[1] Firmware/Software:  following unit power-up or reset, the boot-up routine will begin. first, the 2-digit LeD will 

display the internal microcontroller firmware revision. After a few seconds, all three LeD digits will display the 

internal HD decoder software revision. upon completion of the boot-up routine, a previously configured unit 

will retain and display its last programmed channel, while a new or updated unit will alert a scan requirement.

[2] 8VSB/QAM mode:  Holding the SNR button in for 10 seconds will change modes from off-air 8VSB input to 

CAtV QAm input or vice versa.  When in QAm input mode, the QAm LeD will light.  in 8VSB input mode, the 

QAm LeD will be off.  typically, a new scan will be needed when the input mode has been changed.

[3] Power-save mode:  After approximately 3 minutes of no interaction, the unit will enter into its power-save 

mode by turning off all front-panel LeDs and displays.  the dot of the 2-digit LeD will remain lit to indicate 

unit is powered and operating normally.  Pressing any button will bring the unit out of power-save mode and 

current channel and modes will be displayed.

[4]  Unit Reset:  Holding the PIC and AUD buttons simultaneously for 5 seconds will reset the unit.  All three 

digits of the unit will display a countdown from 5 to 0 and then reset.  After reset, the unit will return to its last 

programmed state.  A reset is required after a firmware or software update.  in this instance, the unit will need 

to be rescanned and picture size and audio mode will need to be set again to restore the unit to operate as 

configured previously.

[5] Alerts: the DAV860 has 7 alerts to indicate a non-typical condition or error in operation.  the 1-digit LeD will 

display ‘e’.  the 2-digit LeD will display the condition number ‘01’ thru ‘07’, as described below.

01 E – internal communication error between microcontroller and decoder. Perform a unit Reset or disconnect/

reconnect the power to correct this.  

02 E – No signal error. tV/monitor screen will display ‘No signal’. Verify that incoming Rf is connected and desired/

undesired channels are at recommended levels. Press the SNR button and confirm that signal-to-noise ratio is greater 

than 20 for 8VSB, 25 for QAm 64, 30 for QAm 256. 

03 E – Channel database error. in 8VSB mode, tV/monitor screen will display ‘No terrestrial channels found, Please 

scan to add channels’.  in QAm mode, tV/monitor screen will display ‘No cable channels found, Please scan to add 

channels’. Perform a scan to correct this.

04 E – No program alert.  indicates the channel currently has no program. tV/monitor screen will display ‘No program’.

05 E – Audio only alert.  indicates the channel is an audio only program. tV/monitor screen will display ‘Audio only’.

06 E – Video only alert.  indicates the channel has video only program.

07 E – Scrambled alert.  indicates the channel has a scrambled program. 

 

CAUTION:

Do Not eXCeeD tHe mAXimum CuRReNt RAtiNG of tHe PSm121 PoWeR SuPPLy iN 

tHe Rmm12 CHASSiS.  tHe PSm121 CAN PoWeR A mAXimum of (8) DAV860’S. uSe tHe 

PSm125 PoWeR SuPPLy if ALL 12 CHASSiS moDuLe PoSitioNS ARe to Be uSeD.

Operation

Содержание DAV860

Страница 1: ...Instruction Manual DAV860 Digital Decoder is a registered trademark of the R L Drake Holdings LLC Copyright 2012 R L Drake Holdings LLC P N 651229900A Printed in China Rev 201201026 1002574 ...

Страница 2: ...FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE DO NOT OPEN THE CABINET REFER SERVICING TO QUALIFIED PERSONNEL ONLY CAUTION TO PREVENT ELECTRIC SHOCK DO NOT USE THIS POLARIZED PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE ATTENTION POUR PREVENIR LES CHOCS ELECTRIQUES NE PAS UTILISER CETTE FICHE POLARIS...

Страница 3: ...ar attention to cords at plugs convenience receptacles and the point where they exit from the product 15 Lightning For added protection for this product during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the antenna or cable system This will prevent damage to the product due to lightning and power line surges 16 ...

Страница 4: ... 8 lbs 0 36 kg Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 13 to 158 F 25 to 70 C Operating Humidity 0 to 95 RH 35 C Max non condensing Storage Humidity 0 to 95 RH 35 C Max non condensing Connector F Female Standards 8VSB QAM ATSC Digital Television Standard A 53E ITU T J 83 64 and 256 QAM 8VSB Mode Tuning Range Symbol Rate Bandwidth UHF NTSC Ch 14 78 VHF NTSC Ch 2 13 10 762 Ms...

Страница 5: ...play Used to identify program major channel The decimal dot will always be lit For channels above 99 the 100 LED will blink and the last two digits will be displayed For example channel 102 will have 100 LED blink and 02 on the display 4 One Digit Channel Display Used to identify program s minor channel Range is 1 9 A 10 B 11 C 12 D 13 E 14 F 15 For minor channel 16 or higher the display will read...

Страница 6: ... indicating channel numbers If 5 seconds pass without pressing the ENT button the display will return to its last programmed state and stop blinking Picture Size 2 digit LED 1 digit LED AFD AF d Center Cut Pl C Letterbox Pl L Full Pl F Zoom1 Pl 1 Zoom2 Pl 2 AFD Active Format Description uses AFD data and will automatically switch between Letterbox and Center Cut as defined by broadcaster In the ab...

Страница 7: ...Stereo outputs left and right stereo audio program CC is off AU 3 SAP outputs only the mono secondary audio program on both left and right ports CC is off AU 4 Mono with Closed Captioning outputs same mono audio program on both left and right ports CC is on AU 5 Stereo with Closed Captioning outputs left and right stereo audio program CC is on AU 6 SAP with Closed Captioning outputs only the mono ...

Страница 8: ...ce the unit will need to be rescanned and picture size and audio mode will need to be set again to restore the unit to operate as configured previously 5 Alerts The DAV860 has 7 alerts to indicate a non typical condition or error in operation The 1 digit LED will display E The 2 digit LED will display the condition number 01 thru 07 as described below 01 E Internal communication error between micr...

Страница 9: ... are important to obtain proper performance from this product Therefore carefully read the Instruction Manual This warranty does not apply to any defect that R L DRAKE HOLDINGS LLC determines is due to 1 Improper maintenance or repair including the installation of parts or accessories that do not conform to the quality and specifications of the original parts 2 Misuse abuse neglect or improper ins...

Страница 10: ...10 Notes ...

Страница 11: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 12: ...R L Drake Holdings LLC 9900 Springboro Pike Miamisburg Ohio 45342 USA Customer Service and Parts Telephone 1 937 746 6990 Telefax 1 937 806 1576 Web Site http www rldrake com ...

Отзывы: