background image

www.drtrustusa.com

www.drtrustusa.com

10

11

NOTE

       Always check if the lens is clean.

       accuracy as described in the section “Temperature taking tips” and

       If the eyebrow area is covered with hair, sweat or dirt, please clean the

       body temperature. Please be aware of the factors that in uence the

       forehead temperature can  uctuate up to 1 ºF/0.5 ºC from your actual

       Always make sure the user and the thermometer will have been in the

       “WARNINGS AND PRECAUTIONS”.

       The normal temperature range on the forehead is approximately

       The forehead measurement is an indicative reading. The measured

       between 35.4 °C and 37.4 °C.

       same room for at least 30 minutes prior to the measurement.

       area beforehand to improve the reading accuracy.

6.2.  Ear Temperature Measurement

        Press & release the power button in 1 second with the beep sound.

        Press the power button to power on.

        The body temperature is shown on the LED display.

        Take off the probe cover.

        Insert the probe into the ear canal.

       Please make sure that the ear is clean, with no earwax or obstructions.

       Therefore, always take the temperature in the same ear.

Note
       The normal ear temperature range is approximately between 35.5 °C
       and 37.7 °C.

       Insert the probe straight into the ear canal.
       The right ear reading may differ from the reading taken at the left ear.

       It is important to point the probe lens of the ear thermometer toward

       To straighten the ear canal, gently pull on the outer ear in the

       Each ear canal has a slightly different shape, be sure to check it before
       taking temperature readings. 

       direction of the rear of the head.

       the eardrum and its periphery inside the ear. 

6.3.   Recall 32 Sets of Memory Data

       of screen, it means the  rst memory, then the number ‘1’ disappears

The thermometer can store 32 sets of measurement data, when the data is 
full, the last one will always replace the  rst one. If you want to review the 
previous measurement data, in the state of Thermometer shutdown;

       seconds, thermometer will shut down and save the setting

       Press the setting button for about 3 seconds until you see the ‘M’ 
       symbol Flicker on the screen, then release the button.
       Press the button, you can see the number ‘1’ appears on the right side

       quickly and pop up the  rst remembered temperature value. 
       Press the button one by one, so you can see all the remembered

       After reviewing the memory data, press the button for about 5

       automatically.

       temperature values in turn for all of memories. 

In Ear Mode, the symbol        shows on screen.

Safety Measures

        small. 

        Children aged 1 year to adult: Pull the ear up and back.

        Be careful when taking temperature on a child, whose ear canal is

        canal may get injured.

        Do not force the thermometer into the ear canal. Otherwise, the ear

          When taking the temperature on an adult, gently pull the ear up and
          back to make sure the ear canal is straight, so that the temperature 
          probe can receive an infrared ray from the eardrum.

O

O

6.4. 

  C and  F Conversion

       Press the Setting button for about 6 seconds until you see the ‘

       symbol or the ‘

’ symbol flicker on the screen, then release the

       button. 

If you want to convert 

 to 

 or 

 to 

, in the state of thermometer 

shutdown;

Содержание Homedoc 602

Страница 1: ...has now become easier with the coming of the monitoring devices which can be convenientlyusedathomesandevenonthego DrTrust strives to enhance the quality of lifestyle by providing with the most trustedand innovative health care and wellness products Being a renowned global leader in health care products Dr Trust ensures that our technically efficient team works dynamically and tirelessly to provide ...

Страница 2: ...ature measurement 6 5 Turn on off the buzzer 6 6 Set threshold for low fever 4 STRUCTURE COMPONENTS 4 1 Body parts 6 7 Set threshold for high fever 6 8 Turn off 6 9 Battery replacement 9 KEY FACTORS THAT INFLUENCE EAR TEMPERATURE READINGS 7 TIPS TO MAKE CORRECT TEMPERATURE MEASUREMENTS 8 MULTI MEASUREMENTS REQUIREMENTS 16 CUSTOMER SUPPORT 15 PACKING LIST 10 2 Disinfection 14 DECLARATION 12 SPECIFICA...

Страница 3: ...zzergivesa beep cue 1 2 Normal Body Temperature Range Normal body temperature has a range The following table shows that this normal range also varies by measuring different sites Therefore readings from different site should not be directly compared Tell your doctor what type of thermometer you have used and what part of body you have measured Alsokeepthisinmindifyouarediagnosingyourself 1 3 Intend...

Страница 4: ...emoryareeasytorecall LightinganorangeLED intelligentlowfeveralarm LightingaredLED intelligenthighfeveralarm Automaticshutdownmakesitenergysaving Usefulforbabies adults andseniorcitizens Twooperationmodes foreheadandearmeasurementmode Turnonoroffthebeeporsoundfunction Accurate reliablewithlowbatteryconsumption 4 STRUCTURE COMPONENTS 4 1 Body Parts Theinfraredthermometerconsistsofashell aLEDdisplaysc...

Страница 5: ...ed solely on temperature readings to determine the severity of When You Need to Receive Medical Attention activity seizure muscle pain shivering stiff neck pain when urinating etc irritability vomiting diarrhea dehydration changes in appetite or 1 Please consult your doctor if you see symptoms such as unexplained 2 People who are on antibiotics analgesics or antipyretics should not be their illness...

Страница 6: ...re taking temperature readings direction of the rear of the head the eardrum and its periphery inside the ear 6 3 Recall 32 Sets of Memory Data of screen it means the rst memory then the number 1 disappears The thermometer can store 32 sets of measurement data when the data is full the last one will always replace the rst one If you want to review the previous measurement data in the state of Ther...

Страница 7: ...nt range is from In the state of shutdown hold pressing the Setting button for 12 thermometer will shut down and save the setting automatically 6 7 Set Threshold for High Fever This thermometer has preset 38 0 100 4 as an alarm temperature for high fever However 38 0 100 4 is only a classic reference value At this temperature different people feel different some feel bad but others feel not too bad ...

Страница 8: ...ual from the situation and wait 20 Use the untreated ear if prescription ear drops or other ear minutes prior to taking a temperature reading medications have been placed in the ear canal Cau ons 10 MAINTENANCE AND CARE 10 1 Maintenance Never use abrasive cleaning agents thinners or benzene for cleaning and never immerse the instrument in water or other cleaning liquids Take care not to scratch th...

Страница 9: ...www drtrustusa com www drtrustusa com 16 17 12 SPECIFICATIONS Dr Trust Homedoc Ear Forehead Thermometer ...

Страница 10: ...nce and Manufacturer s Declaration Cau ons Infrared Thermometer needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided for in the ACCOMPANYING DOCUMENTS affect infrared thermometer The Infrared Thermometer should not be used adjacent to or stacked with other equipment Portable and mobile RF communications equipment can Guidan...

Страница 11: ...quipment and the EQUIPMENT or SYSTEM for EQUIPMENTandSYSTEMSthatarenotLIFE SUPPORTING 15 PACKAGE CONTENTS No Name Quantity 1 Infrared Thermometer 1 2 Pouch 1 3 Battery AAA optional 2 4 User Manual 1 17 CUSTOMER SUPPORT www drtrustusa com customercare nureca com drtrust drtrustisin COPYRIGHT 2018 DR TRUST ALL RIGHTS RESERVED ...

Отзывы: