Troubleshooting Checklist 

 

In this example, we’ll be using the T/Mon to Telnet to a DMS10 switch to extract the 
ASCII alarm information. 

 
First we need to set up two very general rules for the T/Mon to capture all the data being 
received by the DMS10.  Keep in mind that these settings will be changed after we are done 
verifying a connection to the ASCII device. 
 

1.

 

Go to the Master Menu and select ‘Files’, ‘ASCII Devices’, then ‘Rules’. 

a.

 

Give your rule a name (8 characters max) and hit <ENTER>. Start on rule 0, then 
hit <ENTER> again.  Give the rule a description, go down to the Line Terminator 
Field, then hit <TAB>. Select LF for Line Feed.  Keep hitting <ENTER> until at 
the end of the page. 

 

 

Fig. 1 – Setting up ASCII Rule 0 

 

b.

 

Hit ‘F’ for Find and go to rule 20. Hit (Y)es to create this rule.  Press <ENTER> 
through the default settings. When you reach Pattern Recognition and Action 
Extraction, enter “/M~AL”.  

(These steps are just temporary so that when we are 

ready, we can put T/Mon in Monitor Mode and record all the ASCII text to a log 
file.  We will discuss the many different commands that can be used to parse 
ASCII text after we verify a data connection.)

 

 

Содержание T/Mon NOC

Страница 1: ...ree form non standard and may say almost anything This Techno Knowledge Paper can help you if You are setting up ASCII on T Mon for the first time _____________________________________________________...

Страница 2: ...es a Give your rule a name 8 characters max and hit ENTER Start on rule 0 then hit ENTER again Give the rule a description go down to the Line Terminator Field then hit TAB Select LF for Line Feed Kee...

Страница 3: ...3 Hit E for Edit and then TAB to select an ASCII INPUT job Hit ENTER Fig 3 Create ASCII Input job 4 4 Here you will enter in a port description For a full description of ASCII port connection options...

Страница 4: ...ASCII Input Job 5 You will notice No Data Connection is blinking at the top Hit F6 for Data Connection then F1 for TCP Ports Fig 5 Hit F1 to go to the TCP Port assignment screen 6 This step is where...

Страница 5: ...device listens e The job number to the right will initially be 0 Don t worry this number will change when we assign it to the job When your cursor is at the beginning of the next line hit F8 to save...

Страница 6: ...be receiving alarms from you can have up to 999 sites per ASCII device 9 Now ESC out to the Main Menu Go to Initialize and choose Monitor Mode a From the Alarm Summary Screen hit CTRL F7 to go to the...

Страница 7: ...your T Mon or viewed directly on the system To view it directly on the system escape out of Monitor Mode and go to Files Utilities Report Maintenance Hit TAB to select the file discussed in Step 5 Fi...

Отзывы: