DRAKE DSE24 Скачать руководство пользователя страница 12

12

OPERATING INSTRUCTIONS – FROM THE FRONT-

PANEL
1) Connect video and audio inputs to the appropriate rear

panel input connections.
2) Connect the output connector (R1 on page 8) to the

program distribution system as desired.
3) Plug the external power supply into the DC PoweR jack

(R2 on page 8) and plug the external power supply into AC 

power. Allow approximately 10 seconds for bootup. Note that 

the DSe24 will be in the oN state whenever power is applied.
4) from the front panel, use the uP, DowN, Left, RiGHt,

eNteR and SeLeCt buttons to choose among DSe24 

settings. use the eNteR button to enter program mode and 

to save settings in memory. use Left and RiGHt arrow 

buttons to select a parameter and then use the uP or DowN 

arrows to change its value. Parameter values can only be 

changed when the unit is in the program mode as indicated 

by slow flashing of the bottom line of the front panel display.
5) enter program mode by pressing the eNteR key and hold

for 2 to 3 seconds.
6) Repeatedly press the left or right arrows (on either side of

the enter button) until the display shows the parameter you 

wish to program. Press uP or DowN arrows to select which 

value you choose for that particular parameter. Proceed in 

this manner until all parameters have been programmed to 

the desired values. when you reach the CHANNeL NAme 

parameter, use the Left and RiGHt SeLeCt buttons to 

position the flashing cursor to the desired position, and 

use the uP and DowN arrows to select the alphanumeric 

character for that particular position.
7) Repeatedly press the Left or RiGHt arrows as required

until the ViDeo iNPut screen is obtained. then use the uP 

and DowN arrows to select the correct video input.
8) using the same technique, set the desired values

for the ReSoLutioN, eNCoDe bitRAte, PRofiLe, i-P 

iNteRVAL, GoP fRAmeS, CLoSeD GoP, bRiGHtNeSS, 

CoNtRASt, SAtuRAtioN, Hue, HoRiZ SHift, HoRiZ 

wiDtH, AuDio iNPut and AuDio GAiN screens.
9) Press RiGHt arrow again and observe the qAm
moDe screen. use up or down arrows to select qAm mode. 

for example, qAm-256b would select 256 qAm with annex 

b feC (DigiCipher feC).
10) Press RiGHt arrow again and observe iNteRLeAVeR.

Select i128,J1 unless you have a special requirement. 
11) Press RiGHt arrow again and move to the outPut

foRmAt. Choose NoRmAL. for testing/level setup, 

temporarily choose Cw to produce a Cw carrier in the center 

of the channel. to temporarily turn off the Rf output without 

removing power from the DSe24, select StANDby.
12) Press the RiGHt arrow button again and observe

outPut CHANmAP. Select the desired plan, usually CAtV.
13) Press RiGHt arrow and observe outPut CHANNeL.

Select desired channel. the Rf channel number being set 

will be used as the major channel number in the output 

stream.
14 Press RiGHt arrow button and observe outPut LeVeL. 

Choose desired Rf out level.
15) Press RiGHt arrow again. this should produce the qAm

mGt/VCt eNAbLe screen. usually select tVCt by using up 

or down arrows.
16) move on to the CHANNeL NAme screen using the

RiGHt arrow button. there are seven cursor positions 

available for naming the channel. use the uP and DowN 

buttons to select the alphanumeric character for each of the 

seven positions and use the SeLeCt arrows to move the 

cursor to the desired character position. Note that this screen 

may not appear depending on the setting of the mGt/V 

eNAbLe window.
17) Press RiGHt arrow and observe mAJoR CHANNeL.

Select desired channel. the Rf channel number being set 

will be used as the major channel number in the output 

stream. Note that this screen may not appear depending on 

the setting of the mGt/V eNAbLe window.
18) Press RiGHt arrow and observe miNoR CHANNeL.

Select desired channel. the Rf channel number being set will 

be used as the minor channel number in the output stream. 

Note that this screen may not appear depending on the setting 

of the mGt/V eNAbLe window.
19) Press eNteR to save all of the previous settings. if any

of the settings need to be changed from the previously set 

values, re-enter program mode and adjust each parameter as 

required.
20) Press eNteR to store any unsaved changes.
21) to set the encoder to typical default settings, press the uP

arrow, DowN arrow, and eNteR buttons all at the same time. 

Hold the three buttons in for several seconds and release.

Operating Instructions (From the Front Panel)

Содержание DSE24

Страница 1: ...Instruction Manual with Closed Captioning is a registered trademark of the R L Drake Holdings LLC Copyright 2013 R L Drake Holdings LLC P N 651228200A Printed in the USA Rev 20130411 1002571 ...

Страница 2: ... basement or near a swimming pool and the like Table of Contents Caution Important Safety Instructions WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE DO NOT OPEN THE CABINET REFER SERVICING TO QUALIFIED PERSONNEL ONLY CAUTION TO PREVENT ELECTRIC SHOCK DO NOT USE THIS POLARIZED PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLET UNLESS THE BLA...

Страница 3: ...ar attention to cords at plugs convenience receptacles and the point where they exit from the product 15 Lightning For added protection for this product during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the antenna or cable system This will prevent damage to the product due to lightning and power line surges 16 ...

Страница 4: ...verage 5 1000 MHz Channel Plans STD HRC IRC Broadcast and T Channels Output Power 45 dBmV Output Level Adjustment Range 15 dB Phase Noise 95 dBc Hz 10 kHz offset Broadband Noise 75 dBc 12 MHz offset 4 MHz bandwidth MER 40 dB equalized Channel Frequency Response 1 dB Carrier Suppression 40 dB I Q Imbalance 1 degree Output Level Accuracy 1 dB Spurious 60 dbc Second Harmonic in the T Channel band 55 ...

Страница 5: ... be rack mounted in just 1RU of height The DSE24 accepts analog high definition or standard definition video input via component VGA or composite inputs Digital video can also be input via a HDMI without HDCP input Audio can be input via imbedded HDMI audio S PDIF optical digital input or analog left and right RCA jacks Video is encoded using MPEG2 encoding Audio is encoded using MPEG1 Layer 2 enc...

Страница 6: ...tting F3 Up and Down Buttons Use the up and down arrow buttons to change the value of a viewed parameter setting The unit must be in the program mode in order for these buttons to become active for changing a parameter setting If the unit is not in the program mode repeatedly pressing the Up button will toggle between the version number of the DSE24 firmware and the video and audio status Pressing...

Страница 7: ...ive when VGA is input on R6 R6 VGA INPUT This VGA type connector provides the means to input VGA video from a computer or other device with VGA output R7 COMPONENT VIDEO These three color coded RCA connectors Cr red Cb blue and Y green provide the means to input component video To input composite video use the green Y connector R8 HDMI CONNECTOR This connector provides the means to input HDMI vide...

Страница 8: ...8 Software Flow Chart ...

Страница 9: ...o move the cursor to the desired location and use the UP and DOWN buttons to scroll through the list of alphanumerics until the desired character appears Note that the SELECT buttons will have no affect in normal mode or in program mode if the selected menu item requires no alphanumeric This section provides additional details regarding the selectable items shown in the program mode on the Softwar...

Страница 10: ...ices are available OUTPUT FORMAT For normal operation select NORMAL For system level set up choose CW to provide a CW carrier at the center frequency of the output channel for use in leveling a system when a QAM power meter is not available To disable all RF output select STANDBY In the CW mode the CW carrier can be measured on a spectrum analyzer without a need to apply a bandwidth correction or ...

Страница 11: ...NEL NAME and USER NAME There are 8 cursor positions available HOST NAME A host name may be entered in this window using the same technique described previously There are 15 cursor positions available MAC ADDRESS This menu item allows the user to view the MAC ADDRESS of the DSE24 This may be useful when debugging network connectivity issues WARNING Do not change If necessary to reenter see the labe...

Страница 12: ...6 QAM with annex B FEC DigiCipher FEC 10 Press RIGHT arrow again and observe INTERLEAVER Select I128 J1 unless you have a special requirement 11 Press RIGHT arrow again and move to the OUTPUT FORMAT Choose NORMAL For testing level setup temporarily choose CW to produce a CW carrier in the center of the channel To temporarily turn off the RF output without removing power from the DSE24 select STAND...

Страница 13: ...at all connections to the DSE24 have been made as described previously With power to the DSE24disconnected connect an Ethernet cable from the Ethernet jack on the back of the DSE24 to the Ethernet connector on your PC or to your network router Then apply power to the DSE24 2 After the DSE24 has booted up scroll to the USER NAME screen using the LEFT or RIGHT arrow buttons and enter program mode by...

Страница 14: ... button causes the display to show the video and audio status but does not toggle USING A PC AS A VIDEO SOURCE When using a PC as your video source please ensure that the resolution is set to one of the following modes 640x480 60Hz 720x480 60Hz 1280x720 60Hz or 1920x1080 30Hz While PC s can generate many other output resolutions the DSE24 will only operate correctly with these video settings If th...

Страница 15: ...15 CATV CHANNEL FREQUENCIES Table 1 CATV ...

Страница 16: ...16 CATV CHANNEL FREQUENCIES ...

Страница 17: ...AKE also provides technical assistance by e mail TechSupport rldrake com or by Telefax 1 937 806 1510 Many of the products that are sent to us for repair are in perfect working order when we receive them For these units there is a standard checkout fee that you will be charged Please perform whatever steps are applicable from the installation sections of the Owner s Manual before calling or writin...

Страница 18: ...ood reason to call before sending a unit in for repair Typically equipment is repaired in five to ten working days after it arrives at R L DRAKE if we have all the facts If we must call you it may take longer R L DRAKE is not responsible for damage caused by lightning nonprofessional alterations acts of God shipping damage poor storage handling etc R L DRAKE will make note of any shipping damage u...

Страница 19: ...re important to obtain proper performance from this product Therefore carefully read the Instruction Manual This warranty does not apply to any defect that R L DRAKE HOLDINGS LLC determines is due to 1 Improper maintenance or repair including the installation of parts or accessories that do not conform to the quality and specifications of the original parts 2 Misuse abuse neglect or improper insta...

Страница 20: ...R L Drake Holdings LLC 710 Pleasant Valley Drive Springboro ohio 45066 uSA Customer Service and Parts Telephone 1 937 746 6990 Telefax 1 937 806 1510 Web Site http www rldrake com ...