How Does the BMS Protect the Batteries?

 

All Battle Born Batteries come with a built-in battery management system (BMS) that protects the cells from many 

strenuous circumstances to protect the life cycles of the cells and your electrical system from potential damage. The BMS 

in the BB1

275

 allows for 100 Amps continuous, 200 Amp surge for 30 seconds, and 1/2 second surge for loads over 200 

Amps. All of our BMS' protect against the following conditions: 

High Voltage Disconnect (> 14.7V)

 

If an individual cell voltage exceeds a prescribed threshold during charging, the BMS will prevent a charge current from 

continuing. Discharge is always allowed under this condition. If the batteries have not been balanced for a long time, 

high voltage disconnect could occur at a lower voltage. The batteries will rebalance after several full charges. 

Low Voltage Disconnect (< 10.6V)

 

If an individual cell falls below a prescribed threshold during discharge, the BMS will prevent further discharge. Although 

the battery is in “low-voltage disconnect” mode, it will still allow a charging current. 

NOTE: Many chargers must detect a voltage over 10V to send a charge to the battery. Please be aware that some chargers may not sense a battery in low voltage 

disconnect and you may need to jump 

it 

with a 12V source to “wake up” the battery. You should jump your battery within 24hrs of entering low voltage disconnect 

otherwise you risk damaging your battery and voiding the warranty. 

High Temperature Charging and Discharging (> 135°F/57.2°C)

 

The BMS will not allow a charging or discharging current if the internal temperature of the battery has reached 135°F 

(57.2°C). 

Low Temperature Charging (< 25°F/-3.9°C)

 

The BMS will not allow a charging current under 25°F (-3.9°C) but will continue to discharge down to -4°F (-20°C). 

NOTE: The BB

1

275

 has an operating temperature range of 

-

4°F (-20°C) to 135°F (57.2°C).

High Current Discharge Surges

 

The BMS will not allow a current that exceeds 200 (+/- 5%) Amps for more than 30s, or anything larger for 0.5s. After a 

high current disconnection, the battery will automatically reconnect after 5 seconds. 

Short Current Discharge Surges 

Our BMS has built-in short circuit protection. If the short circuit protection is tripped, the BMS will shut the battery down 

and will remain disconnected until you remove the battery cables. While the battery cables are disconnected, we suggest 

taking the voltage of the battery with a voltmeter. If it reads above 10V, reconnect the battery cables. If you are 

unsuccessful at obtaining a voltage reading above 10V, please give our technical support team a call.

Figure 5: As a rule of thumb, you can use these numbers as a guideline.

 

Cable QR Code 

Balancing of Cells

 

A passive balancing process is activated by 

the BMS at the top of each charge cycle 

when the battery voltage exceeds around 

14.2V. This ensures that all the cells remain 

at the same state of charge, which helps 

pack longevity and performance. 

How to Properly Size Cables   

for a System Install

 

When considering cable sizing there are a 

few factors to consider. First, what is the 

size of the load you are powering with the 

battery bank? Second, how far away from the battery is the load? 

You can do voltage drop calculations to see if you need to step up your cable size. Fig. 5 is a chart to use for 

reference. Do keep in mind that cables are only capable of carrying a certain amperage and you should 

verify the specifications of your cable and the power draws before implementing them into your system to 

avoid potential failures and damage.

Содержание Battle Born Batteries BB1275

Страница 1: ...Dragonfly Energy Battle Born Batteries Dragonfly Energy Corp Phone 855 292 2831 Email info battlebornbatteries com Model BB1275 Group 24 12V 75Ah Deep Cycle LiFePO4 Battery Manual and Installation Guide ...

Страница 2: ...y Charge the Batteries 5 How to Properly Size Cables for a System Install 6 How to Incorporate Fuses Into System Install QR for Blog 7 How to Properly Store Batteries QR for Blog 7 How to Maintenance the Batteries 7 Warranty 7 Return Policy 8 Refund Policy 8 Shipping 8 How to Properly Recycle and Dispose of the Batteries 7 QR Codes will appear throughout the manual linking to FAQ videos that may b...

Страница 3: ...and negative terminals These are labeled and color coded red for positive black for negative 2 Determine which finishing hardware set you will use Verify that your bolt can fully seat into the nylok insert of the nut If multiple lugs are used longer bolts may be required for the bolt to fully seat into the nylok insert of the nut 3 Connect your cable lugs to your battery terminal with the previous...

Страница 4: ... and color coded red for positive black for negative 2 Determine the appropriate finishing hardware set you will use Verify that your bolt can fully seat into the nylok insert of the nut If multiple lugs are used longer bolts may be required for the bolt to fully seat into the nylok insert of the nut 3 Make the proper cable connections to the positive of the first battery Please reference Fig 1 fo...

Страница 5: ...ng to your battery terminals DO NOT finger tighten Use a torque wrench to torque your hardware to the specification of 9 to 11 ft lbs Failure to adequately secure connections can result in severe damage and will void your warranty 6 Connect the other end of your cable to the positive terminal of the other battery you are connecting to Repeat step 4 7 Repeat steps 3 6 for additional batteries but D...

Страница 6: ...Temperature Charging 25 F 3 9 C The BMS will not allow a charging current under 25 F 3 9 C but will continue to discharge down to 4 F 20 C NOTE The BB1275 has an operating temperature range of 4 F 20 C to 135 F 57 2 C High Current Discharge Surges The BMS will not allow a current that exceeds 200 5 Amps for more than 30s or anything larger for 0 5s After a high current disconnection the battery wi...

Страница 7: ...e Battle Born batteries to a 100 state of charge Then disconnect the battery from any loads by removing the negative cable from one battery On average the batteries lose approximately 2 3 capacity per month This is subject to increasing if stored in extreme environmental conditions How to Maintain the Batteries Battle Born Batteries require very little maintenance If your batteries are in series a...

Страница 8: ...al packaging Original packaging must be in the same condition as it was received otherwise you may be responsible for a restocking fee If the item has been installed used or no longer has the original packaging we will assess a restocking fee that will be shared when the return merchandise authorization RMA is issued Items 60 days past the original invoice will be reviewed at Battle Born s discret...

Отзывы: