26 Installation
(for qualified installers only)
Travis Industries
4101014
100-01257_000
Rear Vent Configuration with Horizontal Termination (no vertical rise)
•
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Optional 45° Elbow
Termination
See the charts below to
determine maximum vent
3 feet
915mm
0 feet
mm
0 feet
mm
4' (max) 610mm
• Exhaust Restrictor # 0 (stock)
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
Vent with No 45° Elbow
3 feet
915mm
0 feet
mm
0 feet
mm
2' (max)
1.2m
Vent with 1 45° Elbow
• Min. 4" (102mm) Horizontal Section
• Max. 24" (610mm) Horizontal Section(s)
• Min. 4" (102mm) Horizontal Section
• Max.48" (1.2m) Horizontal Section(s)
• Exhaust Restrictor # 0 (stock)
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)