4.4 Examples of changing weather icons:   

         

 

 

4.5 Storm warning indicator 

 

The storm threshold can be set to suit the user’s requirement for storm forecasting 
from 3-9hPa (default 4hPa). When there is a fall over pressure threshold within 3 
hours, the storm forecasting will be activated, the clouds with rain icon and tendency 
arrows will flash for 3 hours indicating the storm warning feature has been activated. 
 
Notes to pressure sensitivity setting for weather forecasting:   
The pressure threshold can be set to suit the user’s requirement for weather 
forecasting from 2-4hPa (default 2hPa). For areas that experience frequent changes in 
air pressure requires a higher setting compared to an area where the air pressure is 
stagnant. For example if 4hPa is selected, then there must be a fall or rise in air 
pressure of at least 4hPa before the weather station will register this as a change in 
weather.  
 

 
 

5. Program Mode 

The base station has five keys for easy operation: SET key, ALARM key, MIN/MAX 
key  + key and SNOOZE/LIGHT key. And there are four program modes available: 
Quick Display Mode, Setting Mode, Alarm Mode and Min/Max Mode. 
 
The program mode can be exited at any time by either pressing the SNOOZE/LIGHT 
key, or waiting for the 10-second time-out to take effect. 

 

5.1 Quick Display Mode 

- While in Normal Mode, press the SET key to enter the Quick Display Mode as follow: 

1.    Outdoor Temperature / Dew point (press the MIN/MAX key or + key shifts the 

display between outdoor temperature and dew point) 

2.    Absolute pressure / Relative pressure (press the MIN/MAX key or + key shifts the 

display between the absolute pressure and relative pressure) 

 
- press the SET key to accept the change and advance to the next display mode. 

Continues to press the SET key to toggle through the display mode until return to the 
normal Mode 

 
 
 
 

Содержание WH1170

Страница 1: ...1 WIRELESS WEATHER STATION INSTRUCTION MANUAL This Operation Manual is part of this product and should be kept in a safe place for future reference It contains important notes on setup and operation Page ...

Страница 2: ...ating problems please take note of battery polarity before when inserting any Alkaline Batteries permanent damaged could be introduced by inserting the battery in wrong direction Use good quality Alkaline Batteries and avoid rechargeable batteries 1 Insert two AAA batteries into the remote sensor 2 Insert three AA batteries into the weather station 3 Wait 3 minutes or until the outdoor temperature...

Страница 3: ...e your remote sensor outdoors and set your time if no RCC reception is possible If there is no temperature reading in the indoor station make sure the units are within range of each other or repeat the battery installation procedure If a key is pressed before the weather station receives the temperature signal you will need to follow the battery installation procedure again Please wait 10seconds b...

Страница 4: ...sor Note To achieve a true temperature reading avoid mounting remote sensor in direct sunlight We recommend that you mount the remote sensor on an outside North facing wall obstacles such as walls concrete and large metal objects will reduce the range To wall mount use 3 screws to affix the wall bracket to the desired wall plug in the remote sensor to the bracket 4 LCD overview 4 1 LCD overview Th...

Страница 5: ...ur weather icons Sunny partly Cloudy Cloudy and Rainy represent the weather forecasting There are also two weather tendency indicators to show the air pressure tendency between the weather icons The weather forecasting is based upon the change of air pressure 4 3 Weather tendency indicator The weather tendency indicators arrow is located between the weather icons to show the air pressure tendency ...

Страница 6: ... pressure of at least 4hPa before the weather station will register this as a change in weather 5 Program Mode The base station has five keys for easy operation SET key ALARM key MIN MAX key key and SNOOZE LIGHT key And there are four program modes available Quick Display Mode Setting Mode Alarm Mode and Min Max Mode The program mode can be exited at any time by either pressing the SNOOZE LIGHT ke...

Страница 7: ... will change according to new units but it might cause resolution loss due to its internal calculation algorithm 5 2 1 Setting Calibrated Humidity The display console allows you to calibrate both the indoor and outdoor humidity Humidity is a difficult parameter to measure accurately and drifts over time The calibration feature allows you to zero out this error To calibrate humidity you will need a...

Страница 8: ...llow the sensor to stabilize for 24 hours Compare this temperature to the fluid thermometer and adjust the console to match the fluid thermometer To calibrate indoor or outdoor temperature in the Set Mode with indoor or outdoor temperature flashing press the key or MIN MAX key to increase or decrease the temperature setting in increments of 0 1 degC or 0 18 degF to match the calibrated or known te...

Страница 9: ... those already activated all other not activated values will be displayed with or instead Press the ALARM key again to return the Normal Mode In the High Alarm Mode press the SET key to select the following alarm modes 1 Time alarm hour minute 2 Indoor humidity high alarm 3 Indoor temperature high alarm 4 Outdoor humidity high alarm 5 Outdoor temperature and dew point high alarm 6 Pressure high al...

Страница 10: ...y For example in outdoor temperature display mode when dew point high alarm is triggered DEW POINT icon will flash along with general outdoor alarm icon and high alarm icon flashing telling that the current alarm source is from dew point 5 4 Min Max Mode While in Normal Mode press the MIN MAX key to enter the maximum mode MAX logo and the general Max record will be displayed Press MIN MAX key agai...

Страница 11: ...ls between the units thick walls steel concrete isolating aluminum foil and etc Find a different location for sensors and or receiver See also item transmission range below Interference from other sources e g wireless radio headset speaker etc operating on the same frequency Find a different location for the sensors and or base station Neighbors using electrical devices operation on the same signa...

Страница 12: ... 12 ...

Отзывы: