User Manual for LoRaWAN End Nodes - CPL01 LoRaWAN Outdoor Pulse/Contact Sensor
OK
AT+PWORD=999999
Set password
OK
Downlink Command:
No downlink command for this feature.
3.3 Quit AT Command
Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands.
AT Command: AT+DISAT
Command Example
Function
Response
AT+DISAT
Quit AT Commands mode
OK
Downlink Command:
No downlink command for this feature.
3.4 Enable / Disable Alarm
Feature: Enable/Disable Alarm for open/close event. Default value 0.
AT Command:
Downlink Command:
0xA7 01
//Same As AT+DISALARM=1
0xA7 00
// Same As AT+DISALARM=0
3.5 Alarm Base on Timeout
CPL01 can monitor the timeout for a status change, this feature can be used to monitor some events such as door
opening too long etc. Related Parameters are:
1. Keep Status: Status to be monitor
Keep Status = 1: Monitor Close to Open event
Keep Status = 0: Monitor Open to Close event
2. Keep Time: Timeout to send an Alarm
Range 0 ~ 65535(0xFFFF) seconds.
If keep time = 0, Disable Alarm Base on Timeout feature.
If keep time > 0, device will monitor the keep status event and send an alarm when status doesn’t change after
timeout.
Page 26 / 32 - last modified by Xiaoling on 2022/07/01 18:01