ILT Limit Adjustment Continued from Page 1
➄
To set the viewing surface to an alternate format
position, move the viewing surface to the desired
position and press the STOP button. Press and
hold STOP for at least three seconds to record
the
position.
Please
Note:
Pressing and
releasing the UP button on the
switch will move the screen to its
upper limit. Pressing and releas-
ing the DOWN button will move
the screen to its lower limit.
While the motor is in motion, pressing STOP for
less than two seconds will stop the viewing surface at its present position.
Once the motor is stopped, pressing the STOP button will move the viewing
surface to its alternate format position.
Pressing and holding the STOP button, when the motor is at rest or in motion,
for at least three seconds will record a new
alternate format position.
Targa by Draper
Fabric width + 7"
Viewing
surface
3
1
/
2
"
7
/
8
" dia.
electrical
connection
hole
5
7
/
8
"
2
5
/
16
"
5
1
/
4
"
Case Dimensions
Page 2 of 2
Wall Mounted
Appropriate hard
w
are
pro
v
ided
b
y installer.
Suspended
Appropriate hard
w
are
pro
v
ided
b
y installer.
Types of Installation
Optional Ceiling Opening Trim Kit
(Dims-Side View)
2
1
/
8
"
2
1
/
16
"
4"
6
3
/
4
"
1
1
/
16
"
8
"
7
/
8
" hole for
electrical
connection.
Fasteners for
w
all mo
u
nting
b
y others.
S Hooks for
s
u
spended
installation
b
y others.
Methods of Installation
www.draperinc.com
(765) 987-7999
Single Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring
by electrician
Control
switch
Single gang box by others
Min. 4" x 2
1
/
8
" x 1
7
/
8
" deep
Blue
Black
Red
Location of key
operated on-off
switch if furnished
To 110-120V Line
Multiple Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring
by electrician
Red
Red
Black
Blue
Blue
Cap off with wire
nut and tape
Black
Red
Blue
Black
Single gang box by others
Min. 4" x 2
1
/
8
" x 1
7
/
8
" deep.
3 shown. More or less equally
feasible.
Location of key
operated on-off
switch if furnished
To 110-120V Line
Wiring Diagrams—110-120V Motor and Quiet Motor
Wiring Diagrams—110-120V Motor and Quiet Motor
with Built-in Low Voltage Controller
Single Low Voltage Control
Internal Screen Wiring
White (Neutral)
Black
Green (Ground)
Dashed wiring
by electrician
To 110-120V Line
Multiple Low Voltage Controls
Internal Screen Wiring
White (Neutral)
Black
Green (Ground)
Dashed wiring
by electrician
To 110-120V Line
Wall Switch,
RF or IR
Receiver,
or integrated
control system
Wall Switches,
RF or IR
Receivers,
or integrated
control systems
Data Cable
Data
Cables
6" Extension
Bracket
S
S
T
T
O
O
P
P
To Motor
with
Built-In
Low Voltage
Slide
Switch
Back View
U
p
D
o
w
n
C
o
m
m
o
n
+
5V
DC
To Motor
with
Built-In
Low Voltage
POSITION
FUNCTION
DOWN
UP
CENTER
Set LOWER limit
Set UPPER limit
Normal Operation
STO
P
Please Note: Do not wire motors in parallel.