DRAKE DTS86 Скачать руководство пользователя страница 7

7

[1] Power-save mode: After approximately 3 minutes of no interaction, the unit will enter into its power-save

mode by turning off all front-panel LeDs and displays. the dot of the 2-digit LeD will remain lit to indicate unit

is powered and operating normally. Pressing any button will bring the unit out of power-save mode and current

channel and modes will be displayed.
[2] Unit Reset: Holding the RF Mode and Baud Rate buttons simultaneously for 5 seconds will reset the unit.

All three digits of the unit will display a countdown from 5 to 0 and then reset. After reset, the unit will return to its

last programmed state. A reset is required after a firmware or software update.
[3] Alerts: the DtS860 has 2 alerts to indicate a non-typical condition or error in operation. the 1-digit LeD will

display ‘e’. the 2-digit LeD will display the condition number as described below.
01 E – internal communication error between microcontroller and decoder. Perform a unit Reset or disconnect/

reconnect the power to correct this.
02 E – No signal error. tV/monitor screen will display ‘No signal’. Verify that incoming Rf is connected and 

desired/undesired channels are at recommended levels. Press the SNR button and confirm that signal-to-noise 

ratio is greater than 20 for 8VSB, 25 for QAm 64, 30 for QAm 256.  Also confirm that the correct frequency plan, 

modulation and baud rate have been set. 

Operation

Содержание DTS86

Страница 1: ...Instruction Manual DTS860 Digital Transport Stream is a registered trademark of the R L Drake Holdings LLC Copyright 2013 R L Drake Holdings LLC P N 651230000A Rev 20200728 1002575...

Страница 2: ...IRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE DO NOT OPEN THE CABINET REFER SERVICING TO QUALIFIED PERSONNEL ONLY CAUTION TO PREVENT ELECTRIC SHOCK DO NOT USE THIS POLARIZED PLU...

Страница 3: ...lectrode 14 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords a...

Страница 4: ...rades Dimensions 1 0 x 7 78 x 3 5 inches 25 x 198 x 89 mm Power Dissipation 5 W max per module 5 VDC 370 mA 12 VDC 200 mA Weight 0 8 lbs 0 36 kg Operating Temperature 32 to 122 F 0 to 50 C Storage Tem...

Страница 5: ...d System Information Protocol feature It may also be referred to as the tune to NAB or as a virtual channel Digital TV s along with digital demodulators such as Drake s DAV860 use the virtual channel...

Страница 6: ...0 35 3 100 000 64 6 10 000 03 0 1 000 52 5 100 31 3 10 70 7 1 When the baud rate digit with multiplier is displayed pushing either the UP or DN buttons will change the digit in sequence 0 1 2 3 4 5 6...

Страница 7: ...to its last programmed state A reset is required after a firmware or software update 3 Alerts The DTS860 has 2 alerts to indicate a non typical condition or error in operation The 1 digit LED will di...

Страница 8: ...8 Notes...

Страница 9: ...9 Notes...

Страница 10: ...the same in its original container or equivalent fully insured and shipping charges prepaid Correct maintenance repair and use are important to obtain proper performance from this product Therefore ca...

Страница 11: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 12: ...R L Drake Holdings LLC Sales and Service 800 523 6049 Fax 732 679 4353 Web Site www rldrake com...

Отзывы: