This  Instruction  for  Use,  for  the  Dräger  Regis  300  Entry  Control  Board 

(ECB), must be used in conjunction with the instructions supplied with the 

associated self contained compressed air breathing apparatus (SCBA).  The 

instruction  provides  basic  information  for  the  operational  use  of  the  unit.  

The  operational  deployment  control  procedures  adopted  are  however  the 

responsibility of the end user, or as defined by any national legislation in the 

country of use.

General

 Use of this equipment requires training and observance of this Instruction 

for Use.

 Use  the  equipment  for  the  purpose  specified  in  this  instruction,  or  as 

confirmed in writing by Dräger.

 Only trained competent personnel should inspect the equipment at regular 

intervals and a record kept of such inspections and service.

 Notify Dräger if there is a component fault or failure.

Power Packs - Batteries

Used Batteries

 Do Not incinerate – risk of explosion.

 Do Not puncture the battery casing – risk of explosion.

 Special Waste Disposal – according to local waste disposal regulations.  

Information on this subject should be available from the local environmental 

and regulatory agencies and waste disposal companies.

Liability Statement

Responsibility for the reliable function of the equipment transfers to the owner 

or operator when serviced or repaired by untrained personnel, or when used 

in a manner not conforming to its intended use.

Dräger cannot be held responsible for damaged caused by non-compliance 

with the recommendations given above. 

The Warranty and Liability provisions for the Terms of Sale and Delivery are 

likewise not modified by the recommendations given above.

Intended Use

The Dräger Regis 300 ECB is a battery powered unit providing a means 

of  electronically  monitoring  the  deployment  time  for  up  to  three  teams 

of  SCBA  wearers.    A  panel  on  the  face  of  the  ECB  allows  the  user  to 

manually record relevant additional notes and data with regard to the teams 

or individuals.  The scope of the notes/information will of course depend 

on the deployment procedures established by the end user.  Audible and 

visual alarms provide the user with indications of the various preset stages 

during the deployment period.

Description

The Dräger Regis 300 ECB is supplied with:

 

Plastic  housing  with  integral  carrying  handle  (ECB),  2off  Pen  holders 

and  three  holes  at  the  base  of  each  crew  column  for  the  location  of 

identification tags.

  Clamping strip and DIN A4 transparency sheet.

  Four rubber protectors for the corners of the ECB.

  Non water soluble felt pen.

  9V Battery.

  Fastening block with lock.

  Instructions for Use.

The ECB contains the following:

LCD Displays

Three LCD clocks that display time data - showing the remaining deployment 

time (in minutes) for each deployed crew.

LED Displays

Three LED’s that illuminate “RED” when an alarm is active.  These are each 

situated above the LCD clocks.

Push Buttons

1off Plus (+) button.

1off Minus (-) button.

3off Start/Stop buttons, Crew 1, Crew 2 and Crew 3.

1off Clock Display button – Real time is displayed in the third LCD.

1off Illumination button – Backlight

 

press to illuminate, release to switch off.

 

 

Writing Surface

 

The A4 size surface contains five fields for manually entering details for up to 

three deployed crews,

i.e,

 Time/pressure - at start of deployment.

 Time/pressure at 1/3 of deployment.

 Time/pressure at 2/3 of deployment.

 Time/pressure at end of deployment.

 Field for comments and additional relevant data.

The DIN A4 transparency sheet is located over the writing field and secured into 

position using the clamping strip.  The completed transparency can be removed 

to be used for producing a documentation record of the deployment scenario.

Deployment Times

A  dip  switch  arrangement  is  located  on  the  circuit  board  inside  the  main 

housing.  A table, printed on the board next to the switch, identifies the switch 

configuration settings for the required deployment time, i.e. 20, 30, 60 or 

90 minutes.  The ECB is supplied with a default setting of 30 minutes.

Transmitter

Located  inside  the  housing  is  a  wired  aerial  connected  to  a  transmitter.    This 

arrangement is able to transmit a signal to a remote external alarm unit (optional).

Technical Data

Dimensions

Height 

 

 

410mm

Width 

 

 

330mm

Depth 

 

 

62mm

Weight

   

 

1.5Kg approx.

Battery

9V Alkaline

e.g. Duracell  MN1604

Battery Life - approx. 2 years

Fitting the Battery

The ECB is supplied with the battery not fitted.

 Slide and remove the battery housing cover from the left hand rear of the 

ECB.

 Correctly connect the terminals of the flying lead connector to the battery, 

then insert the battery into the compartment.

 Refit the battery housing cover.

Note: When not using the ECB for long periods it is recommended that 

the battery be removed.

Setting the Real Time Clock 

 Press and hold down the ‘Clock’ Display button.  The time (in hrs. – mins) 

will illuminate in the No 3 Crew column.

 While holding down the button;

  Use the ‘+’ button to increase and change the hours,

  Use the ‘-‘ button to increase and change the minutes.   

 When the correct time is set – release the ‘Clock’ display button.

Function Tests

Alarm Signals

 Press the Start/Stop buttons 1, 2 and 3 of the crew columns.  A single 

audible  ‘Bleep’  will  be  emitted  as  each  LCD  displays  the  defaulted 

deployment time.  An alternating flashing bar to the left of the display 

indicates that the time clock has commenced the ‘count down’.

  An audible signal and a flashing ‘RED’ LED will activate at:

 1/3 of deployment (20 minutes at 30 minute default).

 2/3 of deployment (10 minutes at 30 minute default).

 end of deployment (0 minutes at 30 minute default).

 Field for comments and additional relevant data.

Note: Unless switched ‘Off’ at the end of the deployment time, the 

time clock will continue ‘count down’ for up to minus 99 minutes.

 To  acknowledge  and  stop  the  alarm,  briefly  press  the  associated  crew 

column start/stop button.

 To end a deployment period – press and hold down the start/stop button 

until the alternating flashing bar to the left of the display stops then release 

the  button.    The  time  shown  in  the  display  will  remain  for  a  further  3 

seconds, then it switches ‘Off’. 

Important Note: To perform a 'speed up' function test – hold down 

the relevant start/stop button and at the same time briefly press 

the (-) button to count down in one minute increments down to 

e.g. 6 minutes and then wait until 1/3 time has elapsed (in this 

case until 4 minutes is reached) - wait and check activation of the 

first audible and visual alarm - briefly press the associated crew 

column start/stop button to confirm/cancel the alarm.

Allow the count down to continue until 2/3 time has elapsed (in 

this case until 2 minutes is reached) wait and check activation of 

the  first  audible  and  visual  alarm  -  briefly  press  the  associated 

crew column start/stop button to confirm/cancel the alarm.

Allow the count down to continue until the display shows 0 time 

- wait and check activation of the final audible and visual alarm 

-  briefly  press  the  associated  crew  column  start/stop  button  to 

confirm/cancel the alarm.  Switch 'Off' the unit. 

Battery Warning

 Press and hold the Clock display button to check for remaining battery life.

  

  If  the battery is OK - FULL is displayed in all the LCD's.

  

  If all LCD's display - empty battery icon - Battery Low – remaining 

deployment time is 2 hours.

  

  If  1+2  LCD's  display  -  flashing  empty  battery  icon  -    immediately 

replace the battery.

Operational Use

A competent person (Controller) must be nominated to control and monitor 

an  Entry  Control  Board  (ECB)  and  to  direct  and  instruct  all  wearers  of 

breathing apparatus (SCBA) at an incident.

A safe and secure Entry Control Point (ECP) for the ECB should be established 

from which the Controller is able to effectively control the adopted deployment 

procedures. 

Important Note: The defaulted Deployment Time should be preset to 

correspond to the capacity of the selected cylinder.

 At  the  start  of  the  deployment  of  breathing  apparatus  at  an  incident,  it 

should be decided which Crew is to be assigned to which LCD column i.e. 

1, 2 or 3.

 At the bottom of each Crew column (in the lower edge of the ECB) are 

three holes into which the Controller can locate the identity tags of each 

crew member assigned to the column.

 The  Controller  should  record  in  the  relevant  field  of  the  A4  transparency  - 

the current time and the cylinder pressure of each crew member.  Additional 

information may be added such as, area to be deployed, type of incident etc.

 Immediately a Crew is deployed for entry into a risk area, the Controller must 

press the associated Start/Stop buttons 1, 2 or 3.  A single audible ‘Bleep’ 

will  be  emitted  as  the  LCD  displays  the  defaulted  deployment  time.    An 

alternating flashing bar to the left of the display indicates that the time clock 

has commenced the ‘count down’.

 Any additional important information received by radio, or other means 

during  the  incident,  should  be  noted  in  the  relevant  field  of  the  A4 

transparency.

 An audible signal and a flashing ‘RED’ LED will activate at:

  1/3 of deployment (20 minutes at 30 minute default).

  2/3 of deployment (10 minutes at 30 minute default).

  end of deployment (0 minutes at 30 minute default).

 To acknowledge and stop each alarm, briefly press the associated start/

stop button.

Important  Note:    During  the  incident,  the  SCBA  wearers  must 

conform to there operational training procedures and requirements 

for the equipment, taking into account ‘Time to Whistle’, withdrawal 

time from the risk area etc. 

After Use

Safety Warning: Do Not remove the SCBA until in a safe area, clear 

of the hazard.

 All Crew members must return to the Entry Control Point (ECP) and the 

Controller to ensure that the end of deployment procedure is correctly 

followed.

 At the ECP, the Controller will identify each member of the Crew then 

remove the relevant identity tag from the base of the ECB and hand it over 

to the wearer.  The cylinder pressure and actual time out of each wearer 

should be recorded in the relevant field of the A4 transparency. 

 When all Crew members have returned and been identified - press and 

hold  down  the  start/stop  button  of  the  relevant  Crew  column  until  the 

alternating flashing bar to the left of the display stops then release the 

button.  The time shown in the display will remain for a further 3 seconds, 

then switch ‘Off’.

 

After Care

The ECB does not require any routine attention by the user other than a general 

visual inspection after use.

Do Not

 immerse the ECB in cleaning fluids or use abrasive cleaning agents.  

When considered necessary by the user, remove dirt and contaminants by 

carefully cleaning using a lint free cloth dampened in a mild soap solution, 

and then apply a proprietary antistatic cleaning agent to a clean lint free cloth 

and clean the surfaces of the ECB.  

Note:  If  board  has  been  opened  to  change  deployment  time  setting, 

when sealing up the housing halves - DO NOT over tighten the securing 

screws.

Safety Note: Do Not use organic solvents such as Acetone, White 

Spirit, Trichloroethylene, or similar. 

Carry out Functional Tests on a regular basis to ensure correct functionality 

of the unit.

Order Codes - Accessories

External Signal Alarm 

 

 

 

R54994

Identity Tags – 30minute – colour Red.   

 

R54532

Identity Tags – 120minute – colour Blue. 

 

R54533

Identity Tags – 60 minute – colour Yellow. 

 

R54534

All identity tags are supplied with a spring hook.

Dräger, while endeavouring to ensure correctness of statements of 

fact and advice contained in this publication; gives no guarantee 

or  warranty  in  respect  thereof,  and  accepts  no  liability  for  any 

mis-statement or inaccuracy in publication, or for any omission 

therefrom.

Dräger Safety UK Limited

Ullswater Close

Riverside Business Park

Blyth
Northumberland NE 24 4 RG

Tel:   (01670) 352891

Fax:  (01670) 356266

3355781 : Edition 2 : January 2008 : Subject to Modification - (A3-D-P)

 

regis 300 entry control board

scba entry control

Instructions for Use