DR.SCHNEIDER PC SL-003 Скачать руководство пользователя страница 4

 

 

knobs and secure the device using center holes on mounting tab. Be sure 

to install fiber washer. 

 

The S hooks provide for chain mounting or mounting on wire shelving. 

Install overhead blower by using outer holes on mounting tabs. Chains 

and  mounting  hardware  (not  supplied)  must  have  a  minimum  safe 

working load of 15kg. 

 

3.2    Electrical

 

The  SL-003  requires  220VAC/50Hz  or  110VAC/60Hz  for  proper 

operation. The device must be grounded for safe operation. The device 

comes with line cord, without plug. A plug must be installed on the line 

cord  for  operation.  Installation  of  the  plug  must  be  performed  by 

qualified  personnel.  The  color  cord  for  wiring  the  plug  is  as  follows: 

Red-line; Blue-Neutral; Green/Yellow-Ground. 

 

4. OPERATION 

Activate the SL-003 Overhead Ionizing Air Blower by turning FAN 

SPEED  knob  clockwise,  out  of  the  off  position.  The  IONIZATION 
INDICATOR will illuminate to indicate the presence of ionized air. Set 
airflow  as  lights  desired  by  adjusting  FAN  SPEED  knob.  If  light  is 

desired, turn on task by setting LIGHTS switch to the

  on 

(1) position. 

TO clean ion emitter points, rotate POINT CLEANER knob at each air 
outlet  clockwise  to  the  stop  slightly  (approximately  one  turn)  and 
release.

 

 

The time required to neutralize a static charge on an item in the air 

stream  depends  on  fan  speed.  Setting  a  higher  fan  speed  reduces  time 

required to neutralize a static charge. 

 

Содержание SL-003

Страница 1: ...1 INSTRUCTION SL 003 IONIZING AIR BLOWER DR SCHNEIDER PC...

Страница 2: ...an overhead unit designed to provide total coverage for electrostatic problems Please read the instruction manual completely before installing or operating the device This device is equipped with a 3...

Страница 3: ...olyurethane Foam Ion Balance offset voltage 0V 10V It requires no calibration 3 INSTALLATION The SL 003 Ionizing blower should be located 600 to 900mm above work surface with center fan directly above...

Страница 4: ...performed by qualified personnel The color cord for wiring the plug is as follows Red line Blue Neutral Green Yellow Ground 4 OPERATION Activate the SL 003 Overhead Ionizing Air Blower by turning FAN...

Страница 5: ...the point cleaners The SL 003 also contains a balancing circuit that is inherently self balancing This circuit compensates for emitter point wear line voltage fluctuations and variations in air veloci...

Страница 6: ...ures are subject to the variation in the atmospheric conditions 4 Discharge times are in seconds from 1000 volts to 100 volts If a charged plate monitor is not available a hand held electrostatic fiel...

Страница 7: ...not insert objects through intake or outlet grille Do not try to verify operation of unit by drawing a spark from an ion emitter point The design of the balancing circuit makes the park test inconclu...

Страница 8: ...r flickers the compact fluorescent lamp should be replaced as soon as possible Access to lamp is provided by removing the front panel of the device Disconnect the device by unplugging line cord Remove...