DRAKE DAR8642 Скачать руководство пользователя страница 1

®

Rack Mount Distribution Amplifiers, with Power Doubled Hybrid Output          1

DESCRIPTION

The R.L. DRAKE models DAR8642, DAR8633, DAR8618,

DAR7542, and DAR7533,  are broadband distribution

amplifiers designed for indoor headend use in both

residential and commercial buildings where RF signal

distribution in the frequency range of 47 to 860 MHz is

required.  Each model, except the DAR8618, incorporates a

push-pull hybrid input preamp and a power doubled hybrid

output amplifier to provide a very low distortion signal for

launch amp applications in the output of an SMATV or CATV

headend.  The Gain and Slope controls operate between the 

figure over a wide range of gain and slope settings.

Only the DAR8618 has a power doubled output hybrid with

no input preamp. 

Input and output test connectors are provided for convenient

monitoring of the signal path.  The amplifier circuitry is

designed for maximum stability, low distortion, low noise

figure, and is protected in a rugged aluminum housing.

 

The

 unit operates from a nominal 100-240 VAC, 50/60 Hz input.

E

P

O

L

S

N

I

A

G

DAR DISTRIBUTION AMPLIFIER

INPUT 

MONITOR

-20 dB

POWER

OUTPUT

MONITOR

-20 dB

MIN.           MAX.

MIN.           FLAT

F1 - POWER LED

This indicator illuminates when power is supplied to the unit.

F2 - INPUT MONITOR

This connector may be used to monitor input to the DAR.

The levels will be 20 dB below the input levels at R3.

F3 - GAIN

Adjusts the amplifier interstage attenuator.

F4 - SLOPE

Adjusts the slope of the output signal.

F5 - OUTPUT MONITOR

This connector may be used to monitor the output of the

DAR.  Levels will be 20 dB below those present at R2.

R2 must be terminated in 75 Ohms for an accurate reading.

preamp hybrid and the output hybrid  to maintain a low noise

F2 

         F3         F4                                                  F5                     F1

Содержание DAR8642

Страница 1: ...ut and output test connectors are provided for convenient monitoring of the signal path The amplifier circuitry is designed for maximum stability low distortion low noise figure and is protected in a rugged aluminum housing The unit operates from a nominal 100 240 VAC 50 60 Hz input E P O L S N I A G DAR DISTRIBUTION AMPLIFIER INPUT MONITOR 20 dB POWER OUTPUT MONITOR 20 dB MIN MAX MIN FLAT F1 POWE...

Страница 2: ...ution and is the amplified output of channels that are input to port R3 from 54 MHz and higher R3 RF INPUT This connector accepts the RF input from a headend combiner output 54 MHz and higher R1 AC LINE CORD Connect this line cord to a 100 240V 50 60 Hz AC power source R1 R3 R2 ...

Страница 3: ...ot higher than the high end of the band Since there can be a slight interaction between the slope and gain settings it is advised to repeat this step a few times to ensure the desired levels are attained NOTE The 20 dB input and output test ports can be used to monitor input and output levels These are only accurate when the load is connected to the amplifier output and power is on A WORD CONCERNI...

Страница 4: ...ginal proof of purchase to establish the start of the warranty period 2 Notify R L DRAKE HOLDINGS LLC or the nearest authorized service facility as soon as possible after discovery of a possible defect of a the model and serial number b the identity of the seller and the approximate date of purchase and c A detailed description of the problem including details on the electrical connection to assoc...