DPS Telecom DAC-P Скачать руководство пользователя страница 43

Warranty

DPS Telecom warrants, to the original purchaser only, that its products a) substantially conform to DPS' published
specifications and b) are substantially free from defects in material and workmanship. This warranty expires two years from
the date of product delivery with respect to hardware and ninety days from the date of product delivery with respect to
software. If the purchaser discovers within these periods a failure of the product to substantially conform to the specifications
or that the product is not substantially free from defects in material and workmanship, the purchaser must promply notify
DPS. Within reasonable time after notification, DPS will endeavor to correct any substantial non-conformance with the
specifications or substantial defects in material and workmanship, with new or used replacement parts. All warranty service
will be performed at the company's office in Fresno, California, at no charge to the purchaser, other than the cost of shipping
to and from DPS, which shall be the responsiblity of the purchaser. If DPS is unable to repair the product to conform to the
warranty, DPS will provide at its option one of the following: a replacement product or a refund of the purchase price for the
non-conforming product. These remedies are the purchaser's only remedies for breach of warranty. Prior to initial use the
purchaser shall have determined the suitability of the product for its intended use. DPS does not warrant a) any product,
components or parts not manufactured by DPS, b) defects caused by the purchaser's failure to provide a suitable installation
environment for the product, c) damage caused by use of the product for purposes other than those for which it was designed,
d) damage caused by disasters such as fire, flood, wind or lightning unless and to the extent that the product specification
provides for resistance to a defined disaster, e) damage caused by unauthorized attachments or modifications, f) damage
during shipment from the purchaser to DPS, or g) any abuse or misuse by the purchaser.

THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE.

In no event will DPS be liable for any special, incidental, or consequential damages based on breach of warranty, breach of
contract, negligence, strict tort, or any other legal theory. Damages that DPS will not be responsible for include but are not
limited to, loss of profits; loss of savings or revenue; loss of use of the product or any associated equipment; cost of capital;
cost of any substitute equipment, facilities or services; downtime; claims of third parties including customers; and injury to
property.

The purchaser shall fill out the requested information on the Product Warranty Card and mail the card to DPS. This card
provides information that helps DPS make product improvements and develop new products.

For an additional fee DPS may, at its option, make available by written agreement only an extended warranty providing an
additional period of time for the applicability of the standard warranty.

Technical Support

If a purchaser believes that a product is not operating in substantial conformance with DPS' published specifications or there
appear to be defects in material and workmanship, the purchaser should contact our technical support representatives. If the
problem cannot be corrected over the telephone and the product and problem are covered by the warranty, the technical
support representative will authorize the return of the product for service and provide shipping information. If the product is
out of warranty, repair charges will be quoted. All non-warranty repairs receive a 90-day warranty.

Содержание DAC-P

Страница 1: ...USER MANUAL DAC P February 13 2003 D OC UM032 13200 Firmware Version 1 0D Your Partners in Network Alarm Management Visit our website at www dpstelecom com for the latest PDF manual and FAQs...

Страница 2: ...vative work by either mechanical electronic or any other means in whole or in part without prior written consent from DPS Telecom except as required by United States copyright laws The material in thi...

Страница 3: ...ns 5 4 7 Configuration 6 8 Craft Port 6 1 8 Terminal Interface 6 2 9 Assigning an IP Address 6 3 10 Configuration File 6 4 11 Uploading the Configuration File 6 5 12 Other Configuration Options 6 6 13...

Страница 4: ...Dial RTU 7 4 26 Reboot RTU 7 5 28 Other Commands 8 29 Ping 8 1 29 Stats 8 2 30 Debug 8 3 31 Unused Commands 8 4 32 LCD Display and Menu 9 32 Front Panel LED Operation 10 32 Technical Support 11 33...

Страница 5: ...t commands from the NTP to remotes These control functions plus alarm monitoring are accessible remotely over a LAN WAN connection or locally through a craft port connection The DAC P channels are pro...

Страница 6: ...B 12003 00001 D PR 045 10A 04 DB9 to Open End Cable Telephone Cable 6 ft D PR 652 10A 06 D PR 045 10A 01 Ethernet Cable DAC P User Manual D OC UM032 13200 23 Rack Ears 19 Rack Ears Eight 3 8 Ear Screw...

Страница 7: ...lines The dial up connection between the DAC P and its remotes is two way either the DAC P can initiate a call to poll a remote or a remote can initiate a call to report an alarm The remote will call...

Страница 8: ...ntrol Commands Report Data To NTP When Polled Collect Data Since the station address may be unknown the DAC P will ascertain the unit s ID by sending a command to address 0 Fig 2 DAC P Operations Flow...

Страница 9: ...al attempts before fallback to three attempts g Set primary phone number h Set backup phone number i Set all other phone number fields to none 5 Send pending relay control commands 6 If reboot request...

Страница 10: ...e bare wire Repeat for power source B if you have dual power inputs 4 Push the plug firmly back into its socket Note that this connection is keyed and the plug must be properly aligned within the sock...

Страница 11: ...sing the provided cable connect these ports to the DPS Telecom Dial Up Converter Shelf Pinouts for data ports 1 4 are shown below in Figure 5 1 2 3 4 5 TX RX GND 6 7 8 9 DCD DTR DAC P DB9 212 Dial Up...

Страница 12: ...r some initial configuration must be done locally before you can access the DAC P through a network connection To make a local connection to the DAC P connect a DB9 serial cable from the COM port of y...

Страница 13: ...re 8 To choose a command press the key for the letter before or within the parenthesis For example to select the C onfig menu from the main menu press C To e X it the terminal interface press X To qui...

Страница 14: ...t for instructions Choose C onfig E dit E thernet The screen will display the current IP configuration and a menu for editing IP configuration See Figure 10 above You must assign the DAC P a unit IP a...

Страница 15: ...field Fig 12 Elements of an ADDR_CFG entry The ADDR_CFG section defines which remotes the DAC P will poll what type of device the remote is and to which MEFA to map the device Valid entries for the a...

Страница 16: ...e No sections should appear below this tag Do not put this tag between sections Uploading the Configuration File 6 5 Fig 14 Uploading the configuration file The configuration file must be uploaded to...

Страница 17: ...boot See Section 6 6 1 3 Cycle power to the DAC P unit 4 Select the Reboot command from the LCD display menu See Section 9 Other Configuration Options 6 6 More configuration options are available thro...

Страница 18: ...of the password the password itself and the Quiet logon option If you choose to change the Master Password you will be prompted to type the new password once to enter and a second time to confirm If...

Страница 19: ...oose C onfig E dit L ogon A dvanced Up to 16 users can be defined and each can have unique access rights In the example in Figure 17 the user MONITOR is authorized only to access the monitor screens w...

Страница 20: ...Choosing the A ccess command opens a list defining the user s access privileges as shown in Figure 18 Choosing one of the menu commands toggles permission for that item In the example above to add dat...

Страница 21: ...6 3 Timers Fig 19 Timers menu The Timers menu contains commands for editing the alive full update time how long the alarm speaker will sound the RTS head and tail time channel timeout and TABS poll d...

Страница 22: ...ed The C onfig E dit T imers S ound command sets how long the speaker will sound if an alarm condition is detected Choosing this command will open a menu for setting the sound timer period and time un...

Страница 23: ...AC P s internal clock choose C onfig E dit D ate time The available options are to set the date in MM DD YYYY format the day of the week and the time To choose an option to edit press the appropriate...

Страница 24: ...to one option the dial type used by the modem If you choose the M odem command the DAC P will report whether the modem is set for pulse or tone dialing Choosing the T ype command will toggle between p...

Страница 25: ...o save changes to the DAC P s configuration The I nitialize command will erase the NVRAM removing the configuration file and all other configuration information If you choose the I nitialize command a...

Страница 26: ...or a for each MEFA in the format in which it will be reported to the NTP If you choose the M efas command a prompt will ask you to specify a MEFA range 0 31 The screen will display the data for the fi...

Страница 27: ...d by the DAC P choose C onfig M onitor C onfig list The configuration list consists of two sections the poll list shown in Figure 25 and the phone list shown in Figure 26 The poll list shows the DCP a...

Страница 28: ...red whenever the DAC P reboots or the user clears it To see the alert log choose C onfig M onitor A lert log Each alert message is stamped with the date and time of the event A prompt will ask you if...

Страница 29: ...Address X on Port X at 1200 bps The DAC P has connected to the remote at the indicated baud rate Failed Multiple Poll Attempts to RTU Address X from Port X The call was made but communication was unsu...

Страница 30: ...RTU 7 4 Fig 27 A successful call to an RTU The C onfig M onitor D ial RTU command initiates a call to a remote If you choose this command you will be prompted to enter the MEFA of the remote you want...

Страница 31: ...itiate communication with the remote you will see a screen like Figure 28 Note After a call to an RTU has been initiated pressing the Esc key will exit to the Monitor menu but it will not cancel the c...

Страница 32: ...and If you choose this command you will be prompted to enter the MEFA of the remote you want to reboot A successful reboot will look like Figure 29 above Note After sending a reboot command pressing t...

Страница 33: ...0 Ping command The C onfig P ing command pings IP addresses on your network If you choose this command you will be prompted to enter the IP address you want to ping A successful ping will look like Fi...

Страница 34: ...30 Stats 8 2 Fig 31 Stats command The C onfig S tats command displays a list of system statistics as shown in Figure 31...

Страница 35: ...rn off all filters press X The MEFA filter isolates communication with with remote devices You can see communication traffic with either one MEFA or all MEFAs The communication filters are DCP Display...

Страница 36: ...ding the front panel LCD display are used to access the LCD display menu To access the menu press the MENU button To scroll the menu use the and buttons To select a menu command press the SEL button S...

Страница 37: ...portant information about your DPS Telecom product in hand when you call will greatly reduce the time it takes to answer your questions If you do not have all of the information when you call our Tech...

Страница 38: ...nfig E dit L ogon M inimum password 14 C onfig E dit L ogon P assword 14 C onfig E dit L ogon Q uiet logon 14 C onfig E dit M odem 20 C onfig E dit n V ram 21 C onfig E dit n V ram I nitialize 21 C on...

Страница 39: ...subnet mask 10 configuration file 1 3 11 23 24 uploading 11 craft port 8 current draw 3 DAC P 1 13 primary contact person 13 unit location 13 unit name 13 DCP address 11 23 debug 31 filters 31 dimensi...

Страница 40: ...lt password 9 Master 14 password length 14 users 14 phone list 23 phone numbers 3 11 23 backup 3 11 23 outbound 11 outgoing 23 primary 3 11 23 poll list 23 power input 3 6 rack ears 1 6 redial 3 attem...

Страница 41: ...TABS 1 7 ports 7 responder 1 technical support 33 Telnet 9 Unix client 9 terminal interface 9 commands 9 menus 9 TMAS database 1 11 users 14 access rights 14 creating a user 14 deleting a user 14...

Страница 42: ......

Страница 43: ...lightning unless and to the extent that the product specification provides for resistance to a defined disaster e damage caused by unauthorized attachments or modifications f damage during shipment f...

Страница 44: ...le Fresno CA 93727 559 454 1600 800 622 3314 559 454 1688 fax Your Partners in Network Alarm Management Dependable Powerful Solutions that allow users to monitor larger more complicated networks with...

Отзывы: