![DR.SCHNEIDER PC SL-003 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/dr-schneider-pc/sl-003/sl-003_instruction_2526264004.webp)
4
knobs and secure the device using center holes on mounting tab. Be sure
to install fiber washer.
The S hooks provide for chain mounting or mounting on wire shelving.
Install overhead blower by using outer holes on mounting tabs. Chains
and mounting hardware (not supplied) must have a minimum safe
working load of 15kg.
3.2 Electrical
The SL-003 requires 220VAC/50Hz or 110VAC/60Hz for proper
operation. The device must be grounded for safe operation. The device
comes with line cord, without plug. A plug must be installed on the line
cord for operation. Installation of the plug must be performed by
qualified personnel. The color cord for wiring the plug is as follows:
Red-line; Blue-Neutral; Green/Yellow-Ground.
4. OPERATION
Activate the SL-003 Overhead Ionizing Air Blower by turning FAN
SPEED knob clockwise, out of the off position. The IONIZATION
INDICATOR will illuminate to indicate the presence of ionized air. Set
airflow as lights desired by adjusting FAN SPEED knob. If light is
desired, turn on task by setting LIGHTS switch to the
on
(1) position.
TO clean ion emitter points, rotate POINT CLEANER knob at each air
outlet clockwise to the stop slightly (approximately one turn) and
release.
The time required to neutralize a static charge on an item in the air
stream depends on fan speed. Setting a higher fan speed reduces time
required to neutralize a static charge.