Drain-All 870100 Скачать руководство пользователя страница 1

INSTALLATION

GUIDE

Model 1700

TM

The patented Model 1700

TM

was

designed for removing condensate from
compressed air systems.  Since it is total-
ly pneumatic, it does not require any
electricity and can be easily installed
using simple piping connections at any
point in a system including remote loca-
tions. It can handle pressures up to 170
PSIG and liquid temperatures up to
170

O

F.  It has 1/2” NPT inlet and outlet

ports and a full 1/2” smoothly contoured
condensate flow path. The industrially
robust, highly reliable Model 1700

TM 

has

few moving parts and at 21 pounds, can
stand up to the most demanding applica-
tions with minimal maintenance.

The Drain-All, Inc. Quality System is

ISO 9002 Certified

United States Patents: 4,444,217  4,562,855  4,574,829  5,004,004  5,014,735  5,983,919

Model 1700

TM

TM

Model 

1700

TM     

Part Number

# 870100

      Max Liquid Temp - ºF (ºC) 

170 (76.7)

Max Liquid Pressure - PSIG (BARG)

170 (11.7)

Control Air Min - PSIG (BARG)

40 (2.8)

Control Air Max - PSIG (BARG)

 130 (9.0)

Ht - 

"

 (cm)

11 (27.9)

Width - 

"

 (cm)

9-1/4 (23.5)

Depth (Inlet/BV) - 

"

 (cm)

10-1/2 (26.7)

Inlet/Outlet - 

"

 NPT

1/2

Control Air - 

"

 NPT

1/4

Balance Line - 

"

 NPT

1/8

Max Capacity GPM (l/h)

3 (681.4)

Weight - LBS (KG)

21 (9.5)

SPECIFICATIONS

INDEX 

Installation......2   Install Locations......12
Start-up & Troubleshooting.................3
Dimensional Print...............................4
Product Technology, How It Works.......5
Component Parts Drawing...................6
Parts & Materials of Construction.........7
Frequently Asked Questions..................8 
Drain-All Solves Problems....................9
Team Drain-All...................................10
Warranty......11        Warranty Card ......11

Drain-All, Inc.

PO Box 609
1170 Topside Road
Louisville, TN, USA
37777

Phone: 865-970-9290

Fax: 865-977-6658

E-mail: [email protected]

WEB SITE: Drain-All.com

Page 1

022802 Model 1700-IG

Содержание 870100

Страница 1: ...tents 4 444 217 4 562 855 4 574 829 5 004 004 5 014 735 5 983 919 Model 1700TM TM Model 1700 TM Part Number 870100 Max Liquid Temp ºF ºC 170 76 7 Max Liquid Pressure PSIG BARG 170 11 7 Control Air Min PSIG BARG 40 2 8 Control Air Max PSIG BARG 130 9 0 Ht cm 11 27 9 Width cm 9 1 4 23 5 Depth Inlet BV cm 10 1 2 26 7 Inlet Outlet NPT 1 2 Control Air NPT 1 4 Balance Line NPT 1 8 Max Capacity GPM l h 3...

Страница 2: ...n follow the start up instructions for adjusting the opening of the balance line needle valve There will be very little air loss to atmosphere NO MANIFOLDS There cannot be multiple system drains through a manifold to one Model 1700TM This will not work because all system drains will not be of the same pressure Therefore the liquid from the higher pressure drain lines will bypass the Model 1700TM a...

Страница 3: ...he Model 1700TM must be below the bottom of the vessel being drained 7 Once properly installed no further adjustments to the Model 1700TM are nec essary The Model 1700TM is fully auto matic discharging on demand as needed when liquid accumulates TROUBLESHOOTING 1 Water does not enter A Balance line isolation shutoff valve is closed which does not allow liquid to enter the Model 1700TM Solution Adj...

Страница 4: ...Page 4 MODEL 1700TM DIMENSIONAL PRINT 022802 Model 1700 IG ...

Страница 5: ... valve starting the discharge of accumulated liquid When the correct amount of liquid has been discharged leaving a liquid seal in the reservoir the float has been lowered to a point where the float magnet is below the center tube magnet In this position the float magnet repels the center tube magnet back upward against the valve stem orifice which seals off the control air flow to the actuating c...

Страница 6: ...Page 6 MODEL 1700TM COMPONENT PARTS DRAWING 022802 Model 1700 IG ...

Страница 7: ...ID x 0 069 T Viton Brown 1 14 200170 Center Tube 1 150 Dia x 4 500 L O ring Seal 6061 T6 Aluminum 1 15 302270 Hex Bolt 1 2 13 x 10 L Zinc Plated Steel 4 16 300314 Pneumatic Cylinder 2 Dia 40 130 PSI Stainless Steel Body and Rod Aluminum Ends 1 17 100480 Float Polyurethane Bullet Shaped 1 18 302200 Sleeve O ring 5 519 ID x 0 137 T Viton Brown 2 19 100300 Sleeve 6 ID x 7 L x 125 T Epoxy Fiberglass T...

Страница 8: ...e control air line be hooked together via a tee connection No Do not do this Each of these air lines has its own specific purpose and should never be tied together The con trol air should be the cleanest driest air available since it supplies air to the con trol circuit to operate the pneumatic actu ating cylinder which functions best and lasts longer if clean dry air is used The balance line allo...

Страница 9: ...ion With the addition of a Drain All cycle counter on the Drain All unit it is easy to track how much liquid is produced over any period of time This is particularly important for benchmarking system equipment performance and per forming trend analysis For example it is essential to know the quantity of liquid produced by a compressed air system to properly size oil water separators The counter co...

Страница 10: ...ups The Model 1700TM center fore ground in the photo above is Drain All Inc s flagship product used in facilities around the world to remove liquid from compressed air system applications In addition to the Model 1700TM there are other Product Groups that can include different models for specific require ments There are also situations where specific applications require the use of compo nents mat...

Страница 11: ...at Drain All Inc s election and cost to the repair or replacement of the defective part that does not comply with any applicable warran ty and shall in no event exceed the original purchase price of the unit Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limi tation may not apply to purchaser All claims under this warranty should be made by...

Страница 12: ...rst four applications above the balance line is connected back to the vessel that is producing the condensate The pres sure on the incoming condensate to the trap and the pressure in the balance line are the same and the trap is filling by gravity For this method the top of the trap must be below the bottom of the vessel being drained Method 2 Connect the balance line port to the head er pipe leav...

Отзывы: