DRAKE DAD860 Скачать руководство пользователя страница 8

8     DAD860 Setup and Programming

INTRODUCTION

The programming of each DAD860(A) in an RMM12
rack mounting frame is done with the DAD860
Controller, or by a PC running Drake ‘DAD860 Remote
Control Software’. The following discussion will
describe the use of the DAD860 Controller.  Use of
‘DAD860 Remote Control Software’ will be covered in
documentation included with the software.

NOTE: The information presented on pages 8, 9, and
10 applies to the DAD860 and DAD860A even though
the references will only mention DAD860.

The UNIT button on the DAD860 Controller is used to
select the unit to be programmed.  The actual pro-
gramming is done via the UP, DOWN, LEFT, RIGHT
and ENTER buttons.

The chart below shows each of the menus that are
available for parameter value setup and/or viewing
for the DAD860 being programmed.  Pressing the
LEFT or RIGHT arrow buttons will navigate through
these menus.  You may do this without danger of
disturbing any of the current settings when not in
program mode.

As you navigate through the menus the parameter
name is listed on the top line of the display and the
current value is shown on the bottom line.  For
setup purposes, it is best to progress clockwise
through the chart (use the right arrow button),
starting from the default UNIT # screen.

In the chart below shows the values that are avail-
able in each of these menus.

PROGRAMMING

To adjust and set a parameter value, enter the
program mode by pressing the center ENTER
button for approximately 3 seconds until the display
begins to flash.  You are now in the program mode
and the UP and DOWN buttons will take you
through the various values for a given parameter.

Find the desired value for the selected parameter
and use the RIGHT arrow button to save that value
and progress to the next parameter, while remaining
in the program mode.  (If the ENTER key is used,
the parameter value will be saved and program
mode exited.)

Proceed in this manner until all parameters have
been set to the desired value. Then press the
ENTER button to exit program mode and use the
UNIT key to proceed to the next DAD860 to be
programmed.

Pressing the LEFT arrow button while in program
mode will back up to the previous parameter without
saving the current parameter value to memory.

Once programming for a given DAD860 has been
completed, the information will be retained in the
units memory until it is reprogrammed, even when
power is removed.

RF LIST

OFF AIR
CATV STD
CATV HRC
CATV IRC

UNIT #

SN xx dB

BOOT UP

SYSTEM

DRAKE

DAD860

CH PLAN

USE LIST

MAN SEL

Select

MPEG #

Current

Channel

RF    #

MPEG  #

DAD860 CONTROLLER

MENU FLOW CHART

USE LIST

Select

Mode

Select
CH #

MPEG PGM
AUD PID

Select
CH #

Select

Audio

PID #

SCAN
 ADD

NEW

CLR LIST

CONFIRM?

CLEARING

CONFIRM?

Channel

Select

NEW

Scanning

ADD

Scanning

SCAN

TV TYPE

4:3

16:9

VERSION

NUMBER

MODE

VOLUME

0 - 100

AUDIO

1. ENG

2. SPA
3. FRE

MUTE SCR

BLUE SCR

NO VID

MUTE

WEAK SIG

NO MUTE

NO MUTE

CROPPED

STRETCH

LTR BOX

AFD/CROP

AFD/ LTR.

SCAN NEW
CLR LIST

SCAN ADD

MAN SEL

Содержание DAD860

Страница 1: ...Instruction Manual TM is a registered trademark of R L Drake LLC Copyright 2010 R L Drake LLC P N 3852492 D 2010 DAD860 and DAD860A Digital to Analog Decoders DAD860 LINK LOCK RS232 PROGRAM ...

Страница 2: ... be moved with care Quick stops excessive force and uneven surfaces may cause the product and cart combina tion to overturn The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The ex...

Страница 3: ...a or cable system is grounded so as to provide some protection against voltage surges and built up static charges Article 810 of the National Electrical Code ANSI NFPA 70 provides information with regard to proper grounding of the mast and supporting structure grounding of the lead in wire to an antenna discharge unit size of grounding conductors location of antenna discharge unit connection to gr...

Страница 4: ...AND AUDIO OUTPUTS Video Output Connector Impedance Level Format VBI Data Audio Outputs Level Aspect Ratio GENERAL Power Requirement DAD860 DAD860A Dimensions and Weight DAD860 DAD860A 54 MHz to 864 MHz Broadcast STD CATV HRC IRC 6 MHz 8VSB ATSC Standard 18 video formats 64QAM 256QAM Annex B Auto Detected 10 76 MS s 5 057 MS s 5 3606 MS s 26 to 30 dBmV 15 to 15 dBmV 12 to 15 dBmV Type F Female 75 O...

Страница 5: ...d power cable into the receptacle on the rear of the PSM121 Power Supply and attach a connector to the POWER receptacle on the rear of each of the DAD860s VMM modulators and the DAD860 Controller if used If the DAD860 Controller is used plug the supplied cable into the COMM receptacle on its rear panel You will note that the other end of this cable termi nates in ten three conductor female connect...

Страница 6: ... 5V 12V and GND to each device to which it is connected R4 RF IN This F type connector attaches to a CATV QAM or off air 8 VSB digital TV signal source R5 R6 AUDIO L R These two RCA Phono connectors provide left and right stereo audio output to a modulator or other suitable device RMM12 INSTALLATION OF DAD860AND DAD860A The DAD860A draws additional current from the power supply compared to the DAD...

Страница 7: ...e other end of which is terminated in ten numbered three conductor connectors The connector number corresponds to the unit number of the DAD860 to which it is connected R2 POWER Connector This three conductor connector connects to one of the twelve cables from the PSM121 power supply to supply power for the programmer FRONT PANEL INDICATORS CONNECTIONS REAR PANEL INDICATORS CONNECTIONS F7 DOWN But...

Страница 8: ...arameter value enter the program mode by pressing the center ENTER button for approximately 3 seconds until the display begins to flash You are now in the program mode and the UP and DOWN buttons will take you through the various values for a given parameter Find the desired value for the selected parameter and use the RIGHT arrow button to save that value and progress to the next parameter while ...

Страница 9: ...ress the RIGHT arrow button again This will take you to the RF MPEG screen in the main menu with the desired channel selected 7 Press the RIGHT arrow button again to save the value and proceed to the next parameter in the primary menu SCAN ADD This function allows storage of an additional channel to either a previously stored list or an empty list when the DAD860 is connected to a signal source 1 ...

Страница 10: ...will take the user directly to the VERSION NUMBER screen However if MUTE is selected the MUTE SCR screen appears with the choices of BLUE SCR blue screen and NO VID no video Use the up or down buttons to make the desired selection and press the right button to proceed to the Version Number screen Muting if selected will occur if the SNR drops to 15 dB and the unit will unmute when the SNR then rea...

Страница 11: ... 15 16 17 18 19 20 21 22 7 8 9 10 11 12 13 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Frequency in MHz 57 63 69 79 85 93 99 105 111 117 123 129 135 141 147 153 159 165 171 177 183 189 195 201 207 213 219 225 231 237 243 249 255 261 267 273 279 285 291 297 303 309 315 321 Channel Number CABLE TV CHANNELS Center of Channel Channel Number CABLE TV CHANNELS Center of Channel EIA NCTA Numeri...

Страница 12: ...1 527 533 539 545 551 557 563 569 575 581 587 593 599 605 611 617 623 629 635 641 647 653 659 665 671 677 683 689 695 701 707 713 719 725 731 737 743 749 755 761 767 773 779 785 791 797 803 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 Center of Channel Frequency MHz UHF BROADC...

Страница 13: ...orking days after it arrives at R L DRAKE if we have all the facts If we must call you it may take longer R L DRAKE is not responsible for damage caused by lightning nonprofes sional alterations acts of God shipping damage poor storage handling etc R L DRAKE will make note of any shipping damage upon receipt You will need to send proof of purchase to receive warranty service Typically a copy of th...

Страница 14: ... use are important to obtain proper performance from this product Therefore carefully read the Instruction Manual This warranty does not apply to any defect that R L DRAKE LLC determines is due to 1 Improper maintenance or repair including the installation of parts or accessories that do not conform to the quality and specifications of the original parts 2 Misuse abuse neglect or improper installa...

Страница 15: ...R L Drake LLC 230 Industrial Drive Franklin Ohio 45005 U S A Customer Service and Parts Telephone 1 937 746 6990 Telefax 1 937 806 1576 World Wide Web Site http www rldrake com ...

Отзывы: