOWER limit
Set UPPER limit
Normal Operation
STO
P
S
S
T
T
O
O
P
P
To Motor
with
Built-In
Low Voltage
Slide
Switch
Back View
U
p
D
o
w
n
C
o
m
m
o
n
+
5V
DC
To Motor
with
Built-In
Low Voltage