background image

12

– To turn on the device 
–  To turn off the device, hold the button 

for 5 seconds, (NOTICE! TG pro can 
be turned off via the menu using ”

Turn off!

”,  

if the device is not operated, it will turn off  
automatically in order to save the battery) 

–  To start the main menu – hold the button  

for 2 seconds 

– To delete program functions 

– To confirm program function
– To start measurement 

– To navigate up and down the menu 
– To set the values in the menu 
– To select the grain from the list of species 

–  To clear the average result of the measurements 

of a particular sample 

–  To save the result with the date  

and hour to the memory of the device 

pro

CHAPTER 3 | KEYBOARD FUNCTIONS

Содержание Twist Grain pro

Страница 1: ...Drami skiTwistGrainpro Grain moisture meter with sample compressor INSTRUCTION MANUAL www draminski com ISO 9001 EN...

Страница 2: ...NOTES FOR MEASUREMENTS 17 CHAPTER 6 HUMIDITY MEASUREMENTS 21 CHAPTER 7 EXTERNAL TEMPERATURE PROBE MEASUREMENTS 25 CHAPTER 8 LIST OF AVAILABLE SPECIES AND HOW TO ADD NEW SPECIES 29 CHAPTER 9 UPDATE VIA...

Страница 3: ...2...

Страница 4: ...3 EN INTRODUCTION...

Страница 5: ...ly reserves the right to introduce changes and improve ments to the design and the software DRAMINSKI S A also reserves the right to introduce changes to the present instruction manual Before using th...

Страница 6: ...5 EN EQUIPMENT CHAPTER 1...

Страница 7: ...easuring chamber with inserted 3V battery type CR 2032 3 Transport case 4 Carrying strap attached to the case which enables hanging the device 5 USB cable used to communicate with the computer 6 Instr...

Страница 8: ...7 EN CONSTRUCTION OF THE DEVICE CHAPTER 2...

Страница 9: ...BS body 4 LCD LED backlit graphic display 5 Four button membrane keyboard 6 Mini USB slot with a rubber protector 7 Chamber for 4 batteries 1 5V type LR6 AA 1 The cap s body is made with addition of f...

Страница 10: ...9 EN CHAPTER 2 EXTERNAL CONSTRUCTION APPROXIMATE DIMENSIONS 7 cm 7 5 cm 16 5 cm...

Страница 11: ...10 CHAPTER 2 EXTERNAL CONSTRUCTION...

Страница 12: ...11 EN KEYBOARD FUNCTIONS CHAPTER 3...

Страница 13: ...battery To start the main menu hold the button for 2 seconds To delete program functions To confirm program function To start measurement To navigate up and down the menu To set the values in the menu...

Страница 14: ...13 EN HOW TO START THE DEVICE CHAPTER 4...

Страница 15: ...that to satisfy the needs of the most demanding customers Addition ally people who use the advanced mode can download special software from our site www draminski com to communicate with the computer...

Страница 16: ...in stand by mode for a few minutes it will be turned off automatically this time can be set in the menu see chapter MAIN MENU The device will signal this by turning on the display and there appears a...

Страница 17: ...causes that you go back to the list of available species function Clr clears the average result function Mem safes the result in the internal memory function Start launches another measurement pro TG...

Страница 18: ...17 EN NOTES FOR MEASUREMENTS CHAPTER 5...

Страница 19: ...ents residual grain may penetrate to the screw of the cap In order to make twisting the cap easier you should regularly clean the screw do not use any sharp tools for that purpose Please remember to c...

Страница 20: ...be a name it is important because it helps the results to be properly catalogued If you notice some important deviations in the results for a certain species which increase or decrease the value in th...

Страница 21: ...20 CHAPTER 5 NOTES FOR MEASUREMENTS...

Страница 22: ...21 EN HUMIDITY MEASUREMENTS CHAPTER 6...

Страница 23: ...d fix the tightening cap on the thread of the measuring chamber until you hear a sound made by the cap This sound means that the force of the tightening is correct However in order to save the battery...

Страница 24: ...samples with different and increased humidity h the final result of the moisture of the given sample is the average of let s say last three measurements The TG pro calculates it automatically and show...

Страница 25: ...art j when you finish the measurements in order to save the source of power supply it is necessary to switch off the device holding the button for 5 seconds or with the help of the option Turn off ava...

Страница 26: ...25 EN EXTERNAL TEMPERATURE PROBE MEASUREMENTS CHAPTER 7...

Страница 27: ...the results changing the temperature scale 0 C 0 F In order to learn about all the functions please familiarise yourself with Chapter 11 MAIN MENU 1 In order to use the temperature probe change to adv...

Страница 28: ...1 01 2018 11 00 21 70C PROBE NO 1 Special software for data transition is available at the site www draminski com bookmark Products Moisture meters Draminski TwistGrain pro CHAPTER 7 EXTERNAL TEMPERAT...

Страница 29: ...28 CHAPTER 7 EXTERNAL TEMPERATURE PROBE MEASUREMENTS...

Страница 30: ...29 EN LIST OF AVAILABLE SPECIES AND HOW TO ADD NEW SPECIES CHAPTER 8...

Страница 31: ...n activate additional species by entering their code in the main menu using the option Add species see CHAPTER MAIN MENU In order to obtain this special code activating the species which you need in y...

Страница 32: ...31 EN UPDATE VIA USB CHAPTER 9...

Страница 33: ...availability at www draminski com in the bookmark Products Moisture meters Draminski TwistGrain pro You will also find there step by step instructions how to process the update Our software developers...

Страница 34: ...33 EN MODIFICATION OF HUMIDITY RESULTS CHAPTER10...

Страница 35: ...Please remember to compare the measurements only to laboratory drying and weighing method but not to other moisture meters because they may mislead you The Draminski TG pro moisture meter enables intr...

Страница 36: ...35 EN A detailed description how to carry out modification of humidity results and how to reset default settings you will find in Chapter MAIN MENU CHAPTER 10 MODIFICATION OF HUMIDITY RESULTS...

Страница 37: ...36 CHAPTER 10 MODIFICATION OF HUMIDITY RESULTS...

Страница 38: ...37 EN MAIN MENU CHAPTER11...

Страница 39: ...t Thanks to this function the user can turn off the device quickly without the necessity of holding the button for 5 seconds 2 Species list In order to return from the MAIN MENU to the list of species...

Страница 40: ...ort enter the Main menu then navigate or and choose the option Temper ature measurement and confirm with button NOTICE In order to save the results to the memory of the device add the probe in the set...

Страница 41: ...t a proper value with the help of or and confirm with the button for example TG pro 21 01 2018 Display Backlight intensity Backlight off time LCD contrast TG pro 21 01 2018 0 100 30 Backlight intensit...

Страница 42: ...opriate value with the help of or and confirm with for example TG pro 21 01 2018 Settings Language Display Power auto off Number of averages TG pro 21 01 2018 Power auto off 1 30 3 min 5 4 Number of a...

Страница 43: ...firm with the button for example 21 01 2018 TG pro Settings Display Power auto off Number of averages Temperature scale TG pro Temperature scale Celsius Fahrenheit 21 01 2018 5 6 Date time The TG pro...

Страница 44: ...e TG pro 21 01 2018 Date time Set date Set time Date notation metric Time notation 24H TG pro 21 01 2018 Date time Set date Set time Date notation U S Time notation 24H 5 6 d Time notation in order to...

Страница 45: ...H I J K L M NO PQR S T U VW X Y Z 5 7 b Rename in order to rename previously saved probe enter the Main menu Settings Tempera ture probes Rename select the name you would like to change with the arrow...

Страница 46: ...1 2018 Memory Save result Delete humidity results Delete temperature res Available memory TG pro 21 01 2018 Memory Save average Delete humidity results Delete temperature res Available memory 5 8 b De...

Страница 47: ...ON OF HUMIDITY RESULTS In order to insert modifications for the species enter the Main menu Result modification with the help of or select the species you would like to modify then select the value by...

Страница 48: ...der to enter the special code select proper signs with the help of or and confirm with in order to delete the sign use the symbol and confirm with When you have entered the code a message appears Acce...

Страница 49: ...t details of the Draminski S A company TG pro 21 01 2018 Main menu Settings Result modification Add species About www draminski com Twist Grain pro Firmware v 1 4C K 0 10 SN T G000010 Drami ski S A ul...

Страница 50: ...49 EN CHANGE OF BATTERIES CHAPTER12...

Страница 51: ...owered by four 1 5 V type LR6 AA batteries In order to change the batteries open the cover of the battery compartment with the help of the ribbon tip place the ribbon across inside of the battery comp...

Страница 52: ...ound becomes weak or disappears it is necessary to change the battery To change the battery you should unscrew two screws which are in the cap lift the lid and delicately lever the battery from the ba...

Страница 53: ...52 CHAPTER 12 CHANGE OF BATTERIES...

Страница 54: ...53 EN FINAL NOTES CHAPTER13...

Страница 55: ...rder to limit the risk of dam age of the device due to leakage of the electrolyte It is recommended to use batteries of recognised manufacturers If any problems appear with the device or when inter pr...

Страница 56: ...55 EN TECHNICAL DATA CHAPTER14...

Страница 57: ...54hourswhenbacklightissetto30 Lowbatteryindicator graphic Measurementresolution humidity 0 1 temperature 0 1 C F Humiditymeasurementaccuracy 0 5 fornormalizedgrain 1 intherangeupto10 ofhumidity 1 5 i...

Страница 58: ...memorystatus previewofbatterystatus temperaturemeasurementwithanexternalprobe changeofoperatingmode basic advanced modificationofhumidityresults addingnewspeciesusingspecialcodes calculationoftheavera...

Страница 59: ...58...

Страница 60: ...www draminski com DRAMI SKI S A Owocowa 17 10 860 Olsztyn Poland phone 48 89 527 11 30 e mail agri draminski com Instr TGpro1217PL1 0...

Отзывы: