Technical Data
04 | Dräger LAR 7000
Basic Unit
Principal of operation
closed and semi-closed circuit, with constant dosage and lung demand valve
Diving depth
0 to 32 fsw in closed circuit
0 to 78 fsw in semi-closed circuit
Diving endurance
240 minutes at 39° F water temperature
Breathing gas
All depths are at a PpO
2
of 1.6 ata.
0 to 20 fsw pure oxygen
0 to 55 fsw pre-mixed gas B, 60 % O
2
, 40 % N
2
optional with upgrade kit:
0 to 98 fsw pre-mixed gas C, 40 % O
2
, 60 % N
2
0 to 128 fsw pre-mixed gas D, 32.5 % O
2
, 67.5 % N
2
Breathing bag
flexible volume approx. 5.5 l
available volume approx. 10 l
Sodalime
DiveSorb
®
Pro; approx. 5 lb. 1 oz. per filling
Relief valve
adjustable from approx. 4 mbar to 90 mbar
Magnetic signature
conforms to STANAG 2897, Class A
Acoustic signature
tested in accordance with AMP 15
Dimensions
lenght 17 in., width 13 in., depth 7.5 in.
Weight
in air
in water (ready to dive)
approx. 13 kg
neutral
Operating temperature
29° F to 104° F
Storage temperature
-22°F to 122° F
CYLINDER DATA
Oxygen Cylinder
low magnetic (LM)
Volume
14 cu. ft.
Diameter
5.25 in.
Nominal Pressure
3000 psi
Connection
G 3/4”
Material
aluminium alloy
Approval
DOT3AL
Positioning
at the apparatus
Ordering Information
Dräger LAR 7000 without harness
T 16 410
Cylinders
Oxygen cylinder - LM, 1,9 l, with valve, black color
T 17 353
Test Accessories
Pre Dive Test Unit (Pre Dive)
T 14 992
Dosage Test Unit (Workshop)
T 14 433
Multi-Purpose Test Unit (Workshop & Pre Dive)
T 15 007
Accessories
Transport case, plastic composite, large with inlets
T 16 956
Tactical Harness 1000 – Basic version, size M
T 92 161
Tactical Harness 1000 – Basic version, size L
T 92 165
Tactical Harness 1000 – Basic version, size XL
T 92 166